ELITE PROPERTIES OF AMERICA, INC. | B= | C | 07/09/2018 | | BOBF | BOBF | | B= | C | 5896495 |
ELITE PROPERTIES OF AMERICA, INC. | BLA | C | 05/25/2018 | Lath ok | TIMOTHYS | TIMOTHYS | | BLA | C | 5855989 |
ELITE PROPERTIES OF AMERICA, INC. | BLA | R | 05/23/2018 | not ready | BOBF | BOBF | | BLA | R | 5853409 |
ELITE PROPERTIES OF AMERICA, INC. | BIN | C | 05/14/2018 | | BOBF | BOBF | | BIN | C | 5844241 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | C | 05/14/2018 | | BOBF | BOBF | | BFR | C | 5844233 |
ELITE PROPERTIES OF AMERICA, INC. | BTR | C | 05/11/2018 | | BOBF | BOBF | | BTR | C | 5842439 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | P | 05/10/2018 | post supporting steel beam in basement to be treated lumber bearing on foundation / okay to insulate | BOBF | BOBF | | BFR | P | 5841095 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 05/09/2018 | 3 deck piers OK -- Deck frame OK | DAKOTAB | DAKOTAB | | BSP | P | 5840207 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 05/09/2018 | Verification of under drain tie in on file | DAKOTAB | DAKOTAB | | BSP | P | 5839497 |
ELITE PROPERTIES OF AMERICA, INC. | BFD | C | 05/09/2018 | Engineer letter for perimeter drain on file -- Damp proofing noted -- Open hole on file -- 2400 PSF - Drain usable - 5% | DAKOTAB | DAKOTAB | | BFD | C | 5839495 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 05/09/2018 | Foundation design on file | DAKOTAB | DAKOTAB | | BSP | P | 5839493 |
ELITE PROPERTIES OF AMERICA, INC. | BFN | C | 05/09/2018 | Engineer letter for foundation on file -- Eufer noted | DAKOTAB | DAKOTAB | | BFN | C | 5839490 |
ELITE PROPERTIES OF AMERICA, INC. | BFT | P | 04/30/2018 | letter for footing on file, still need open hole and design | BOBF | BOBF | | BFT | P | 5830365 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 04/19/2018 | need to complete all required foundation inspections / front porch with posts okay / rear porch trusses okay, post not installed / garage portal wall okay / need address posted on house so it is visable from street | BOBF | BOBF | | BSP | P | 5821494 |
J2D ELECTRIC, INC. | E= | C | 07/02/2018 | a/c installed | BRET | BRET | | E= | C | 5891706 |
J2D ELECTRIC, INC. | ES | C | 05/07/2018 | Residential Underground: 200 amp service new res | BRET | BRET | | ES | C | 5837745 |
J2D ELECTRIC, INC. | EUG | C | 05/07/2018 | 4/0-4/0-4/0 | BRET | BRET | | EUG | C | 5837744 |
J2D ELECTRIC, INC. | ER | C | 05/01/2018 | #8 al x4 no mcc,no vac. ir ufer | BRET | BRET | | ER | C | 5832707 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 07/02/2018 | NOTES: PARTIALLY FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C COMPLETE | BENH | BENH | | H= | C | 5891633 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | P | 06/26/2018 | CONDENSER IS LEANING AWAY FROM HOUSE, NEEDS TO BE LEVELED, NEED FIREPLACE INSTALLATION INSTRUCTIONS FOR MANTLE CLEARANCES NOTES: PARTIALLY FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, OUTSIDE AIR TO RETURN, A/C COMPLETE | BENH | BENH | | H= | P | 5886100 |
KAMPP-L ENTERPRISES, INC. | HC | C | 05/09/2018 | RELEASE METER | BENH | BENH | | HC | C | 5840333 |
KAMPP-L ENTERPRISES, INC. | HI | C | 05/09/2018 | 10 LB TEST OK, 1 1/4" MAIN, 1 FURNACE, 1 WATER HEATER, 1 FIREPLACE, 1 COOK TOP, 1 PATIO | BENH | BENH | | HI | C | 5840329 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 05/04/2018 | CORRECTIONS MADE, SEE IMAGES | BENH | BENH | | HRR | C | 5835673 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 05/02/2018 | APPEARS PVC VENT IS WITHIN 18" OF VALLEY, CONTRACTOR TO VERIFY WITH PICTURE OF DISTANCE FROM VALLEY NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C ROUGH COIL AND LINE SET | BENH | BENH | | HRR | P | 5833748 |
KAMPP-L ENTERPRISES, INC. | P= | C | 07/06/2018 | | TAYLOR | TAYLOR | | P= | C | 5895290 |
KAMPP-L ENTERPRISES, INC. | P= | P | 07/03/2018 | crossed water lines at hall bathtub, loose shower arm at master, cap rough in drains for toilet/ tub in basement, need power supply for recirculating pump, rest ok, pvb installed, finished basement ( 1 bathroom only ). | TAYLOR | TAYLOR | | P= | P | 5892614 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 05/01/2018 | Finished basement, irrigation | SHANEN | SHANEN | | PTO | C | 5832244 |
KAMPP-L ENTERPRISES, INC. | PB | C | 04/03/2018 | | SHANEN | SHANEN | | PB | C | 5806463 |