ELITE PROPERTIES OF AMERICA, INC. | B= | C | 07/20/2018 | corrections okay | BRIANB | BRIANB | | B= | C | 5909165 |
ELITE PROPERTIES OF AMERICA, INC. | B= | P | 07/18/2018 | front basement bedroom window well does not meet minimum horizontal projection of 36"/also missing egress ladder -- partial finished basement/no deck -- Schedule a new Building Final when above items are complete. | SCOTTS | SCOTTS | | B= | P | 5906311 |
ELITE PROPERTIES OF AMERICA, INC. | BIN | C | 05/10/2018 | | SCOTTS | SCOTTS | | BIN | C | 5841800 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | C | 05/10/2018 | correction complete | SCOTTS | SCOTTS | | BFR | C | 5841799 |
ELITE PROPERTIES OF AMERICA, INC. | BIN | P | 05/09/2018 | complete BFR | SCOTTS | SCOTTS | | BIN | P | 5840076 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | P | 05/09/2018 | nails in HUS and HGUS not correct still | SCOTTS | SCOTTS | | BFR | P | 5840075 |
ELITE PROPERTIES OF AMERICA, INC. | BLA | C | 05/09/2018 | | SCOTTS | SCOTTS | | BLA | C | 5840074 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | R | 05/07/2018 | not dried in/missing roof jacks -- 16d in HGUS and HUS -- missing 2nd king each side of middle optional window left elevation | SCOTTS | SCOTTS | | BFR | R | 5837806 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 05/02/2018 | shear and porch corrections complete | SCOTTS | SCOTTS | | BSP | P | 5833696 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | R | 04/19/2018 | post caps on rear work in pairs -- shear incomplete at this time/nail down sill plates per schedule/install drag struts/ complete nailing on sheathing other than garage rear wall | SCOTTS | SCOTTS | | BSP | R | 5821693 |
ELITE PROPERTIES OF AMERICA, INC. | BFD | C | 04/02/2018 | drain tie in on file | SCOTTS | SCOTTS | | BFD | C | 5804586 |
ELITE PROPERTIES OF AMERICA, INC. | BFN | C | 03/30/2018 | foundation observation and design on file | SCOTTS | SCOTTS | | BFN | C | 5803347 |
ELITE PROPERTIES OF AMERICA, INC. | BFD | P | 03/30/2018 | Pending verification of connection to underdrain via photo or reinspection -- drain observation on file-- soils/open ex on file -- over ex observation on file | SCOTTS | SCOTTS | | BFD | P | 5803346 |
ELITE PROPERTIES OF AMERICA, INC. | BFT | C | 03/30/2018 | footing observation on file | SCOTTS | SCOTTS | | BFT | C | 5803341 |
ELITE PROPERTIES OF AMERICA, INC. | BFT | P | 02/15/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5766327 |
ELITE PROPERTIES OF AMERICA, INC. | BFD | P | 02/15/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 5766328 |
ELITE PROPERTIES OF AMERICA, INC. | BFN | P | 02/15/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5766326 |
J2D ELECTRIC, INC. | E= | C | 06/26/2018 | 40 amp a/c | RANDY | RANDY | | E= | C | 5886258 |
J2D ELECTRIC, INC. | ES | C | 05/03/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / Irreversible UFER connection / | TOMC | TOMC | | ES | C | 5835135 |
J2D ELECTRIC, INC. | ER | C | 05/03/2018 | 200 ---- 3 - #8 , no mcc , no central vac , irreversible ufer , finished basement | TOMC | TOMC | | ER | C | 5835132 |
OAK VIEW INVESTMENTS, LLC | H= | C | 06/18/2018 | Notes-- Finished basement. AC complete. Direct vent furnace. Outside air to return. | JEFFL | JEFFL | | H= | C | 5877714 |
OAK VIEW INVESTMENTS, LLC | HC | C | 05/04/2018 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5836800 |
OAK VIEW INVESTMENTS, LLC | HRR | C | 05/04/2018 | Notes-- AC rough... Outside air to return. Finished basement. | JEFFL | JEFFL | | HRR | C | 5836793 |
OAK VIEW INVESTMENTS, LLC | HRR | P | 05/03/2018 | Duct design does not match home, need revised/approved plans. BY FINAL: Water heater to obtain 30" clearance (rotate). NOTES: Finished basement. Direct vent furnace. A/C Rough coil and line-set. NO outside air to furnace return. | RANDYB | RANDYB | | HRR | P | 5834888 |
PRECISION PLUMBING | HI | C | 05/02/2018 | 10 LB test ok. 1 1/4" Main. 1- furnace, 1- water heater, 1- range, 1- fireplace. 1- dryer, 1- BBQ | DUSTINS | DUSTINS | | HI | C | 5834286 |
PRECISION PLUMBING | P= | C | 07/17/2018 | correction made | TED | TED | | P= | C | 5905016 |
PRECISION PLUMBING | P= | R | 07/16/2018 | master bath shower arm 90 still loose in wall, will need 3rd trip, waive trip fee this time | TED | TED | | P= | R | 5903829 |
PRECISION PLUMBING | P= | R | 07/13/2018 | hall bath tub valve water crossed, master bath shower arm 90 loose in wall, note: finished basement, 3/4'' pvb installed | TED | TED | | P= | R | 5902384 |
PRECISION PLUMBING | PTO | C | 05/02/2018 | finished basement, bar sink vtr, tempering valve in master closet, sprinkler stub | TED | TED | | PTO | C | 5833973 |
PRECISION PLUMBING | PB | C | 04/05/2018 | ok, water under footer | TED | TED | | PB | C | 5809231 |