HOMEOWNER | BE | L | 01/19/2021 | Renewed for $50.00 at 1/19/2021 3:40:02 PM (Receipt#1743961) | RITA | RITA | | BE | L | 6840797 |
HOMEOWNER | B= | P | 06/16/2020 | Front deck / No basement / AC installed. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | TIMOTHYS | TIMOTHYS | | B= | P | 6605870 |
HOMEOWNER | BSP | P | 03/13/2020 | Deck frame OK | NICK | NICK | | BSP | P | 6510409 |
HOMEOWNER | BIN | C | 10/02/2019 | All insulation OK | NICK | NICK | | BIN | C | 6354972 |
HOMEOWNER | BFR | C | 10/02/2019 | All framing items completed / Still need to inspect deck frame per splice | NICK | NICK | | BFR | C | 6354971 |
HOMEOWNER | BFN | C | 10/02/2019 | | NICK | NICK | | BFN | C | 6354966 |
HOMEOWNER | BFT | C | 10/02/2019 | Soils report on file | NICK | NICK | | BFT | C | 6354961 |
HOMEOWNER | BFR | P | 08/29/2019 | Need to splice plans for new trusses installed / Need to install double king studs for master bed room header / Need to remove screws from post base and caps in crawl space and install nails or simpson screws / Need to glue shims in beam pockets in crawl space / Need soils report / OK to insulate / Exterior porch frame OK | NICK | NICK | | BFR | P | 6318570 |
HOMEOWNER | BFD | C | 08/29/2019 | 3rd party observation on file | NICK | NICK | | BFD | C | 6318564 |
HOMEOWNER | BFN | P | 08/29/2019 | 3rd party observation on file / Grounding rod observed / Need soils report | NICK | NICK | | BFN | P | 6318563 |
HOMEOWNER | BFT | P | 08/29/2019 | 3rd party observation on file for drilled pier observation / Need soils report referenced in observation report | NICK | NICK | | BFT | P | 6318560 |
HOMEOWNER | BE | C | 01/16/2019 | | TERRI | TERRI | | BE | C | 6079481 |
HOMEOWNER | BE | C | 08/01/2018 | | JESSICAM | JESSICAM | | BE | C | 5920100 |
HOMEOWNER | E= | C | 06/11/2020 | pics accepted, | JOHNN | JOHNN | | E= | C | 6600888 |
HOMEOWNER | E= | R | 06/10/2020 | need 15 amp max cb on a/c, has 20 amp/ need gfci on crawler lights/ | JOHNN | JOHNN | | E= | R | 6599462 |
HOMEOWNER | E= | R | 05/14/2020 | strap riser at soffit/ label panel/may need some afci cb's/ all outlets in launrdy rm need gfci/ dishwaher needs af gf cb/ crawler: staple nm cable every 4 1/2'/ furnace needs nm connector/ label on,off on disco/ crawler lights need a guard and gfci/ notes: no a/c, | JOHNN | JOHNN | | E= | R | 6571552 |
HOMEOWNER | ES | C | 05/14/2020 | Residential Overhead: 200-amp 3 Wire New Residence, no action needed, | JOHNN | JOHNN | | ES | C | 6571551 |
HOMEOWNER | ER | C | 07/23/2019 | | GARYL | GARYL | | ER | C | 6274329 |
HOMEOWNER | ES | P | 07/19/2019 | Residential Overhead: 200-amp 3 Wire New Residence ok to set meter. / -----------------------check for cold water grd. | JOHNN | JOHNN | | ES | P | 6270429 |
HOMEOWNER | ER | R | 07/19/2019 | add travelers for 3 way. | JOHNN | JOHNN | | ER | R | 6270427 |
HOMEOWNER | ER | R | 07/12/2019 | add 2 outlets per counter spacing req, change bath rm circuits to meet code, missed 3 way, add outlet on porch,grd pancake box with green grd screw, wire bath fan, seal panel nipple, trim attic, | JOHNN | JOHNN | | ER | R | 6261987 |
HOMEOWNER | ES | R | 07/12/2019 | Residential Overhead: 200 amp 3w, HO to consult with CSU which pole they will use, may change riser location, may need guy wire, cold water not in yet, CHECK on final, rev ufer in crawler,ok | JOHNN | JOHNN | | ES | R | 6261975 |
HOMEOWNER | H= | C | 06/10/2020 | PERMIT SECURED PRIOR TO JANUARY 1 2020 NOTE/ CONDITIONED CRAWLSPACE/ DIRECT VENT FURNACE/ A/C COMPLETE | DAVIDH | DAVIDH | | H= | C | 6599544 |
HOMEOWNER | HC | C | 08/28/2019 | RELEASE METER | BILLS | BILLS | | HC | C | 6317461 |
HOMEOWNER | HRR | C | 08/28/2019 | BY FINAL: CONDITION THE CRAWLSPACE, INTERLOCK CONDENSATE PUMP, PROVIDE MAKE-UP AIR TO DRYER, FURNACE SIDEWALL KIT TO TERMINATE 12" ABOVE GRADE. NOTES: CONDITIONED CRAWLSPACE (2 SUPPLY), OUTSIDE AIR TO FURNACE RETURN, 4" HIGH COMBUSTION AIR TO WATER HEATER CLOSET, DIRECT VENT FURNACE, A/C ROUGH COIL, NO FIREPLACE | BILLS | BILLS | | HRR | C | 6317460 |
HOMEOWNER | HI | C | 08/27/2019 | | MATTM | MATTM | | HI | C | 6316161 |
HOMEOWNER | HRR | P | 08/27/2019 | WATER HEATER VENT NEEDS TO TERMINATE 3FT ABOVE WATER HEATER COMBUSTION AIR INLET. BY FINAL: CONDITION THE CRAWLSPACE, INTERLOCK CONDENSATE PUMP, PROVIDE MAKE-UP AIR TO DRYER, FURNACE SIDEWALL KIT TO TERMINATE 12" ABOVE GRADE. NOTES: CONDITIONED CRAWLSPACE (2 SUPPLY), OUTSIDE AIR TO FURNACE RETURN, 4" HIGH COMBUSTION AIR TO WATER HEATER CLOSET, DIRECT VENT FURNACE, A/C ROUGH COIL, NO FIREPLACE | MATTM | MATTM | | HRR | P | 6316135 |
HOMEOWNER | HRR | P | 05/08/2019 | DUCT DESIGN DOES NOT MATCH PLANS, HOMEOWNER WILL NEED TO SUBMIT A NEW DUCT DESIGN FOR APPROVAL AND ATTACH NEW DUCT DESIGN TO PERMIT AS A SPLICE, OUTSIDE AIR TO FURNACE RETURN NEEDS TO BE 12" ABOVE GRADE AND CANNOT BE WITHIN 10FT OF FURNACE EXHAUST, FURNACE SIDE WALL KIT MUST BE 12" ABOVE GRADE, SUPPORT FURNACE VENT/INTAKE PIPES EVERY 3 TO 5 FEET, ALL DUCT NEEDS TO BE SEALED IN CRAWLSPACE, ALL ROUND SUPPLY DUCT NEEDS TO BE MECHANICALLY FASTENED WITH 3 SCREWS MINIMUM, DRYER DUCT MUST BE 26 GAUGE MINIMUM, MISSING DRYER NAIL PROTECTION, CANNOT CONCEAL VINYL TUBING, MISSING INSULATION SHIELD FOR WATER HEATER VENT, INSTALL IINSULATION SHIELD PER THE 2009 IFGC SECTION 502.4, WATER HEATER VENT NEEDS TO TERMINATE 3FT ABOVE OR 10FT FROM WATER HEATER HIGH COMBUSTION AIR INLET, BY FINAL: CONDITION THE CRAWLSPACE, INTERLOCK CONDENSATE PUMP, PROVIDE MAKE-UP AIR TO DRYER NOTES: CONDITIONED CRAWLSPACE (2 SUPPLY), OUTSIDE AIR TO FURNACE RETURN, 4" HIGH COMBUSTION AIR TO WATER HEATER CLOSET, DIRECT VENT FURNACE, A/C ROUGH COIL, NO FIREPLACE | MATTM | MATTM | | HRR | P | 6192712 |
HOMEOWNER | HI | P | 05/08/2019 | CAP OR COMPLETE GAS PIPE TO WATER HEATER, SUPPORT GAS PIPE EVERY 8FT MAXIMUM 10LB TEST OK 1" MAIN 1 FURNACE 1 WATER HEATER | MATTM | MATTM | | HI | P | 6192667 |
HOMEOWNER | P= | C | 06/11/2020 | Corrections made. | SAMH | SAMH | | P= | C | 6600761 |
HOMEOWNER | P= | P | 06/10/2020 | Need air gap at dishwasher. | SAMH | SAMH | | P= | P | 6600049 |
HOMEOWNER | P= | P | 05/14/2020 | Pipe water heater pan to floor drain. complete tub trim and seal to wall. Need air gap and shock arrester at dishwasher. Need trap guard at laundry floor drain. | SAMH | SAMH | | P= | P | 6571561 |
HOMEOWNER | PTO | C | 05/24/2019 | correction made | JOSEPHD | JOSEPHD | | PTO | C | 6209747 |
HOMEOWNER | PTO | P | 05/17/2019 | water pipe ok | JOSEPHD | JOSEPHD | | PTO | P | 6202505 |
HOMEOWNER | P16 | C | 05/17/2019 | discussed water pipe sizing | JOSEPHD | JOSEPHD | | P16 | C | 6202498 |
HOMEOWNER | PTO | P | 05/02/2019 | water pipe under sized, need boca plates at top and bottom of walls, note: vents capped on roof, no irrigation, check water heater at final | JOSEPHD | JOSEPHD | | PTO | P | 6184881 |
HOMEOWNER | XBS | T | 09/20/2019 | PAID (REC#1631574) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Added decks to scope. | BPHILLIPS | BPHILLIPS | | XBS | T | 6342375 |
HOMEOWNER | XMS | P | 08/26/2019 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised manual D and associated manual J sheets for duct size revisions | JUSTINC | JUSTINC | | XMS | P | 6314242 |