TRALON HOMES, LLC | B= | C | 06/11/2018 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 5870991 |
TRALON HOMES, LLC | B= | P | 06/08/2018 | No deck / AC installed / Basement finish under separate permit. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | JUSTINL | JUSTINL | | B= | P | 5869458 |
TRALON HOMES, LLC | BSP | P | 05/07/2018 | front porch posts and lid OK | LONNYS | LONNYS | | BSP | P | 5837776 |
TRALON HOMES, LLC | BIN | C | 04/19/2018 | Contractor provided verification of correction - Insulation OK - Will inspect front porch posts as BSP at later date | JUSTINL | JUSTINL | | BIN | C | 5821736 |
TRALON HOMES, LLC | BIN | R | 04/19/2018 | Insulation correction not complete | JUSTINL | JUSTINL | | BIN | R | 5821583 |
TRALON HOMES, LLC | BFR | C | 04/19/2018 | Frame correction complete - Will inspect front porch posts at later date as BSP / Basement finish under separate permit ( L44206 ) | JUSTINL | JUSTINL | | BFR | C | 5821572 |
TRALON HOMES, LLC | BIN | R | 04/18/2018 | Complete frame / Missing insulation at exterior wall under main level landing | JUSTINL | JUSTINL | | BIN | R | 5820415 |
TRALON HOMES, LLC | BFR | P | 04/18/2018 | Address item 7 / other frame corrections complete - Still need to inspect front porch posts | JUSTINL | JUSTINL | | BFR | P | 5820412 |
TRALON HOMES, LLC | BFR | P | 04/16/2018 | 1. Strap King studs on EE of garage door / 2. Missing (2) H2.5 at TR18 mid point / 3. Strap (7) 2x post under TR2 / 4. Finish nailing Plumbing shoes in master bath / 5. Missing 3rd king EE of windows above entry door / 6. Missing solid blocking at Study cantilever / 7. Remove wood from beam pockets // Rear porch post and lid OK / Front porch lid OK - Still need to inspect front porch posts / Plans reviewed electronically | JUSTINL | JUSTINL | | BFR | P | 5817999 |
TRALON HOMES, LLC | BFD | C | 03/16/2018 | | JUSTINL | JUSTINL | | BFD | C | 5790665 |
TRALON HOMES, LLC | BSP | P | 03/16/2018 | Foundation design | JUSTINL | JUSTINL | | BSP | P | 5790664 |
TRALON HOMES, LLC | BFN | C | 03/16/2018 | Engineer letter for foundation -- Eufer noted / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5790663 |
TRALON HOMES, LLC | BFT | C | 03/16/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF ( Verified ) / Drain usable / 10% | JUSTINL | JUSTINL | | BFT | C | 5790661 |
TRALON HOMES, LLC | BFD | P | 03/15/2018 | Drain entire and usable to sump pit pending verification of connection to underdrain via photo or reinspection / / Damp proof OK / Request all foundation paperwork | JUSTINL | JUSTINL | | BFD | P | 5790081 |
TRALON HOMES, LLC | BFT | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFT | P | 5767480 |
TRALON HOMES, LLC | BFN | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFN | P | 5767479 |
J2D ELECTRIC, INC. | E= | C | 06/06/2018 | a/c installed--30 amp | TIMA | TIMA | | E= | C | 5866170 |
J2D ELECTRIC, INC. | E= | R | 06/05/2018 | secure furnace disconnect box at strap flex and wire up high, | TIMA | TIMA | | E= | R | 5865037 |
J2D ELECTRIC, INC. | ES | C | 04/26/2018 | Residential Underground: 150 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5828747 |
J2D ELECTRIC, INC. | EUG | C | 04/25/2018 | 2/0 urd | TOMC | TOMC | | EUG | C | 5826920 |
J2D ELECTRIC, INC. | ER | C | 04/11/2018 | #8 AL to oven/range / No Cent Vac / Irreversible UFER connection / Unfinished Basement / | TIMA | TIMA | | ER | C | 5814084 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/04/2018 | | MATTM | MATTM | | H= | C | 5862949 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 06/01/2018 | NEED RETURN AIR PATHWAY AT BASEMENT BEDROOM. NOTE: FINISHED BASEMENT, FULL A/C, OUTSIDE AIR TO RETURN DUCT, LOUVER DOOR AT MECHANICAL ROOM | BILLS | BILLS | | H= | P | 5861954 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/11/2018 | RELEASE METER | MARK | MARK | | HC | C | 5814200 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/11/2018 | Note: Unfinished basement, line set rough only, has osa to return. | MARK | MARK | | HRR | C | 5814191 |
BARRETT PLUMBING, INC. | HI | C | 04/10/2018 | 10 lb test ok. Note: 1" main, furnace and water heater. | MARK | MARK | | HI | C | 5813062 |
KIMBEL MECHANICAL SYSTEMS, INC. | P= | C | 06/07/2018 | | JOHNS | JOHNS | | P= | C | 5867794 |
KIMBEL MECHANICAL SYSTEMS, INC. | P= | P | 06/06/2018 | contractor to verify north east vent glued in attic w/ conformation in comments section of inspection request, rest ok for previous corrections | JOHNS | JOHNS | | P= | P | 5866722 |
KIMBEL MECHANICAL SYSTEMS, INC. | P= | P | 06/01/2018 | contractor to verify north east vent glued in attic w/ conformation in comments section of inspection request, water htr trapped by humidifier, draft divertor not centered over flue exhaust @ water htr, rest ok. note: pvb ok, bsmnt finish permit # L44206 | JOHNS | JOHNS | | P= | P | 5861775 |
KIMBEL MECHANICAL SYSTEMS, INC. | PTO | C | 04/13/2018 | Correction made. | DANR | DANR | | PTO | C | 5817024 |
KIMBEL MECHANICAL SYSTEMS, INC. | PTO | P | 04/06/2018 | Freeze protection garage, nail protection right master lav, rest ok, 4-vtr, tempering valve by water heater, unfinished basement (vtr lav), sprinkler stub. | DANR | DANR | | PTO | P | 5810480 |
KIMBEL MECHANICAL SYSTEMS, INC. | PB | C | 03/21/2018 | Correction made. | DANR | DANR | | PB | C | 5795174 |
KIMBEL MECHANICAL SYSTEMS, INC. | PB | P | 03/20/2018 | 3" main to bathroom by 90 needs re-grade, rest ok. | DANR | DANR | | PB | P | 5794126 |