TRALON HOMES, LLC | B= | C | 06/12/2018 | Previous item complete | RICHB | RICHB | | B= | C | 5872249 |
TRALON HOMES, LLC | B= | P | 06/07/2018 | Need to increase sump discharge pipe length away from foundation and seal around penetration / Other corrections complete -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | JUSTINL | JUSTINL | | B= | P | 5868100 |
TRALON HOMES, LLC | B= | R | 06/04/2018 | 1. Missing frost board at front and rear cantilever / 2. Missing down spout at front porch / 3. Hole in siding at sump pit discharge / 4. Missing steps at rear sliding glass door / 5. Seal around diverter flashing at rear pop out / 6. Missing sump pump and discharge // Finished basement / No deck / No AC. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819), External Agency Inspection UWS by WIDEFIELDWSD is not Completed yet (Contact: Wateropps@wwsdonline.com or 390-7111). | JUSTINL | JUSTINL | | B= | R | 5863374 |
TRALON HOMES, LLC | BIN | C | 06/04/2018 | | JUSTINL | JUSTINL | | BIN | C | 5863373 |
TRALON HOMES, LLC | BFR | C | 06/04/2018 | Engineer letter for hold downs at narrow braced wall on file | JUSTINL | JUSTINL | | BFR | C | 5863370 |
TRALON HOMES, LLC | BSP | P | 05/11/2018 | Engineer letter for Narrow braced wall hold downs on file - No repair needed | JUSTINL | JUSTINL | | BSP | P | 5841976 |
TRALON HOMES, LLC | BIN | P | 04/27/2018 | Insulation OK pending frame | JUSTINL | JUSTINL | | BIN | P | 5829922 |
TRALON HOMES, LLC | BFR | P | 04/27/2018 | Address item 1 / Other frame correction complete | JUSTINL | JUSTINL | | BFR | P | 5829916 |
TRALON HOMES, LLC | BFR | P | 04/25/2018 | 1. address STHD14s at narrow braced wall / 2. Stud spacing greater than 16" OC at laundry room bearing wall / Plans reviewed electronically | JUSTINL | JUSTINL | | BFR | P | 5827377 |
TRALON HOMES, LLC | BSP | P | 04/19/2018 | Engineer letter omitting 3rd car narrow braced wall received - Address STHD14s installed too low at 2 car narrow braced wall / Front porch post and lid OK | JUSTINL | JUSTINL | | BSP | P | 5821714 |
TRALON HOMES, LLC | BSP | R | 04/10/2018 | Narrow braced wall STHD14 installed too low - Nails not secured to framing members - 3rd car sheathing does not meet width ratio - Exterior nailing and interior straps OK | JUSTINL | JUSTINL | | BSP | R | 5813082 |
TRALON HOMES, LLC | BFD | C | 03/28/2018 | | JUSTINL | JUSTINL | | BFD | C | 5800921 |
TRALON HOMES, LLC | BSP | P | 03/28/2018 | Foundation design | JUSTINL | JUSTINL | | BSP | P | 5800919 |
TRALON HOMES, LLC | BFN | C | 03/28/2018 | Engineer letter for foundation -- Eufer noted / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5800917 |
TRALON HOMES, LLC | BFT | C | 03/28/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF ( Verified ) / Drain usable / 10% | JUSTINL | JUSTINL | | BFT | C | 5800915 |
TRALON HOMES, LLC | BFD | P | 03/21/2018 | Drain is usable and entire to sump pit / Damp proof OK / Request all foundation paperwork | JUSTINL | JUSTINL | | BFD | P | 5795360 |
TRALON HOMES, LLC | BFT | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFT | P | 5767488 |
TRALON HOMES, LLC | BFN | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFN | P | 5767487 |
J2D ELECTRIC, INC. | E= | C | 05/25/2018 | a/c pre-wire only | TIMA | TIMA | | E= | C | 5856838 |
J2D ELECTRIC, INC. | ER | C | 04/20/2018 | | TOMC | TOMC | | ER | C | 5822952 |
J2D ELECTRIC, INC. | ES | C | 04/19/2018 | Residential Underground: 150 amp 3/w: new res------------ meter is set | MATTHEW | MATTHEW | | ES | C | 5821803 |
J2D ELECTRIC, INC. | ER | R | 04/19/2018 | land nm in hall light by kitchen, nail plate basement bedroom between closet and door, tighten ground screw in basement bath pan box------------------ finished basement, no mcc's, ir ufer, no vac | MATTHEW | MATTHEW | | ER | R | 5821802 |
J2D ELECTRIC, INC. | EUG | C | 04/09/2018 | | TIMA | TIMA | | EUG | C | 5811350 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 05/25/2018 | | JACK | JACK | | H= | C | 5855808 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 05/24/2018 | Install proper furnace filter in furnace. NOTES: Finished basement. Outside air to furnace return. High low transfers to mechanical room. No A/C. | RANDYB | RANDYB | | H= | P | 5855132 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/23/2018 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5824401 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/23/2018 | | JEFFB | JEFFB | | HRR | C | 5824399 |
CARRICK GAS PIPING | HI | C | 04/20/2018 | 10# test ok, 1" main, 1- furnace, 1- water heater. | DANR | DANR | | HI | C | 5823165 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/19/2018 | THE WEST BEDROOM IN THE BASEMENT HAS NO SUPPLY RUN. THE FURNACE SPECS ARE GOOD. NOTES: NO DOORS TO THE FINISHED BASEMENT, OUTSIDE AIR TO THE RETURN DUCT AND A/C ROUGH - LINES ONLY. | JEFFB | JEFFB | | HRR | P | 5821639 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | C | 06/01/2018 | note: pvb ok, contractor verified north side vent glued in attic | JOHNS | JOHNS | | P= | C | 5861656 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | R | 05/31/2018 | trip fee waived this time only, no water to unit, re inspect all | JOHNS | JOHNS | | P= | R | 5860103 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | P | 05/30/2018 | trip fee waived, not ready. note: contractor to verify north side vent glued in attic w/ confirmation to inspector in comments section of inspection request | JOHNS | JOHNS | | P= | P | 5858991 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | C | 04/24/2018 | Test ok, aav hall and basement lav, tempering valve by left master lav, finished basement, irrigation stub, expansion devise by final. | DANR | DANR | | PTO | C | 5825942 |
TRADITIONAL PLUMBING AND HEATING LLC | PB | C | 03/26/2018 | Test ok. | DANR | DANR | | PB | C | 5799397 |