TRALON HOMES, LLC | B= | C | 06/12/2018 | Previous items complete | RICHB | RICHB | | B= | C | 5872250 |
TRALON HOMES, LLC | B= | R | 06/07/2018 | 1. Window at master bath not tempered safety glazed / 2. Missing weather strip at garage to dwelling door / 3. Seal penetration at garage common wall // Finished basement / No deck / No AC. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | JUSTINL | JUSTINL | | B= | R | 5868099 |
TRALON HOMES, LLC | BIN | C | 05/08/2018 | Per John Welton Ok | BERTW | BERTW | | BIN | C | 5839157 |
TRALON HOMES, LLC | BFR | C | 05/08/2018 | Item #5 per approved foundation plan note J -3 foundation wall plates are ok/ signed off per John Welton | BERTW | BERTW | | BFR | C | 5839156 |
TRALON HOMES, LLC | BIN | P | 04/30/2018 | Insulation OK pending frame | JUSTINL | JUSTINL | | BIN | P | 5831483 |
TRALON HOMES, LLC | BFR | P | 04/30/2018 | Address item 5 - Other frame correction complete | JUSTINL | JUSTINL | | BFR | P | 5831480 |
TRALON HOMES, LLC | BIN | P | 04/26/2018 | Complete pending frame | JUSTINL | JUSTINL | | BIN | P | 5828443 |
TRALON HOMES, LLC | BFR | P | 04/26/2018 | Frame corrections not made - Next inspection request prior to bearing block correction being complete will result in a trip fee | JUSTINL | JUSTINL | | BFR | P | 5828434 |
TRALON HOMES, LLC | BIN | P | 04/25/2018 | Insulation OK pending frame | JUSTINL | JUSTINL | | BIN | P | 5827497 |
TRALON HOMES, LLC | BFR | P | 04/25/2018 | Address items 1 and 5 / Other frame items complete | JUSTINL | JUSTINL | | BFR | P | 5827494 |
TRALON HOMES, LLC | BFR | P | 04/23/2018 | 1. Bearing block at EE of TR15 in garage not secured with 16D nails / 2. Missing (2) 2x6 at front porch to house LVL / 3. common wall of front room and entry plans call to be framed 24" OC / 4. Missing framing above all windows in basement / 5. 3 plates on foundation - Plan calls for 2 // Temp dry in at frame OK / Plans reviewed electronically ` | JUSTINL | JUSTINL | | BFR | P | 5824720 |
TRALON HOMES, LLC | BSP | P | 04/16/2018 | Front porch post and lid OK | JUSTINL | JUSTINL | | BSP | P | 5818055 |
TRALON HOMES, LLC | BIN | R | 04/12/2018 | Inspection Cancelled by Contractor / | NOAH | NOAH | | BIN | R | 5815509 |
TRALON HOMES, LLC | BSP | P | 04/10/2018 | Narrow braced wall OK | JUSTINL | JUSTINL | | BSP | P | 5813077 |
TRALON HOMES, LLC | BFD | C | 04/02/2018 | | JUSTINL | JUSTINL | | BFD | C | 5804633 |
TRALON HOMES, LLC | BSP | P | 04/02/2018 | Foundation design | JUSTINL | JUSTINL | | BSP | P | 5804632 |
TRALON HOMES, LLC | BFN | C | 04/02/2018 | Engineer letter for foundation -- Eufer noted / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5804631 |
TRALON HOMES, LLC | BFT | C | 04/02/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF ( Verified ) / Drain usable / 10% | JUSTINL | JUSTINL | | BFT | C | 5804630 |
TRALON HOMES, LLC | BFD | P | 03/26/2018 | Drain entire and usable to sump pit / Damp proof OK / Request all foundation paperwork | JUSTINL | JUSTINL | | BFD | P | 5798922 |
TRALON HOMES, LLC | BFT | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFT | P | 5767495 |
TRALON HOMES, LLC | BFN | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFN | P | 5767494 |
J2D ELECTRIC, INC. | E= | C | 06/05/2018 | a/c pre-wire only | TIMA | TIMA | | E= | C | 5864773 |
J2D ELECTRIC, INC. | E= | R | 06/04/2018 | main level smoke detector no power | TIMA | TIMA | | E= | R | 5863221 |
J2D ELECTRIC, INC. | E= | L | 06/01/2018 | house locked at 11:30 | TIMA | TIMA | | E= | L | 5861854 |
J2D ELECTRIC, INC. | ES | C | 04/23/2018 | Residential Underground: 150 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5824008 |
J2D ELECTRIC, INC. | EUG | C | 04/20/2018 | 2/0 urd | TOMC | TOMC | | EUG | C | 5822950 |
J2D ELECTRIC, INC. | ER | C | 04/20/2018 | | TOMC | TOMC | | ER | C | 5822927 |
J2D ELECTRIC, INC. | ER | R | 04/19/2018 | need to install clamp in all boxes with 8-3 ser cable------------- finished basement, ir ufer, no vac, no mcc's | MATTHEW | MATTHEW | | ER | R | 5821805 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 05/30/2018 | | RANDYB | RANDYB | | H= | C | 5859636 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | T | 05/29/2018 | PAID (REC#1503462): Remove the screen from dryer exhaust hood. | RANDYB | RANDYB | | H= | T | 5857754 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 05/25/2018 | Need ladder to verify dryer vent screen. | JACK | JACK | | H= | P | 5855812 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 05/24/2018 | Dryer exhaust appears to be screened. Unless the master bath exhaust and dryer exhaust ducts cross paths in attic before termination? Contractor to verify. NOTES: Finished basement. Outside air to furnace return. High low transfers to mechanical room. No A/C. | RANDYB | RANDYB | | H= | P | 5855155 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/18/2018 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5820003 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/18/2018 | THE FURNACE SPECS ARE ACCURATE. .NOTES: NO DOORS TO THE FINISHED BASEMENT, A/C ROUGH - LINES ONLY AND OUTSIDE AIR TO THE RETURN DUCT. | JEFFB | JEFFB | | HRR | C | 5820001 |
CARRICK GAS PIPING | HI | C | 04/16/2018 | 10# test ok, 1" main, 1- furnace, 1- water heater. | DANR | DANR | | HI | C | 5818103 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | C | 05/31/2018 | corrections made. | JOHNS | JOHNS | | P= | C | 5860094 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | P | 05/30/2018 | trip fee waived, crossed waters @ kit, only luke warm water @ all hall, bsmnt tub, and mstr shwr, no hot water @ mstr tub, need d.w. candy cane, leak @ mstr water closet, recaulk both mstr lavs, bsmnt lav not complete, leak @ water mtr?, rest ok. note: pvb ok | JOHNS | JOHNS | | P= | P | 5858985 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | C | 04/18/2018 | Test ok, correction made. | DANR | DANR | | PTO | C | 5820549 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | P | 04/17/2018 | Low dwv test kitchen, rest ok, 1-vtr, aav hall lav, finished basement (aav lav), tempering valve by right master lav, irrigation stub. | DANR | DANR | | PTO | P | 5819276 |
TRADITIONAL PLUMBING AND HEATING LLC | PB | C | 03/30/2018 | Test ok, | DANR | DANR | | PB | C | 5803927 |