TRALON HOMES, LLC | B= | C | 06/22/2018 | Correction complete | JUSTINL | JUSTINL | | B= | C | 5883300 |
TRALON HOMES, LLC | B= | R | 06/20/2018 | Address item 3 / Other corrections complete / Next inspection request prior to correction being complete will result in a trip fee | JUSTINL | JUSTINL | | B= | R | 5880611 |
TRALON HOMES, LLC | B= | R | 06/19/2018 | 1. Seal all exterior penetrations / 2. Missing weather strip at garage to dwelling door / 3. Missing spindles at all interior guards / 4. Missing sump pump / 5. No ladder set for attic access to inspect insulation // Unfinished basement / No deck / No AC | JUSTINL | JUSTINL | | B= | R | 5878488 |
TRALON HOMES, LLC | BIN | C | 05/04/2018 | | JUSTINL | JUSTINL | | BIN | C | 5836597 |
TRALON HOMES, LLC | BFR | C | 05/04/2018 | Frame correction complete | JUSTINL | JUSTINL | | BFR | C | 5836586 |
TRALON HOMES, LLC | BIN | R | 05/03/2018 | Insulation complete pending frame | JUSTINL | JUSTINL | | BIN | R | 5835111 |
TRALON HOMES, LLC | BFR | P | 05/03/2018 | Address item 4 / Other frame corrections complete | JUSTINL | JUSTINL | | BFR | P | 5835103 |
TRALON HOMES, LLC | BFD | C | 05/03/2018 | | JUSTINL | JUSTINL | | BFD | C | 5834453 |
TRALON HOMES, LLC | BSP | P | 05/03/2018 | Foundation design | JUSTINL | JUSTINL | | BSP | P | 5834450 |
TRALON HOMES, LLC | BFN | C | 05/03/2018 | Engineer letter for foundation -- Eufer noted / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5834449 |
TRALON HOMES, LLC | BFT | C | 05/03/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF ( verified ) / Drain usable / 10% | JUSTINL | JUSTINL | | BFT | C | 5834447 |
TRALON HOMES, LLC | BFR | R | 05/01/2018 | 1. Request all foundation paperwork / 2. Missing roof vents and pipe jacks / 3. Missing TBE6s at TR9 / 4. Clench nails at TR23-25 / 5. Remove framing not floating under basement stairs / 6. Missing point load above steel beam in basement / Plans reviewed electronically | JUSTINL | JUSTINL | | BFR | R | 5832706 |
TRALON HOMES, LLC | BSP | P | 04/18/2018 | Front porch correction complete / Request all foundation paperwork | JUSTINL | JUSTINL | | BSP | P | 5820607 |
TRALON HOMES, LLC | BSP | R | 04/17/2018 | Front porch missing second (3) 2x post - Nails in hangers not clenched / Narrow braced wall OK / No rear porch // Request all foundation paperwork (UPDATE: upon further review - splice allows for single (3) 2x post to be used) JL | JUSTINL | JUSTINL | | BSP | R | 5819393 |
TRALON HOMES, LLC | BFD | P | 03/29/2018 | Drain usable and entire to sump pit / Damp proof OK / Request all foundation paperwork | JUSTINL | JUSTINL | | BFD | P | 5802854 |
TRALON HOMES, LLC | BFT | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFT | P | 5767511 |
TRALON HOMES, LLC | BFN | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFN | P | 5767510 |
J2D ELECTRIC, INC. | E= | C | 06/05/2018 | a/c pre-wire only | TIMA | TIMA | | E= | C | 5864761 |
J2D ELECTRIC, INC. | ES | C | 05/11/2018 | Residential Underground: 150 amp 3.w new res. needs meter seal | TIMA | TIMA | | ES | C | 5842274 |
J2D ELECTRIC, INC. | EUG | C | 05/11/2018 | | TIMA | TIMA | | EUG | C | 5842271 |
J2D ELECTRIC, INC. | ER | C | 04/27/2018 | | TOMC | TOMC | | ER | C | 5829675 |
J2D ELECTRIC, INC. | ER | R | 04/26/2018 | j-box cover missing on can light in kitchen | TIMA | TIMA | | ER | R | 5828718 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/06/2018 | | RANDYB | RANDYB | | H= | C | 5866727 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 06/05/2018 | Single wall vent still lacks 6" clearance to PVC. Seal holes in vent. | RANDYB | RANDYB | | H= | R | 5865103 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 06/04/2018 | WATER HEATER SINGLE WALL VENT CONNECTOR LACKS 6"MIN CLEARANCE TO COMBUSTIBLES. NOTES: UNFINISHED BASEMENT (2 SUPPLY 1 RETURN), OUTSIDE AIR TO FURNACE RETURN, NO A/C | MATTM | MATTM | | H= | P | 5863278 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/30/2018 | RELEASE METER | RANDYB | RANDYB | | HC | C | 5830882 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/30/2018 | BY FINAL: Need a return in unfinished basement. NOTES: Unfinished basement. Outside air to furnace return. A/C Rough line-set only. | RANDYB | RANDYB | | HRR | C | 5830865 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 04/25/2018 | THE MASTER BEDROOM FIREPLACE VENT IS NOT INSTALLED AND THE EAST SIDE OF THE UNIT IS TOO CLOSE TO THE WOOD FRAMING. UNFINISHED BASEMENT NEEDS A RETURN BY FINAL. NOTES: A/C ROUGH - LINES ONLY AND OUTSIDE AIR TO THE RETURN DUCT. | JEFFB | JEFFB | | HRR | R | 5826939 |
BARRETT PLUMBING, INC. | HI | C | 04/19/2018 | 10# test ok, 1" main, 1- furnace, 1- water heater, 1- fireplace. | DANR | DANR | | HI | C | 5822024 |
KIMBEL MECHANICAL SYSTEMS, INC. | P= | C | 06/12/2018 | pvb ok, laundy sink rough only @ this time (vtr) | JOHNS | JOHNS | | P= | C | 5872275 |
KIMBEL MECHANICAL SYSTEMS, INC. | PTO | C | 04/30/2018 | Correction made. | DANR | DANR | | PTO | C | 5831051 |
KIMBEL MECHANICAL SYSTEMS, INC. | PTO | P | 04/27/2018 | Re-grade 2" to master lavs in garage, rest ok, unfinished basement (aav lav), tempering valve by water heater, irrigation stub, | DANR | DANR | | PTO | P | 5829998 |
KIMBEL MECHANICAL SYSTEMS, INC. | PB | C | 04/03/2018 | Test ok. | DANR | DANR | | PB | C | 5806361 |
KIMBEL MECHANICAL SYSTEMS, INC. | PB | P | 04/02/2018 | Low test, rest ok. | DANR | DANR | | PB | P | 5805423 |