CLAYTON PROPERTIES GROUP II, INC. | B= | C | 07/05/2018 | All other required Final inspections are complete. (This is a computer generated result) | SCOTTS | SCOTTS | | B= | C | 5893447 |
CLAYTON PROPERTIES GROUP II, INC. | B= | P | 07/03/2018 | . Additional Inspections Required (computer generated): External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | SCOTTS | SCOTTS | | B= | P | 5893033 |
CLAYTON PROPERTIES GROUP II, INC. | B= | P | 06/28/2018 | complete roof by roof top balcony at exposed sheathing -- crawlspace/no deck -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | SCOTTS | SCOTTS | | B= | P | 5889052 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | C | 06/14/2018 | energy rating on file | SCOTTS | SCOTTS | | BIN | C | 5874038 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | C | 05/17/2018 | | SCOTTS | SCOTTS | | BFR | C | 5848410 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 05/14/2018 | drywall shear ok | SCOTTS | SCOTTS | | BSP | P | 5843590 |
CLAYTON PROPERTIES GROUP II, INC. | BFD | C | 05/08/2018 | engineering observations on file | SCOTTS | SCOTTS | | BFD | C | 5838208 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 05/07/2018 | complete engineering -- not dried in/missing windows -- other corrections complete/no further inspections until engineering received | SCOTTS | SCOTTS | | BFR | R | 5838125 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 05/02/2018 | complete engineering -- not dried in/missing windows/doors -- nail 2nd floor GB1 sill plate down and 3rd floor sill plates per schedule -- need to see drywall shear when installed -- gargae beam calls for trimmers and kings through top plate -- strap top plate at 3" pvc main floor -- brace gable ends 2nd floor | SCOTTS | SCOTTS | | BFR | R | 5833874 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | P | 05/01/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5832978 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | L | 04/25/2018 | field cancelled by Terry w/oakwood | SCOTTS | SCOTTS | | BSP | L | 5826967 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | R | 04/18/2018 | foundation hold downs not per plan -- nail down sill plates per revised schedule/ 2 10d @ 4" or 1 16d @ 6" | SCOTTS | SCOTTS | | BSP | R | 5820551 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | R | 04/12/2018 | porch hold downs on wrong wall -- foundation hold downs not per plan -- nail sill plates per shear schedule | SCOTTS | SCOTTS | | BSP | R | 5815568 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 04/12/2018 | structural set on file | SCOTTS | SCOTTS | | BSP | P | 5814736 |
CLAYTON PROPERTIES GROUP II, INC. | BFD | R | 04/12/2018 | foundation design uploaded -- provide engineering observations | SCOTTS | SCOTTS | | BFD | R | 5814734 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | C | 04/12/2018 | foundation design on file | SCOTTS | SCOTTS | | BFN | C | 5814733 |
CLAYTON PROPERTIES GROUP II, INC. | BFT | C | 04/12/2018 | soils report on file | SCOTTS | SCOTTS | | BFT | C | 5814730 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | L | 04/10/2018 | field cancelled by micheal cone w/oakwood | SCOTTS | SCOTTS | | BSP | L | 5812920 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | L | 04/06/2018 | field cancelled by Micheal Cone w/Oakwood | SCOTTS | SCOTTS | | BSP | L | 5810579 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 03/22/2018 | 1 front pier okay | PAULM | PAULM | | BSP | P | 5796249 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 03/22/2018 | foundation design on file | SCOTTS | SCOTTS | | BSP | P | 5795967 |
CLAYTON PROPERTIES GROUP II, INC. | BFI | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5767710 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5767709 |
J2D ELECTRIC, INC. | E= | C | 06/21/2018 | | RANDY | RANDY | | E= | C | 5881906 |
J2D ELECTRIC, INC. | E= | R | 06/20/2018 | still need ladder | RANDY | RANDY | | E= | R | 5880487 |
J2D ELECTRIC, INC. | E= | R | 06/19/2018 | gfi plug on 3 th floor porch ---------- need ladder to get into crawl space --------- ac ok 25 amp | CRAIG | CRAIG | | E= | R | 5878663 |
J2D ELECTRIC, INC. | ER | C | 05/01/2018 | cables framed for protection / | MIGUEL | MIGUEL | | ER | C | 5832723 |
J2D ELECTRIC, INC. | ER | R | 04/25/2018 | panel relocated and now home run cables need framed in for protection / | MIGUEL | MIGUEL | | ER | R | 5827037 |
J2D ELECTRIC, INC. | ES | C | 04/25/2018 | Residential Underground: 150A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 5827026 |
J2D ELECTRIC, INC. | ES | R | 04/18/2018 | Residential Underground: 150A 3w new res ok to set meter /---------------- service has been moved and needs to be re-inspected | MIGUEL | MIGUEL | | ES | R | 5820716 |
J2D ELECTRIC, INC. | ER | R | 04/18/2018 | IR ufer--crawl space---3-8/3 AL / | MIGUEL | MIGUEL | | ER | R | 5820705 |
STEEL-T HEATING, INC. | H= | C | 06/21/2018 | NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, FULL A/C, NO OUTSIDE AIR, HIGH/LOW GRILLES AT MECHANICAL/LAUNDRY ROOM | BILLS | BILLS | | H= | C | 5882242 |
STEEL-T HEATING, INC. | H= | P | 06/19/2018 | FURNACE VENT TERMINATION INCOMPLETE, UNABLE TO VERIFY CONDITIONED CRAWLSPACE, NEED LADDER TO ACCESS CRAWLSPACE NOTES: HI/LO GRILLS TO MECHANICAL ROOM, NO OUTSIDE AIR, DIRECT VENT FURNACE, A/C INSTALLED | MATTM | MATTM | | H= | P | 5878396 |
BLUE FLAME GAS COMPANY, INC. | HC | C | 04/19/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 5822052 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 04/19/2018 | 10# test ok. note: 1" main at 60' to 1- furnace, 1- water heater and 1- range. | PAULO | PAULO | | HI | C | 5822045 |
STEEL-T HEATING, INC. | HRR | C | 04/18/2018 | Verify conditioned crawlspace at final. NOTE: No outside air per plan, direct vent furnace, A/C rough coil and line set only. | DUSTINS | DUSTINS | | HRR | C | 5820920 |
B & L PLUMBING, INC. | P= | C | 06/12/2018 | 3/4'' pvb installed | TED | TED | | P= | C | 5872079 |
B & L PLUMBING, INC. | PTO | C | 04/16/2018 | aav mech. closet floor drain, sprinkler stub | TED | TED | | PTO | C | 5817905 |
B & L PLUMBING, INC. | PB | C | 03/15/2018 | crawlspace, water under footer | TED | TED | | PB | C | 5789800 |