CLAYTON PROPERTIES GROUP II, INC. | B= | C | 06/26/2018 | All other required Final inspections are complete. (This is a computer generated result) | SCOTTS | SCOTTS | | B= | C | 5885093 |
CLAYTON PROPERTIES GROUP II, INC. | B= | P | 06/25/2018 | corrections complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | SCOTTS | SCOTTS | | B= | P | 5884666 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | C | 06/25/2018 | energy rating on file | SCOTTS | SCOTTS | | BIN | C | 5883798 |
CLAYTON PROPERTIES GROUP II, INC. | B= | P | 06/21/2018 | complete BIN -- complete gutters/downspouts -- extend sump line 36" from house -- upper bath fan not functioning -- crawlspace/no decks -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | SCOTTS | SCOTTS | | B= | P | 5882018 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | C | 05/07/2018 | corrections complete | SCOTTS | SCOTTS | | BFR | C | 5838124 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 05/01/2018 | not dried in/missing windows -- garage beam calls for 4 2x trimmers and 4 2x kings ee -- nail hip bearing blocks | SCOTTS | SCOTTS | | BFR | R | 5832505 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | P | 04/30/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5830674 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | R | 04/25/2018 | sill plate nailing complete -- hold downs not per plan | SCOTTS | SCOTTS | | BSP | R | 5826932 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | R | 04/18/2018 | foundation hold downs not per plan -- nail down sill plates per revised schedule/ 2 10d @ 4" or 1 16d @ 6" | SCOTTS | SCOTTS | | BSP | R | 5820555 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | R | 04/12/2018 | missing posts/blocks at hips -- foundation hold downs not per plan -- nail sill plates per shear schedule | SCOTTS | SCOTTS | | BSP | R | 5815563 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 04/12/2018 | structural set on file | SCOTTS | SCOTTS | | BSP | P | 5814711 |
CLAYTON PROPERTIES GROUP II, INC. | BFD | C | 04/12/2018 | engineering observations on file | SCOTTS | SCOTTS | | BFD | C | 5814709 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | C | 04/12/2018 | foundation design on file | SCOTTS | SCOTTS | | BFN | C | 5814707 |
CLAYTON PROPERTIES GROUP II, INC. | BFT | C | 04/12/2018 | soils report on file | SCOTTS | SCOTTS | | BFT | C | 5814704 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 03/22/2018 | 4 front piers okay. | PAULM | PAULM | | BSP | P | 5796250 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 03/22/2018 | foundation design on file | SCOTTS | SCOTTS | | BSP | P | 5795970 |
CLAYTON PROPERTIES GROUP II, INC. | BFI | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5767717 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | P | 02/16/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5767716 |
J2D ELECTRIC, INC. | E= | C | 06/20/2018 | correction made | RANDY | RANDY | | E= | C | 5880522 |
J2D ELECTRIC, INC. | E= | R | 06/19/2018 | front porch gfi plug is loose --------- ac breaker to big max ac is 20 --------- label panel --------- strap nm cable in crawl space ------------- | CRAIG | CRAIG | | E= | R | 5878658 |
J2D ELECTRIC, INC. | ES | C | 04/23/2018 | Residential Underground: 150A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 5824122 |
J2D ELECTRIC, INC. | ER | C | 04/23/2018 | complete----IR ufer---3-8/3 AL---crawler---no central nac---no mcc / | MIGUEL | MIGUEL | | ER | C | 5824120 |
STEEL-T HEATING, INC. | H= | C | 06/18/2018 | NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, FULL A/C, NO OUTSIDE AIR, 5" COMBUSTION AIR FROM VENTED ATTIC TO MECHANICAL/LAUNDRY ROOM | BILLS | BILLS | | H= | C | 5877724 |
BLUE FLAME GAS COMPANY, INC. | HC | C | 04/23/2018 | RELEASE METER | RANDYB | RANDYB | | HC | C | 5824798 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 04/23/2018 | 10 LB Test okay. | RANDYB | RANDYB | | HI | C | 5824797 |
STEEL-T HEATING, INC. | HRR | C | 04/20/2018 | NOTES: Conditioned crawlspace. Direct vent furnace. 5" High combustion air to mechanical/laundry room. A/C Rough coil and line-set. NO outside air to furnace return. | RANDYB | RANDYB | | HRR | C | 5823496 |
BLUE FLAME GAS COMPANY, INC. | HI | P | 04/19/2018 | low test. note: 1" main at 60' to 1- furnace, 1- water heater and 1- range. | PAULO | PAULO | | HI | P | 5822053 |
B & L PLUMBING, INC. | P= | C | 06/13/2018 | 3/4'' pvb installed | TED | TED | | P= | C | 5873308 |
B & L PLUMBING, INC. | PTO | C | 04/23/2018 | sprinkler stub | TED | TED | | PTO | C | 5824153 |
B & L PLUMBING, INC. | PB | C | 03/15/2018 | crawlspace, water under footer | TED | TED | | PB | C | 5789798 |