WOOD STONE CONSTRUCTION, LLC. | B= | C | 12/06/2018 | Covered rear deck with stairs - Finished basement - AC installed | TIMOTHYS | TIMOTHYS | | B= | C | 6045564 |
WOOD STONE CONSTRUCTION, LLC. | BIN | C | 07/13/2018 | | DALE | DALE | | BIN | C | 5902542 |
WOOD STONE CONSTRUCTION, LLC. | BFR | C | 07/13/2018 | eng. received for garage windows | DALE | DALE | | BFR | C | 5902530 |
WOOD STONE CONSTRUCTION, LLC. | BFR | P | 07/10/2018 | S.W. basement window calls for 2T2K e.e. / Plans need to reflect two windows back of garage | SHAUN | SHAUN | | BFR | P | 5897920 |
WOOD STONE CONSTRUCTION, LLC. | BLA | C | 07/09/2018 | Lath okay | SHAUN | SHAUN | | BLA | C | 5896800 |
WOOD STONE CONSTRUCTION, LLC. | BFR | R | 07/09/2018 | Narrow braced wall covered prior to inspection / Plans don't show windows at back of garage / Missing H2.5 at B2 back of garage / Glue shims in beam pockets / Basement window east side calls for 3- 2x10 header / Missing load bearing blocks in several areas / Basement window calls for 2T2K each end Update: narrow wall okay | SHAUN | SHAUN | | BFR | R | 5896799 |
WOOD STONE CONSTRUCTION, LLC. | BSP | P | 06/15/2018 | porch lid and posts/deck cover and posts/A call out straps/HTS20 on rear for 3 ply girders ok/update/ portal ok | SCOTTS | SCOTTS | | BSP | P | 5876158 |
WOOD STONE CONSTRUCTION, LLC. | BFD | P | 03/22/2018 | need eng. inspection for over excavation drain | DALE | DALE | | BFD | P | 5796907 |
WOOD STONE CONSTRUCTION, LLC. | BFN | C | 03/22/2018 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file / 1500 psf / float 1 1/2" / 10% grade | DALE | DALE | | BFN | C | 5796906 |
WOOD STONE CONSTRUCTION, LLC. | BFT | C | 03/22/2018 | Engineers observation Letter on file / | DALE | DALE | | BFT | C | 5796899 |
WOOD STONE CONSTRUCTION, LLC. | BFD | P | 03/21/2018 | drain is habitable / drain daylighted / damp proofing ok / complete bft bfn | DALE | DALE | | BFD | P | 5795324 |
WOOD STONE CONSTRUCTION, LLC. | BFT | P | 02/21/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5770280 |
WOOD STONE CONSTRUCTION, LLC. | BFN | P | 02/21/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5770279 |
D & J QUALITY ELECTRIC INC | E= | C | 12/06/2018 | Photos accepted | JOSEPH | JOSEPH | | E= | C | 6044276 |
D & J QUALITY ELECTRIC INC | E= | R | 12/05/2018 | Strap cable going to communication box in mech room. --- Cover plate for face up outlet under kitchen sink. --- Shower trim for 2 lights in area under stairs. Will accept photos uploaded to permit. | JOSEPH | JOSEPH | | E= | R | 6043675 |
D & J QUALITY ELECTRIC INC | E= | R | 12/04/2018 | Complete re-inspection required, following is a partial list only. ---- Reverse polarity kitchen outlets. -------- Outlets in Garage miswired, missing GFCI or no power. ----- You need to protect that service riser from physical damage. If you frame it out, it should be at least 18 - 20 inches wide. --- Laundry room missing GFCI protection. --- Install lamps in fixtures ------ No open bulb under stairs. ---- Please hot check before recalling. ---- Notes: Exterior outlets good. --- 30 amp AC | JOSEPH | JOSEPH | | E= | R | 6042503 |
D & J QUALITY ELECTRIC INC | ES | C | 07/06/2018 | Residential Underground: 200 amp 3w new res meter in need reseal | JOSEPH | JOSEPH | | ES | C | 5895161 |
D & J QUALITY ELECTRIC INC | ER | C | 07/06/2018 | Finished basement --------- Floated sub panel. ------ UFER is not ir ----- No vac -------- 2 - 10/3 --- 6/3 al ---- 6/3 cu | JOSEPH | JOSEPH | | ER | C | 5895157 |
D & J QUALITY ELECTRIC INC | EUG | C | 04/25/2018 | | JOSEPH | JOSEPH | | EUG | C | 5827101 |
THE FURNACE GUY HEATING & COOLING | H= | C | 11/01/2018 | corrections made See Image. | TREVORH | TREVORH | | H= | C | 6012556 |
THE FURNACE GUY HEATING & COOLING | H= | P | 10/31/2018 | 14"X6" LOW COMBUSTION AIR GRILLE THAT WAS ADDED NEEDS TO BE RELOCATED, STORAGE ROOM DOES NOT COMMUNICATE WITH THE REST OF HOME(SOLID DOORS). ADDED HIGH GRILLE OK. OK TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. | BILLS | BILLS | | H= | P | 6011937 |
THE FURNACE GUY HEATING & COOLING | H= | P | 10/29/2018 | WATER HEATER BVENT IS MISSING STORM COLLAR, COMPLETE OR CAP KITCHEN EXHAUST, 16"X16" COMBUSTION AIR GRILLES ARE UNDERSIZED FOR MECHANICAL ROOM BTU LOAD (16"X16" ONLY COVERS 192K BTU'S. APPLIANCE LOAD IS 220K BTU'S) NOTE: FINISHED BASEMENT, A/C ROUGH COIL AND LINESET FOR MAIN LEVEL SYSTEM, 2 OUTSIDE AIR'S TO RETURN DUCTS | BILLS | BILLS | | H= | P | 6009046 |
O.M.A.G.M., INC. | HO | C | 09/13/2018 | 10LB TEST OK. 45' OF 1 1/4" POLY PIPE WITH TRACER WIRE FROM EXISTING STUB TO FIRE PIT LOCATION. | BILLS | BILLS | | HO | C | 5964465 |
THE FURNACE GUY HEATING & COOLING | HC | C | 07/02/2018 | RELEASE METER | BILLS | BILLS | | HC | C | 5891874 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 07/02/2018 | BY FINAL: CONFIRM CORRECT SIZE TRANSFER GRILLES AT MECHANICAL ROOM FOR 220K WORTH OF APPLIANCES. NOTE: FINISHED BASEMENT, OUTSIDE AIR X 2, A/C ROUGH COIL AND LINESET ON MAIN LEVEL FURNACE | BILLS | BILLS | | HRR | C | 5891873 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 06/28/2018 | B'VENT LACKS 1 INCH CLEARANCE TO OSB WHERE VENT GOES INTO ATTIC. EITHER VENT WATER HEATERS OR PLUG B-VENT TO GET METER RELEASE. 14 X 14 HIGH/LOW GRILL OPENING TOO SMALL FOR 220,000 BTU'S IN MECHANICAL ROOM. CAN NOT REDUCE SIZE OF GRILLS EVEN IF USING VOLUME OF MECHANICAL ROOM FOR COMBUSTION AIR, SEE IFGC 304.5.3.1 (COMBINING SPACES ON THE SAME STORY). NOTE: FINISHED BASEMENT. OUTSIDE AIR X 2. A/C ROUGH, COIL AND LINESET ON MAIN FURNACE. | NANCY | NANCY | | HRR | P | 5888418 |
J.J. BROOME PLUMBING AND HEATING LLC | HI | C | 06/26/2018 | 10LB TEST OK. 1 1/2" MAIN, 2 FURNACES, 2 WATER HEATERS, 1 COOKTOP, 1 FIREPLACE, 1- 1 1/4" FUTURE FIRE PIT STUB | BILLS | BILLS | | HI | C | 5885831 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | C | 10/25/2018 | note: finished basement, pvb installed | JOSEPHD | JOSEPHD | | P= | C | 6006070 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 06/26/2018 | note: finished basement(2 baths finished), irrigation stub, aav @ wet bar, mixing valve access in toilet room | JOSEPHD | JOSEPHD | | PTO | C | 5885728 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 04/05/2018 | note: water under footer for future out building run into utility room | JOSEPHD | JOSEPHD | | PB | C | 5808901 |