VANGUARD HOMES, INC. | B= | C | 07/24/2018 | Full finished basement -- No deck | DAKOTAB | DAKOTAB | | B= | C | 5912789 |
VANGUARD HOMES, INC. | B= | P | 07/24/2018 | 3rd party insulation cert on file -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DAKOTAB | DAKOTAB | | B= | P | 5911705 |
VANGUARD HOMES, INC. | BFR | C | 05/04/2018 | Items corrected | DAKOTAB | DAKOTAB | | BFR | C | 5836473 |
VANGUARD HOMES, INC. | BLA | C | 05/03/2018 | | DAKOTAB | DAKOTAB | | BLA | C | 5835558 |
VANGUARD HOMES, INC. | BFR | T | 05/03/2018 | PAID (REC#1498121): Items not corrected | DAKOTAB | DAKOTAB | | BFR | T | 5835548 |
VANGUARD HOMES, INC. | BFR | R | 04/30/2018 | missing roof jack at PVC pipe to dry in / rear porch lid covered / narrow braced wall missing straps / tie in left load bearing garage wall at rear corner / combustibles in B-vent chase / roll block missing at rear trusses over slider / tie in 2x6 load bearing wall in front bedroom EE / front door header calls for 7-1/4" LSL / all upper P trusses missing mechanical connection to T trusses | LONNYS | LONNYS | | BFR | R | 5831271 |
VANGUARD HOMES, INC. | BIN | P | 04/27/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5829792 |
VANGUARD HOMES, INC. | BFD | C | 03/07/2018 | Verification of under drain tie in at street on file | DAKOTAB | DAKOTAB | | BFD | C | 5781807 |
VANGUARD HOMES, INC. | BFD | P | 03/06/2018 | Need verification of under drain tie in at street -- Drain is usable to street -- Damp proofing OK | DAKOTAB | DAKOTAB | | BFD | P | 5781440 |
VANGUARD HOMES, INC. | BFN | C | 03/06/2018 | Engineer letter for foundation on file -- Eufer noted -- Foundation design on file (Bearing capacity verified) | DAKOTAB | DAKOTAB | | BFN | C | 5780571 |
VANGUARD HOMES, INC. | BFT | C | 03/06/2018 | Engineer letter for footing on file -- Open hole on file -- 2000 PSF - Drain usable - 10% | DAKOTAB | DAKOTAB | | BFT | C | 5780569 |
VANGUARD HOMES, INC. | BFT | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 5779513 |
VANGUARD HOMES, INC. | BFN | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 5779512 |
POSITIVE ELECTRIC, LLC | E= | C | 07/06/2018 | correction made | RANDY | RANDY | | E= | C | 5894823 |
POSITIVE ELECTRIC, LLC | E= | R | 06/22/2018 | wet bar has no power-----25 amp a/c | RANDY | RANDY | | E= | R | 5883054 |
POSITIVE ELECTRIC, LLC | ES | C | 04/27/2018 | Residential Underground: 150 amp 3/w new res | RANDY | RANDY | | ES | C | 5829756 |
POSITIVE ELECTRIC, LLC | ER | C | 04/27/2018 | 3-#8al, 1-10, 1-12, irreversible ufer, finished basement, no vac, a/c stub | RANDY | RANDY | | ER | C | 5829738 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/23/2018 | | JEFFL | JEFFL | | H= | C | 5910700 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 07/20/2018 | Vent terminations still not complete. Coil change letter still needed. | JEFFL | JEFFL | | H= | R | 5909525 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 06/28/2018 | NEED PROPER FURNACE VENT TERMINATION, SEE PAGE 34 AND 35 IN THE INSTALLATION INSTRUCTIONS. COMPLETE KITCHEN EXHAUST. NEED CHANGE OF EQUIPMENT LETTER FOR FURNACE AND COIL. NOTE: OUTSIDE AIR TO FURNACE RETURN, A/C INSTALLED, DIRECT VENT FURNACE, FINISHED BASEMENT, HIGH/LOW GRILLES TO MECHANICAL ROOM. | DUSTINS | DUSTINS | | H= | P | 5889022 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/24/2018 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5825567 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/24/2018 | | JEFFL | JEFFL | | HRR | C | 5825556 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/23/2018 | Insulation shield needed around fireplace vent in attic. Dryer vent exceeds 35'. Equipment change letter needed at final. Notes-- AC rough. Finished basement. Direct vent furnace. Outside air to return. | JEFFL | JEFFL | | HRR | P | 5824371 |
SPRINGS GAS, INC. | HI | C | 04/23/2018 | 10 lb test ok. 1 1/4'' MAIN.. 1 FURNACE.. 1 WATER HEATER.. 1 FIREPLACE.. 1 RANGE.. 1 BBQ.. | JEFFL | JEFFL | | HI | C | 5824356 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | C | 06/26/2018 | corrections made | JOSEPHD | JOSEPHD | | P= | C | 5885389 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | P | 06/25/2018 | Loose shower arm basement bath, trap guard laundry, rest ok. Finish basement, pvb installed. | DANR | DANR | | P= | P | 5884644 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | C | 04/24/2018 | corrections made | JOSEPHD | JOSEPHD | | PTO | C | 5825673 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | P | 04/23/2018 | low test at water pipe, low test at floor drain dwv, need nail protection at washer box dwv, rest ok note: finished basement, irrigation stub, aav @ hall lav, both master lavs, basement lav, wet bar | JOSEPHD | JOSEPHD | | PTO | P | 5823864 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | L | 04/20/2018 | all doors locked @ 2:44 p.m. | JOHNS | JOHNS | | PTO | L | 5823258 |
TRADITIONAL PLUMBING AND HEATING LLC | PB | C | 03/12/2018 | | CALE | CALE | | PB | C | 5786006 |