JACKSON HOMES LLC | B= | C | 11/21/2018 | | BOBF | BOBF | | B= | C | 6032786 |
JACKSON HOMES LLC | B= | P | 11/19/2018 | provide ladder and open scuttle for attic access / water in sump pit, install sump pump -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 6030217 |
JACKSON HOMES LLC | BLA | C | 06/27/2018 | | BOBF | BOBF | | BLA | C | 5887764 |
JACKSON HOMES LLC | BIN | P | 06/20/2018 | Garage door temp dried in -- Insulation OK -- Other item corrected | DAKOTAB | DAKOTAB | | BIN | P | 5880720 |
JACKSON HOMES LLC | BIN | R | 06/19/2018 | Still missing garage doors to complete dry in - Need to seal gaps at upstairs fireplace fire block - everything else ok | TIMOTHYS | TIMOTHYS | | BIN | R | 5878392 |
JACKSON HOMES LLC | BFR | R | 06/14/2018 | still missing garage doors, rest of house okay | BOBF | BOBF | | BFR | R | 5875247 |
JACKSON HOMES LLC | BFR | P | 06/14/2018 | eng letter for front steel beam post,, portal wall framing,, front porch framing and all porch posts on file | BOBF | BOBF | | BFR | P | 5874113 |
JACKSON HOMES LLC | BFR | T | 06/08/2018 | PAID (REC#1507297) Side wall of portal walls are greater than 6 to 1 ratio per detail / missing garage doors / 2 Hts 20 at rear porch beams let in to house, St 18 at 3- 2x4 posts to header at great room window / plans call for 3 - 9 1/2" LVL header at window above stair landing / LTSTA straps to be installed over top of rafter peaks on front portch/ plans call for BC64 post caps at all porch posts / front porch ridge beam not supported per plan / truss lateral laps to intersect 2 trusses at all locations multiple trusses are tied together / plans call for steel beam to be seated in concrete beam pocket at garage common wall / missing point loads at back of house, all point loads to be carried down to foundation / 5 kings at left side of slider in basement / missing 3" sch 40 at right side of slide in basement | BOBF | BOBF | | BFR | T | 5869579 |
JACKSON HOMES LLC | BFR | T | 06/05/2018 | PAID (REC#1505955) still too many items to list, please call me in am to discuss 327- 2923 | BOBF | BOBF | | BFR | T | 5865479 |
JACKSON HOMES LLC | BFR | R | 05/31/2018 | inspection stopped, house not ready / missing hardware, missing posts , missing all bearing blocks, portal wall not nailed per plan and width at end wall is less than minimum width | BOBF | BOBF | | BFR | R | 5861230 |
JACKSON HOMES LLC | BSP | P | 04/20/2018 | 2 rear 30" piers OK / still need to inspect landing piers | LONNYS | LONNYS | | BSP | P | 5823480 |
JACKSON HOMES LLC | BFT | C | 04/20/2018 | received foundation design (bearing capacity verified) | LONNYS | LONNYS | | BFT | C | 5823473 |
JACKSON HOMES LLC | BFI | C | 02/26/2018 | | BOBF | BOBF | | BFI | C | 5773465 |
JACKSON HOMES LLC | BFD | C | 02/26/2018 | | BOBF | BOBF | | BFD | C | 5773463 |
JACKSON HOMES LLC | BFN | C | 02/26/2018 | | BOBF | BOBF | | BFN | C | 5773462 |
JACKSON HOMES LLC | BFT | P | 02/26/2018 | still need foundation design | BOBF | BOBF | | BFT | P | 5773460 |
JACKSON HOMES LLC | BFI | R | 02/22/2018 | see footing comments / R-10 Rigid installed | BOBF | BOBF | | BFI | R | 5772000 |
JACKSON HOMES LLC | BFD | R | 02/22/2018 | see footing comments , drain installed is exterior and usable | BOBF | BOBF | | BFD | R | 5771999 |
JACKSON HOMES LLC | BFN | R | 02/22/2018 | see footing comments / letter for steel and eufer on file | BOBF | BOBF | | BFN | R | 5771998 |
JACKSON HOMES LLC | BFT | R | 02/22/2018 | footing poured prior to permit, footing letter for footing shows Feb 5, 2018, permit was pulled Feb 21, open hole 2000# and letter for footing on file / still need foundation design | BOBF | BOBF | | BFT | R | 5771997 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 10/04/2018 | 30 amp a/c | TOMC | TOMC | | E= | C | 5985750 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 05/29/2018 | Residential Underground: 200 - amp 3 Wire new service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5857976 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 05/29/2018 | install plug in unfinished storage area ( left of stairs) check on final | CRAIG | CRAIG | | ER | C | 5857974 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | R | 05/25/2018 | Residential Underground: 200 amp service new res | BRET | BRET | | ES | R | 5856896 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | R | 05/25/2018 | install ground bushing on metal flex or metal box for master floor heat (plastic box with metal flex), add receptacle to unfinished storage area (left of stairs) sheathing damaged on se cable above sub panel and right of main panel. #6 al oven and cook top. #2 sub, no mcc, no vac, ir ufer | BRET | BRET | | ER | R | 5856895 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 10/25/2018 | CORRECTIONS MADE, SEE IMAGES | BENH | BENH | | H= | C | 6005288 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 10/19/2018 | DRYER VENT CAP STILL HAS BIRDSCREEN NOTES: FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C COMPLETE | BENH | BENH | | H= | P | 6000043 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 10/02/2018 | DRYER VENT HAS BIRD SCREEN IN ROOF CAP, EXHAUST VENT NEXT TO CONDENSER HAS STUCCO OVER FLAPPER PREVENTING IT TO OPEN, GAS METER ISN'T INSTALLED YET NOTES: FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C COMPLETE | BENH | BENH | | H= | P | 5983190 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 05/25/2018 | RELEASE METER FOR 2 LB SYSTEM | BENH | BENH | | HC | C | 5856221 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 05/25/2018 | NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C ROUGH COIL AND LINE SET | BENH | BENH | | HRR | C | 5856219 |
DAVIS GAS SHOP INC | HI | C | 05/24/2018 | BY FINAL NEED LETTER OF APPROVAL FOR 2 LB SYSTEM, AND CHECK FOR REGULATOR IN PLACE IN MECHANICAL ROOM, MEDIUM PRESSURE LABELING ALREADY COMPLETE 10 LB TEST OK, #25 CSST MAIN( MEDIUM PRESSURE), 1 FURNACE , 1 WATER HEATER, 2 FIREPLACE, 1 COOKTOP, 1 FUTURE BBQ STUB | BENH | BENH | | HI | C | 5854876 |
JOLLY PLUMBING & HEATING INC. | P= | C | 10/12/2018 | Corrections made | MALYNDA | MALYNDA | | P= | C | 5992991 |
JOLLY PLUMBING & HEATING INC. | P= | P | 10/10/2018 | Need caulking at all shower/bathtub valves and faucets, secure toilet in basement powder bath, rest ok. Note: pvb installed. | MALYNDA | MALYNDA | | P= | P | 5990837 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 05/22/2018 | note: finished basement(2 baths finished), irrigation stub, mixing LH master lav, aav @ powder room lav, hall bath lav, both master lavs, basement powder lav, both basement lavs | JOSEPHD | JOSEPHD | | PTO | C | 5852287 |
JOLLY PLUMBING & HEATING INC. | PB | C | 03/23/2018 | | JOSEPHD | JOSEPHD | | PB | C | 5797642 |