CAMPBELL HOMES LTD. | B= | C | 07/19/2018 | Full finished basement -- Rear deck | DAKOTAB | DAKOTAB | | B= | C | 5907839 |
CAMPBELL HOMES LTD. | BSP | P | 07/19/2018 | Engineer letter for deck landing received -- Landing frame OK | DAKOTAB | DAKOTAB | | BSP | P | 5907830 |
CAMPBELL HOMES LTD. | BSP | P | 07/16/2018 | Need stamped detail for deck landing -- 4 piers currently dug at 10"x30" | DAKOTAB | DAKOTAB | | BSP | P | 5903917 |
CAMPBELL HOMES LTD. | BSP | P | 06/29/2018 | 3 deck piers OK | DAKOTAB | DAKOTAB | | BSP | P | 5890079 |
CAMPBELL HOMES LTD. | BLA | C | 06/06/2018 | Lath OK. | PARKER | PARKER | | BLA | C | 5866176 |
CAMPBELL HOMES LTD. | BIN | C | 05/01/2018 | | LONNYS | LONNYS | | BIN | C | 5831765 |
CAMPBELL HOMES LTD. | BFR | C | 05/01/2018 | picture of top plate to header in third car garage on file | LONNYS | LONNYS | | BFR | C | 5831764 |
CAMPBELL HOMES LTD. | BIN | P | 04/27/2018 | Complete BFR -- Insulation OK | DAKOTAB | DAKOTAB | | BIN | P | 5829742 |
CAMPBELL HOMES LTD. | BFR | P | 04/27/2018 | Still need to strap top plate to header at side of 3rd garage -- Other item corrected -- Engineer letter for steel channel at window received -- Front porch item corrected -- Deck frame OK | DAKOTAB | DAKOTAB | | BFR | P | 5829732 |
CAMPBELL HOMES LTD. | BFR | P | 04/25/2018 | OK to insulate -- Strap top plate to header at side of 3rd car garage -- Need to block panel splices at rear shear wall in 3rd car garage -- Window cut into foundation at front basement bedroom with C- channel steel run around not shown on plans | DAKOTAB | DAKOTAB | | BFR | P | 5827240 |
CAMPBELL HOMES LTD. | BFT | C | 04/25/2018 | Engineer letter for footing on file -- Open hole on file -- 2000 PSF - Drain usable - 10% | DAKOTAB | DAKOTAB | | BFT | C | 5826211 |
CAMPBELL HOMES LTD. | BSP | P | 04/13/2018 | Narrow braced wall OK | DAKOTAB | DAKOTAB | | BSP | P | 5816628 |
CAMPBELL HOMES LTD. | BSP | P | 04/13/2018 | Need to strap top plate to (2) 2x10 header on front porch -- Front porch porch OK -- Rear porch post and lid OK | DAKOTAB | DAKOTAB | | BSP | P | 5816623 |
CAMPBELL HOMES LTD. | BFI | C | 03/13/2018 | 2" foam insulation OK | DAKOTAB | DAKOTAB | | BFI | C | 5787670 |
CAMPBELL HOMES LTD. | BFI | R | 03/13/2018 | No insulation installed | DAKOTAB | DAKOTAB | | BFI | R | 5787539 |
CAMPBELL HOMES LTD. | BFD | C | 03/13/2018 | Drain is usable to street -- Damp proofing OK | DAKOTAB | DAKOTAB | | BFD | C | 5787529 |
CAMPBELL HOMES LTD. | BFN | C | 03/13/2018 | Engineer letter for foundation on file -- Eufer noted | DAKOTAB | DAKOTAB | | BFN | C | 5786848 |
CAMPBELL HOMES LTD. | BFT | C | 03/13/2018 | Engineer letter for footing on file | DAKOTAB | DAKOTAB | | BFT | C | 5786845 |
CAMPBELL HOMES LTD. | BFD | P | 03/13/2018 | Open hole on file -- 2000 PSF - Drain usable - 10% -- Foundation design on file (Bearing capacity verified) | DAKOTAB | DAKOTAB | | BFD | P | 5786809 |
CAMPBELL HOMES LTD. | BFT | P | 02/22/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5771115 |
CAMPBELL HOMES LTD. | BFN | P | 02/22/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5771114 |
POSITIVE ELECTRIC, LLC | E= | C | 07/18/2018 | correction made | RANDY | RANDY | | E= | C | 5906225 |
POSITIVE ELECTRIC, LLC | E= | R | 07/17/2018 | max for a/c is 25 amps breaker is a 30 | RANDY | RANDY | | E= | R | 5904723 |
POSITIVE ELECTRIC, LLC | ES | C | 04/24/2018 | Residential Underground: 150 amp 3/w new res | RANDY | RANDY | | ES | C | 5825239 |
POSITIVE ELECTRIC, LLC | ER | C | 04/24/2018 | corrections made | RANDY | RANDY | | ER | C | 5825233 |
POSITIVE ELECTRIC, LLC | ES | R | 04/23/2018 | Residential Underground: can' t verify wire size --------- leave piece of wire behind | CRAIG | CRAIG | | ES | R | 5823749 |
POSITIVE ELECTRIC, LLC | ER | R | 04/23/2018 | add plugs to the left of slide door and left of bottom stair ------------ no mcc 10/3 3 - 8/3 al No Cent Vac / Non Irreversible UFER connection / Finished Basement / | CRAIG | CRAIG | | ER | R | 5823741 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/09/2018 | Notes-- AC complete. Finished basement. Outside air to return. | JEFFL | JEFFL | | H= | C | 5896284 |
SPRINGS GAS, INC. | HC | C | 04/20/2018 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5822478 |
SPRINGS GAS, INC. | HI | C | 04/20/2018 | 10 lb test ok. 1 1/4'' main.. 1 furnace.. 1 water heater.. 1 fireplace.. 1 range.. 1 bbq.. 1 dryer.. | JEFFL | JEFFL | | HI | C | 5822460 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/20/2018 | | JEFFL | JEFFL | | HRR | C | 5822435 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/19/2018 | LOW VOLTAGE WIRE TOUCHING B-VENT ON MAIN LEVEL, ADDITIONAL SUPPORT FOR FURNACE VENT NOTES: FINISH BASEMENT, A/C COIL AND LINE SET ROUGH, OUTSIDE AIR TO RETURN, | JEFFL | JEFFL | | HRR | P | 5821448 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | L | 04/18/2018 | Field cancelled. | JEFFL | JEFFL | | HRR | L | 5820009 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 06/25/2018 | Ok, finish basement, pvb installed. | DANR | DANR | | P= | C | 5884537 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 04/18/2018 | corrections made | JOHNS | JOHNS | | PTO | C | 5820689 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | P | 04/17/2018 | low water test, nail protection for pex lines to wet bar, rest ok note: finished basement, irrigation stub, mixing valve above manifold aav @ wet bar, basement bath lav | JOSEPHD | JOSEPHD | | PTO | P | 5819288 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 03/21/2018 | | CALE | CALE | | PB | C | 5795413 |