STEPHENS AND ASSOCIATES, INC. | B= | C | 11/19/2018 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 6030054 |
STEPHENS AND ASSOCIATES, INC. | B= | P | 11/15/2018 | Final inspection correction complete. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | JUSTINL | JUSTINL | | B= | P | 6026832 |
STEPHENS AND ASSOCIATES, INC. | B= | R | 10/23/2018 | Missing spindles in guard at basement stairs // Finished basement / No deck / No AC. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819). | JUSTINL | JUSTINL | | B= | R | 6003484 |
STEPHENS AND ASSOCIATES, INC. | BLA | C | 09/04/2018 | Lath OK | JUSTINL | JUSTINL | | BLA | C | 5954204 |
STEPHENS AND ASSOCIATES, INC. | BIN | C | 08/24/2018 | | JUSTINL | JUSTINL | | BIN | C | 5945153 |
STEPHENS AND ASSOCIATES, INC. | BFR | C | 08/24/2018 | Frame complete - No joist repair needed per engineer letter | JUSTINL | JUSTINL | | BFR | C | 5945152 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 08/24/2018 | Engineer letter for hole in joist on file | JUSTINL | JUSTINL | | BSP | P | 5944621 |
STEPHENS AND ASSOCIATES, INC. | BFR | R | 08/23/2018 | Field canceled by contractor | JUSTINL | JUSTINL | | BFR | R | 5943936 |
STEPHENS AND ASSOCIATES, INC. | BIN | R | 08/22/2018 | Insulation OK pending frame | JUSTINL | JUSTINL | | BIN | R | 5942258 |
STEPHENS AND ASSOCIATES, INC. | BFR | P | 08/22/2018 | address items 3-5 of frame inspection / Other frame correction complete / Temp dry in complete (UPDATE: met with contractor and framer on site to review frame items - address item 5 - Other frame items corrected - Stamped plans reviewed on site for fire place location - Changed to partial ) JL | JUSTINL | JUSTINL | | BFR | P | 5942257 |
STEPHENS AND ASSOCIATES, INC. | BFN | C | 08/22/2018 | Engineer letter for foundation -- Eufer noted / | JUSTINL | JUSTINL | | BFN | C | 5941762 |
STEPHENS AND ASSOCIATES, INC. | BFT | C | 08/22/2018 | Engineers observation Letter on file / | JUSTINL | JUSTINL | | BFT | C | 5941760 |
STEPHENS AND ASSOCIATES, INC. | BIN | R | 08/20/2018 | Field canceled by contractor - Request footer and foundation observations prior to any further field inspections | JUSTINL | JUSTINL | | BIN | R | 5939363 |
STEPHENS AND ASSOCIATES, INC. | BFR | R | 08/20/2018 | Field canceled by contractor - Request footer and foundation observations prior to any further field inspections | JUSTINL | JUSTINL | | BFR | R | 5939355 |
STEPHENS AND ASSOCIATES, INC. | BIN | T | 08/17/2018 | PAID (REC#1528378): Insulation installed prior to dry in being complete - Missing doors - Recall for full insulation inspection after dry in complete | JUSTINL | JUSTINL | | BIN | T | 5938010 |
STEPHENS AND ASSOCIATES, INC. | BFR | R | 08/17/2018 | Frame corrections not complete - Next inspection request prior to corrections being complete will result in a trip fee - Request footer and foundation observation to complete BFT and BFN | JUSTINL | JUSTINL | | BFR | R | 5938007 |
STEPHENS AND ASSOCIATES, INC. | BFN | P | 08/17/2018 | Foundation design on file / Request foundation observation | JUSTINL | JUSTINL | | BFN | P | 5937212 |
STEPHENS AND ASSOCIATES, INC. | BFT | P | 08/17/2018 | Open hole on file - 2000 PSF ( verified ) / Drain usable and over ex / 10% / Request footer observation | JUSTINL | JUSTINL | | BFT | P | 5937211 |
STEPHENS AND ASSOCIATES, INC. | BFD | C | 08/17/2018 | Over ex and usable drain observation on file | JUSTINL | JUSTINL | | BFD | C | 5937208 |
STEPHENS AND ASSOCIATES, INC. | BFR | R | 08/10/2018 | 1. Request foundation and drain paperwork prior to any further field inspections / 2.Missing window and doors to complete dry in / 3. Missing ST22 straps per note (A) at all locations / 4. Fireplace in different location than called out on plans - Fireblock fireplace chase at 10' / 5. 7" hole drilled in floor joist 16" from bearing point below guest bath / Plans reviewed electronically / | JUSTINL | JUSTINL | | BFR | R | 5930846 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 07/17/2018 | Front porch 2ply LVL not bearing on posts at EE / Narrow braced wall OK / Request foundation paperwork // UPDATE: upon further review - 2ply lvl is not structural - Gable is supported at EE by 2ply LVLs that are bearing on posts - Front porch posts and lid OK | JUSTINL | JUSTINL | | BSP | P | 5904865 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 07/17/2018 | Drain tie in photo
| JUSTINL | JUSTINL | | BSP | P | 5904531 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 07/17/2018 | Drain tie in photo | JUSTINL | JUSTINL | | BSP | P | 5904530 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 07/17/2018 | Foundation deign | JUSTINL | JUSTINL | | BSP | P | 5904529 |
STEPHENS AND ASSOCIATES, INC. | BFD | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFD | P | 5772260 |
STEPHENS AND ASSOCIATES, INC. | BFT | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5772259 |
STEPHENS AND ASSOCIATES, INC. | BFN | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5772258 |
J2D ELECTRIC, INC. | E= | C | 10/03/2018 | no a/c | TIMA | TIMA | | E= | C | 5984726 |
J2D ELECTRIC, INC. | E= | R | 10/02/2018 | need to expose service lateral at house to verify depth was corrected as requested on service inspection---rest ok-- | TIMA | TIMA | | E= | R | 5983047 |
J2D ELECTRIC, INC. | ES | C | 10/02/2018 | Residential Underground: 150 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5983044 |
J2D ELECTRIC, INC. | ER | C | 08/09/2018 | #8 AL to oven/range / No Cent Vac / Irreversible UFER connection / Finished Basement / | TIMA | TIMA | | ER | C | 5929748 |
J2D ELECTRIC, INC. | ER | T | 08/08/2018 | PAID (REC#1525335): corrections not made | TIMA | TIMA | | ER | T | 5927796 |
J2D ELECTRIC, INC. | ER | R | 08/07/2018 | corrections not made | TIMA | TIMA | | ER | R | 5926541 |
J2D ELECTRIC, INC. | ES | R | 08/06/2018 | service lateral not 24" at house | TIMA | TIMA | | ES | R | 5924789 |
J2D ELECTRIC, INC. | ER | R | 08/06/2018 | open j-box master can light,need hall recept in basement,wire hanging in basement bath at tub | TIMA | TIMA | | ER | R | 5924779 |
J2D ELECTRIC, INC. | EUG | C | 05/11/2018 | 2/0 | TIMA | TIMA | | EUG | C | 5842701 |
AMERINE HEATING & COOLING LLC | H= | C | 10/18/2018 | | MATTM | MATTM | | H= | C | 5998430 |
AMERINE HEATING & COOLING LLC | H= | R | 10/17/2018 | COMMON VENT LACKS 1" CLEARANCE TO WOOD IN MECHANICAL ROOM, INSTALL FURNACE FILTER, TRIP FEE WAIVED | MATTM | MATTM | | H= | R | 5997863 |
AMERINE HEATING & COOLING LLC | H= | R | 10/16/2018 | HIGH TRANSFER TO MECHANICAL ROOM IS STILL TOO LOW, TOP OF TRANSFER NEEDS TO BE LOCATED 12" MAXIMUM FROM CEILING OR AS CLOSE AS POSSIBLE, INSTALL FURNACE FILTER, COMMON VENT LACKS 1" CLEARANCE TO WOOD IN MECHANICAL ROOM | MATTM | MATTM | | H= | R | 5996160 |
AMERINE HEATING & COOLING LLC | H= | P | 09/26/2018 | INSTALL MISSING SUPPLY IN MECHANICAL ROOM, DRYER TERMINATION CANNOT HAVE A SCREEN, THERMOSTAT NOT INSTALLED, TOP HI/LO GRILL NEEDS TO COMMENCE WITHIN THE TOP 12" OF CEILING OR AS CLOSE AS POSSIBLE BECAUSE I-BEAM WOULD BLOCK 6" CLEARANCE, VINYL IS TOUCHING B-VENT IN MECHANICAL ROOM, FURNACE VENT CONNECTOR LACKS GRADE, INSTALL FURNACE FILTER NOTES: FINISHED BASEMENT, HI/LO GRILLS TO MECHANICAL ROOM, OUTSIDE AIR TO FURNACE RETURN, NO A/C | MATTM | MATTM | | H= | P | 5977512 |
AMERINE HEATING & COOLING LLC | H= | P | 09/26/2018 | RECEIVED EQUIPMENT CHANGE LETTER FROM CONTRACTOR, SEE IMAGES | MATTM | MATTM | | H= | P | 5976691 |
AMERINE HEATING & COOLING LLC | HC | C | 08/08/2018 | RELEASE METER | MATTM | MATTM | | HC | C | 5927743 |
AMERINE HEATING & COOLING LLC | HRR | C | 08/08/2018 | | MATTM | MATTM | | HRR | C | 5927741 |
AMERINE HEATING & COOLING LLC | HRR | P | 08/06/2018 | FIREPLACE VENT LACKS REQUIRED CLEARANCE TO COMBUSTIBLES. | MATTM | MATTM | | HRR | P | 5925105 |
AMERINE HEATING & COOLING LLC | HRR | P | 08/03/2018 | SEAL ELECTRICAL RETURN PENETRATIONS IN BASEMENT BEDROOMS #3 & 4, FIREPLACE VENT LACKS CLEARANCE TO COMBUSTIBLES, BY FINAL: FURNACE EQUIPMENT CHANGE LETTER, INSTALL 6" SUPPLY IN MECHANICAL ROOM, FURNACE VENT NEEDS PROPER GRADE NOTES: FINISHED BASEMENT, OUTSIDE AIR TO FURNACE RETURN, NO A/C | MATTM | MATTM | | HRR | P | 5923636 |
SPRINGS GAS, INC. | HI | C | 07/26/2018 | 10LB TEST OK 1" MAIN 1 FURNACE, 1 WATER HEATER, 1 FIREPLACE | MATTM | MATTM | | HI | C | 5914853 |
MD SERVICE PLUMBING, INC. | P= | C | 10/03/2018 | pvb ok, finished bsmnt | JOHNS | JOHNS | | P= | C | 5984670 |
MD SERVICE PLUMBING, INC. | PTO | C | 07/27/2018 | vtr (3), tempering @ left mstr, finished bsmnt, aav @ bsmnt lav, irrigation stub | JOHNS | JOHNS | | PTO | C | 5916772 |
MD SERVICE PLUMBING, INC. | PB | C | 05/07/2018 | | JOHNS | JOHNS | | PB | C | 5837604 |