STEPHENS AND ASSOCIATES, INC. | B= | C | 09/06/2018 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 5957039 |
STEPHENS AND ASSOCIATES, INC. | B= | P | 09/06/2018 | Finished basement / No deck / No AC. Additional Inspections Required (computer generated): External Agency Inspection UWS by WIDEFIELDWSD is not Completed yet (Contact: Wateropps@wwsdonline.com or 390-7111). | JUSTINL | JUSTINL | | B= | P | 5956999 |
STEPHENS AND ASSOCIATES, INC. | B= | R | 09/04/2018 | Field canceled by contractor on site. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819), External Agency Inspection UWS by WIDEFIELDWSD is not Completed yet (Contact: Wateropps@wwsdonline.com or 390-7111). | JUSTINL | JUSTINL | | B= | R | 5954200 |
STEPHENS AND ASSOCIATES, INC. | BLA | C | 07/19/2018 | Lath OK | JUSTINL | JUSTINL | | BLA | C | 5907897 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 07/17/2018 | Drain tie in photo on file | JUSTINL | JUSTINL | | BSP | P | 5904539 |
STEPHENS AND ASSOCIATES, INC. | BIN | C | 06/27/2018 | Insulation OK | JUSTINL | JUSTINL | | BIN | C | 5887379 |
STEPHENS AND ASSOCIATES, INC. | BFR | C | 06/27/2018 | Frame corrections complete | JUSTINL | JUSTINL | | BFR | C | 5887363 |
STEPHENS AND ASSOCIATES, INC. | BFR | R | 06/25/2018 | Address item 1 ( Missing 2 roof pipe jacks ) and 6-8 - Next inspection request prior to all frame corrections being complete will result in a trip fee | JUSTINL | JUSTINL | | BFR | R | 5884459 |
STEPHENS AND ASSOCIATES, INC. | BSP | R | 06/21/2018 | Foundation design already on file | JUSTINL | JUSTINL | | BSP | R | 5881050 |
STEPHENS AND ASSOCIATES, INC. | BFR | R | 06/20/2018 | 1. Missing roof pipe jacks to complete dry in / 2. Missing H2.5s at A09 entry wall at front bed / 3. Missing ST12 at front bed window / 4. Missing ST22 straps at all note (A) locations / 5. Missing studs under window in master / 6. Tie balloon walls at great room together at ridge and to lower walls / 7. Exposed rebar in beam pockets / 8. Missing solid blocking at rear cantilever in basement / Plans reviewed electronically / | JUSTINL | JUSTINL | | BFR | R | 5880472 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 06/12/2018 | Front and rear porch bearing correction made | JUSTINL | JUSTINL | | BSP | P | 5872035 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 06/04/2018 | Narrow wall - Nailing at panel splice and blocking OK. Front and rear porch posts on north side still have less than 3" of bearing at base. | PARKER | PARKER | | BSP | P | 5863323 |
STEPHENS AND ASSOCIATES, INC. | BSP | R | 05/29/2018 | Narrow braced wall - Finish nailing panel splice to common blocking - rest OK / Front porch post at N side less than 3" of bearing at base - Other post OK - Front porch lid OK / Rear porch post at N side less than 3" of bearing at base - Other post OK | JUSTINL | JUSTINL | | BSP | R | 5857600 |
STEPHENS AND ASSOCIATES, INC. | BFD | C | 05/18/2018 | Drain observation with tie in | SHAUN | SHAUN | | BFD | C | 5848973 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 05/18/2018 | Open hole report / 2,000 psf / Drain around habitable space / Interior isolate and 1 1/2" float / 10% grade / Drain design | SHAUN | SHAUN | | BSP | P | 5848972 |
STEPHENS AND ASSOCIATES, INC. | BFN | C | 05/18/2018 | Foundation observation with eufer noted | SHAUN | SHAUN | | BFN | C | 5848971 |
STEPHENS AND ASSOCIATES, INC. | BFT | C | 05/18/2018 | Footing observation o file | SHAUN | SHAUN | | BFT | C | 5848969 |
STEPHENS AND ASSOCIATES, INC. | BFT | R | 05/16/2018 | Engineer observation for footers part of engineer stamp not visible - Request engineer observation with visible engineer stamp, soils and open hole, Foundation design | JUSTINL | JUSTINL | | BFT | R | 5846172 |
STEPHENS AND ASSOCIATES, INC. | BFD | P | 05/16/2018 | Engineer observation for usable and over ex drain on file / Request foundation paperwork | JUSTINL | JUSTINL | | BFD | P | 5846171 |
STEPHENS AND ASSOCIATES, INC. | BFT | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5772267 |
STEPHENS AND ASSOCIATES, INC. | BFD | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFD | P | 5772268 |
STEPHENS AND ASSOCIATES, INC. | BFN | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5772266 |
J2D ELECTRIC, INC. | E= | C | 08/09/2018 | a/c pre-wire only | TIMA | TIMA | | E= | C | 5929738 |
J2D ELECTRIC, INC. | ER | C | 06/13/2018 | #8 AL to oven/range / No Cent Vac / Irreversible UFER connection / Finished Basement / | TIMA | TIMA | | ER | C | 5873265 |
J2D ELECTRIC, INC. | ES | C | 06/13/2018 | Residential Underground: 200 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5873254 |
J2D ELECTRIC, INC. | EUG | C | 05/15/2018 | INSTALL THE CAUTION TAPE----4/0 AL--OK FROM PED TO HOME-- | BRIAN | BRIAN | | EUG | C | 5845537 |
AMERINE HEATING & COOLING LLC | H= | C | 08/27/2018 | Furnace change of equipment letter uploaded to permit images. | RANDYB | RANDYB | | H= | C | 5946682 |
AMERINE HEATING & COOLING LLC | H= | R | 08/15/2018 | OUTSIDE AIR TO FURNACE RETURN TO BE DAMPERED OR MOVED WITHIN 12FT OF BLOWER, NEED FURNACE CHANGE LETTER, INSTALL FURNACE CONDENSATE DRAIN, INSTALL RUBBER COUPLING ON FURNACE EXHAUST PER MANUFACTURES INSTALLATION INSTRUCTIONS PAGE 45, MECHANICAL ROOM LACKS COMBUSTION AIR, CURRENT TRANSFER GRILLS ARE UNDERSIZED, FURNACE VENT TERMINATION IS INCOMPLETE, PROTECT LOW VOLT WIRES AT FURNACE, DRYER EXHAUST HAS BEEN COVERED BY ROOF NOTES: FINISHED BASEMENT, HI/LO GRILLS TO MECHANICAL ROOM, OUTSIDE AIR TO FURNACE RETURN, NO A/C | MATTM | MATTM | | H= | R | 5935105 |
AMERINE HEATING & COOLING LLC | HC | C | 06/19/2018 | RELEASE METER | KYLEW | KYLEW | | HC | C | 5878307 |
AMERINE HEATING & COOLING LLC | HRR | C | 06/19/2018 | | KYLEW | KYLEW | | HRR | C | 5878301 |
AMERINE HEATING & COOLING LLC | HRR | P | 06/18/2018 | THE RETURN PANNING IN THE BASEMENT HAS BEEN DAMAGED BY WATER (POSSIBLY RAIN). ALL OTHER CORRECTIONS HAVE BEEN MADE. | KYLEW | KYLEW | | HRR | P | 5877079 |
AMERINE HEATING & COOLING LLC | HRR | R | 06/15/2018 | Trip fee waived. Support dryer exhaust every 4 feet per 2009 IMC 504.6.2. Fireplace vent to have 3" clearance to framing at its front within the chase per page 38 of fireplace manufacturers installation instructions. | RANDYB | RANDYB | | HRR | R | 5876000 |
AMERINE HEATING & COOLING LLC | HRR | R | 06/13/2018 | Only basement bedroom supply has been dropped to finished ceiling height. No other corrections made. Call inspection when ready. | RANDYB | RANDYB | | HRR | R | 5873443 |
SPRINGS GAS, INC. | HI | C | 06/12/2018 | 10 LB Test okay. 1" Main. 1 Furnace. 1 Water heater. 1 Fireplace. | RANDYB | RANDYB | | HI | C | 5871932 |
AMERINE HEATING & COOLING LLC | HRR | P | 06/12/2018 | Fireplace vent to have 3" clearance to framing at front of vent in chase per page 38 of installation instructions. Add support to master bath water closet exhaust duct. Run or remove exhaust duct for master bathroom exhaust fan. Repair torn basement bathroom exhaust in multiple places. Dryer exhaust cannot be 30 gauge, support every 4 feet. Plans show 6" supply to corner of rec. room by mechanical room wall 5" installed. Drop 6" supply to basement bedroom to finished ceiling height. BY FINAL: Outside air to furnace return to be dampered or be within 12 feet of blower compartment. Need change of equipment letter for furnace. NOTES: Finished basement. Outside air to furnace return (12 feet from blower motor). No A/C. | RANDYB | RANDYB | | HRR | P | 5871921 |
MD SERVICE PLUMBING, INC. | P= | C | 08/30/2018 | pvb ok, finished bsmnt | JOHNS | JOHNS | | P= | C | 5951332 |
MD SERVICE PLUMBING, INC. | PTO | C | 06/12/2018 | correction made | JOHNS | JOHNS | | PTO | C | 5871839 |
MD SERVICE PLUMBING, INC. | PTO | P | 06/08/2018 | nail plate @ washer box trap arm, freeze pro @ garage wall water lines @ mech room, rest ok. note: vtr (3), tempering @ left mstr, finished bsmnt, aav @ bsmnt lav, irrigation stub | JOHNS | JOHNS | | PTO | P | 5868740 |
MD SERVICE PLUMBING, INC. | PB | C | 05/04/2018 | Test ok. | DANR | DANR | | PB | C | 5836381 |