WANER CONSTRUCTION COMPANY, INC. | B= | C | 10/31/2018 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 6011208 |
WANER CONSTRUCTION COMPANY, INC. | B= | P | 10/29/2018 | pending completion of mech final. building okay. Additional Inspections Required (computer generated): MARXAIRE, INC. Mechanical Final Inspection is not Completed yet. | BOBF | BOBF | | B= | P | 6008253 |
WANER CONSTRUCTION COMPANY, INC. | B= | P | 10/05/2018 | Temp CO: pending zoning and mechanical finals ( Expires: 11/4/2018 12:00:00 AM) | RITA | RITA | | B= | P | 5987894 |
WANER CONSTRUCTION COMPANY, INC. | B= | P | 10/04/2018 | pending completion of all other required inspections building okay. Additional Inspections Required (computer generated): External Agency Inspection Z= by TOWNOFMON is not Completed yet (Contact: Tom Martinez at 884-8036), LANDMARK PLUMBING & HEATING, INC. Mechanical Final Inspection is not Completed yet, MARXAIRE, INC. Mechanical Final Inspection is not Completed yet. | BOBF | BOBF | | B= | P | 5985429 |
WANER CONSTRUCTION COMPANY, INC. | BFR | C | 10/04/2018 | letter for structural steel and connections on file | BOBF | BOBF | | BFR | C | 5985427 |
WANER CONSTRUCTION COMPANY, INC. | BBB | C | 10/04/2018 | letter for bond beams on file | BOBF | BOBF | | BBB | C | 5985425 |
WANER CONSTRUCTION COMPANY, INC. | BFN | C | 10/04/2018 | letter for footing and steel on file | BOBF | BOBF | | BFN | C | 5985421 |
WANER CONSTRUCTION COMPANY, INC. | B= | P | 10/03/2018 | need to complete mech and elec finals, need address specific letter for foundation and structural steel, rest of building okay -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection Z= by TOWNOFMON is not Completed yet (Contact: Tom Martinez at 884-8036), BEAR ELECTRIC, INC Electrical Final Inspection is not Completed yet, LANDMARK PLUMBING & HEATING, INC. Mechanical Final Inspection is not Completed yet, MARXAIRE, INC. Mechanical Final Inspection is not Completed yet. | BOBF | BOBF | | B= | P | 5984297 |
WANER CONSTRUCTION COMPANY, INC. | BSP | P | 09/05/2018 | inspection request was changed to BSP, channel to hold exterior metal panels okay | BOBF | BOBF | | BSP | P | 5955396 |
WANER CONSTRUCTION COMPANY, INC. | BIN | P | 07/20/2018 | R-12 rigid at exterior walls okay | BOBF | BOBF | | BIN | P | 5909416 |
WANER CONSTRUCTION COMPANY, INC. | BFR | P | 07/20/2018 | pending other required inspections light metal wall framing at main level and Mezzanine okay | BOBF | BOBF | | BFR | P | 5909409 |
WANER CONSTRUCTION COMPANY, INC. | BSP | P | 07/05/2018 | 6" rigid insulation on roof okay | BOBF | BOBF | | BSP | P | 5893731 |
WANER CONSTRUCTION COMPANY, INC. | BFR | P | 06/26/2018 | plywood on backside of parapet okay | BOBF | BOBF | | BFR | P | 5885481 |
WANER CONSTRUCTION COMPANY, INC. | BFR | P | 06/22/2018 | Reviewed Accessible Elements / pending other required inspections, light metal framing at parapet and infill between structural steel at front of building and floor joists for mezzanine okay / will need eng letters for bond beams at masonry walls, welds and bolt connections at structural steel | BOBF | BOBF | | BFR | P | 5882915 |
WANER CONSTRUCTION COMPANY, INC. | BFI | C | 03/22/2018 | 2" R-10 rigid installed | BOBF | BOBF | | BFI | C | 5796268 |
WANER CONSTRUCTION COMPANY, INC. | BFI | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFI | P | 5772680 |
WANER CONSTRUCTION COMPANY, INC. | BFD | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 5772679 |
WANER CONSTRUCTION COMPANY, INC. | BFT | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5772678 |
WANER CONSTRUCTION COMPANY, INC. | BFN | P | 02/23/2018 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5772677 |
BEAR ELECTRIC, INC | E= | C | 10/03/2018 | | TOMC | TOMC | | E= | C | 5984986 |
ALARM DETECTION SYSTEMS, INC. | E= | C | 09/18/2018 | FIRE ALARM INSPECTION: | BRET | BRET | | E= | C | 5968951 |
ALARM DETECTION SYSTEMS, INC. | ER | C | 09/18/2018 | FIRE ALARM INSPECTION: | BRET | BRET | | ER | C | 5968950 |
BEAR ELECTRIC, INC | ER | C | 09/18/2018 | | BRET | BRET | | ER | C | 5968940 |
BEAR ELECTRIC, INC | ES | P | 09/14/2018 | Commercial Service: 600 amp service ok to energize, replace #6 with #4 cu to ufer | BRET | BRET | | ES | P | 5965839 |
ALARM DETECTION SYSTEMS, INC. | ER | P | 08/21/2018 | FIRE ALARM INSPECTION: 1/2'' emt to boxes for fire alarm in hard lid ceiling only ok | CRAIG | CRAIG | | ER | P | 5941160 |
BEAR ELECTRIC, INC | ER | P | 08/21/2018 | hard lid ceiling only ok | CRAIG | CRAIG | | ER | P | 5941154 |
BEAR ELECTRIC, INC | ER | P | 08/20/2018 | need to call in fire alarm before any more inspections call in | CRAIG | CRAIG | | ER | P | 5939321 |
BEAR ELECTRIC, INC | ER | P | 07/27/2018 | show room floor walls only ok | CRAIG | CRAIG | | ER | P | 5916372 |
BEAR ELECTRIC, INC | ER | P | 07/20/2018 | walls only --------marked on plans | CRAIG | CRAIG | | ER | P | 5909349 |
BEAR ELECTRIC, INC | EUG | C | 06/04/2018 | secondary eug | BRET | BRET | | EUG | C | 5864041 |
BEAR ELECTRIC, INC | ESL | P | 05/08/2018 | Interior slab complete in showroom only. | JOSEPH | JOSEPH | | ESL | P | 5838977 |
BEAR ELECTRIC, INC | EST | R | 04/12/2018 | Temporary Service: need separate permit for temp power ------------ 100 amp 3/w ok | CRAIG | CRAIG | | EST | R | 5814983 |
BEAR ELECTRIC, INC | ESL | P | 04/04/2018 | 3/4" pvc to j boxes ok | CRAIG | CRAIG | | ESL | P | 5807334 |
MARXAIRE, INC. | H= | C | 10/31/2018 | TAB REPORT ATTACHED, SEE IMAGES | BENH | BENH | | H= | C | 6011207 |
MARXAIRE, INC. | H= | P | 10/11/2018 | TAB REPORT NEEDS TO BE FROM NEBB OR TABB CERTIFIED COMPANY OR ENGINEER NEEDS TO STAMP AND APPROVE TAB REPORT | BENH | BENH | | H= | P | 5991608 |
MARXAIRE, INC. | H= | P | 10/05/2018 | PARTIAL PENDING TAB REPORT | BENH | BENH | | H= | P | 5987393 |
LANDMARK PLUMBING AND HEATING, INC. | H= | C | 10/05/2018 | GAS FINAL OK | BENH | BENH | | H= | C | 5987392 |
MARXAIRE, INC. | H= | P | 10/03/2018 | STILL NEED TO SEAL GAP BETWEEN B VENT AND SINGLE WALL CONNECTION PER VENT DETAIL ON PAGE 45 IN MANUFACTURERS INSTRUCTIONS, NEED INSTALLATION INSTRUCTIONS FOR VENTING ON REZNOR UNIT HEATER IN WAREHOUSE, GAS FLEX IS STILL DISCONNECTED FROM REZNOR UNIT HEATER,STILL NEED TO SCREW PIT EXHAUST CURB WHERE DUCT IS PENETRATING CURB ON ROOF, DID NOT SEE CONDENSATE DRAINS FOR RTU INSTALLED YET,NEED GAS METER INSTALLED, STILL NEED TAB REPORT | BENH | BENH | | H= | P | 5984476 |
MARXAIRE, INC. | HD | P | 09/19/2018 | NEED TO SEAL JOINT AND ANNULAR SPACE WHERE B VENT AND SINGLE WALL PIPE COME TOGETHER FOR TUBE HEATERS PER MANUFACTURERS INSTRUCTIONS ON PAGE 45 PER VERTICAL VENT DETAIL, NEED INSTALLATION INSTRUCTIONS FOR WAREHOUSE UNIT HEATER AND COMPLETE VENT TO UNIT HEATER AND ON ROOF AND CONNECT GAS FLEX TO HEATER, SCREW DOWN CURB FOR PIT EXHAUST, NEED 1/2" MESH SCREEN IN DUCT PER PRINT FOR PIT EXHAUST, NO MINI SPLITS INSTALLED, DID NOT SEE CONDENSATE DRAINS FOR RTUS INSTALLED, VENT TERMINATION FOR TUBE HEATER OK, ROOM 107, 108, 110 ABOVE CEILING OK AND BATHROOMS ALL REGISTERS INSTALLED, REMOTE INDICATORS FOR RTU'S TO BE AT FRONT DESK AT FINAL, ALL EXPOSED DUCT IN SHOW ROOM OK | BENH | BENH | | HD | P | 5970167 |
MARXAIRE, INC. | HD | P | 08/17/2018 | M 101 ROOMS 108,109,110,113,114 ABOVE CEILING OK TO INSULATE, WILL NEED TO SEE DIFFUSERS AND FLEX, M 102 MEZZANINE SUPPLY DUCT OK TO INSULATE, NO ROOF TODAY, NO TUBE HEATERS INSTALLED YET, OR VENTS INSPECTED | BENH | BENH | | HD | P | 5938186 |
LANDMARK PLUMBING AND HEATING, INC. | HC | C | 08/16/2018 | RELEASE METER THANKS | BENH | BENH | | HC | C | 5936299 |
LANDMARK PLUMBING AND HEATING, INC. | HI | C | 08/16/2018 | 10 LB TEST OK, 2 1/2" MAIN INSTALLED PER PLAN, 2 RTU, 3 RADIANT TUBE HEATERS, 1 UNIT HEATER | BENH | BENH | | HI | C | 5936288 |
MARXAIRE, INC. | HD | P | 03/23/2018 | NEED PLUMBING AND GAS CONTRACTOR ATTACHED TO PERMIT, 8 INCH PVC FOR ALIGNMENT PIT OK, OK TO COVER BY, FINAL NEED 1/2 INCH MESH SCREEN IN DUCT OPENING AS PER PRINT. | NANCY | NANCY | | HD | P | 5797257 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 09/28/2018 | Correction made. | DANR | DANR | | P= | C | 5979589 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | C | 09/28/2018 | Correction made. | DANR | DANR | | PTO | C | 5979587 |
LANDMARK PLUMBING AND HEATING, INC. | PRD | C | 09/28/2018 | Corrections made, images uploaded from contractor. | DANR | DANR | | PRD | C | 5979583 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 09/27/2018 | Need PRD completed. | DANR | DANR | | P= | P | 5978346 |
LANDMARK PLUMBING AND HEATING, INC. | PRD | P | 09/27/2018 | Need pipe support horizontal pipe (pictures uploaded to next inspection ok), rest ok. | DANR | DANR | | PRD | P | 5978345 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 09/26/2018 | Need to run back flow drain per plan (p501 detail 5), need to complete roof drain inspection, rest ok. | DANR | DANR | | P= | P | 5976959 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 09/26/2018 | Need roof drain test and inspection in car bay to complete PTO, rest ok. | DANR | DANR | | PTO | P | 5976954 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 07/25/2018 | DWV and H2O ok above ceiling at restrooms, note: aav in wall for water station. | TAYLOR | TAYLOR | | PTO | P | 5913258 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 07/20/2018 | in walls DWV and H2O ok at restrooms. | TAYLOR | TAYLOR | | PTO | P | 5909576 |
LANDMARK PLUMBING AND HEATING, INC. | PRD | P | 07/20/2018 | roof and overflow drains ok at showroom. | TAYLOR | TAYLOR | | PRD | P | 5909570 |
LANDMARK PLUMBING AND HEATING, INC. | PRD | P | 06/12/2018 | Under foundation OK | SHANEN | SHANEN | | PRD | P | 5872383 |
LANDMARK PLUMBING AND HEATING, INC. | PB | C | 06/11/2018 | still need to call in roof drains for inspection, vents for grease interceptor ok updated 7/20/18 base complete, roof drains called in on later inspection | JOSEPHD | JOSEPHD | | PB | C | 5870057 |
LANDMARK PLUMBING AND HEATING, INC. | PB | P | 06/06/2018 | grease and sand main line ok still need to see the venting under floor and need roof drains tested and inspected | JOSEPHD | JOSEPHD | | PB | P | 5866270 |
LANDMARK PLUMBING AND HEATING, INC. | PB | P | 05/03/2018 | Sanitary DWV test OK | SHANEN | SHANEN | | PB | P | 5834901 |