HOMEOWNER | B= | C | 02/24/2021 | | JEREMYD | JEREMYD | | B= | C | 6879109 |
HOMEOWNER | B= | P | 02/23/2021 | Install Code Compliant Address Numbers / Missing non-absorbent surface on tub and shower walls to a height of not less than 6 feet above floor - OK to submit photo verification of corrected items / Unfinished Basement - No AC installed - Rear deck. -- Schedule a new Building Final when above items are complete. | JEREMYD | JEREMYD | | B= | P | 6878277 |
HOMEOWNER | BE | C | 04/30/2020 | | LONNYS | LONNYS | | BE | C | 6557365 |
HOMEOWNER | BLA | C | 10/30/2018 | | DALE | DALE | | BLA | C | 6010289 |
HOMEOWNER | BIN | C | 10/15/2018 | | DALE | DALE | | BIN | C | 5994869 |
HOMEOWNER | BIN | R | 10/11/2018 | Complete air barrier at tub / Missing insulation at cantilever back wall of basement | SHAUN | SHAUN | | BIN | R | 5992339 |
HOMEOWNER | BFR | C | 10/11/2018 | Truss calcs on file / Truss laterals completed | SHAUN | SHAUN | | BFR | C | 5992336 |
HOMEOWNER | BFR | P | 10/08/2018 | need copy of truss calcs, not scanned / missing truss laterial thru-out, recheck all / no deck inspection, not complete / ok to insulate | DALE | DALE | | BFR | P | 5988898 |
HOMEOWNER | BSP | P | 09/27/2018 | narrow braced wall and front porch lid ok | DALE | DALE | | BSP | P | 5978745 |
HOMEOWNER | BFD | C | 09/05/2018 | Drain and damp proofing observation received in field | SHAUN | SHAUN | | BFD | C | 5955581 |
HOMEOWNER | BFN | C | 09/05/2018 | Received soils report- Float and isolate / Drain around habitable space / 5% grade / Drain design / Open hole report 1,000 psf / Footing observation / Foundation observation with eufer noted / Drain and damp proofing observation | SHAUN | SHAUN | | BFN | C | 5955580 |
HOMEOWNER | BFT | C | 09/05/2018 | Received soils report- Float and isolate / Drain around habitable space / 5% grade / Drain design / Open hole report 1,000 psf / Footing observation / Foundation observation with eufer noted / Drain and damp proofing observation | SHAUN | SHAUN | | BFT | C | 5955577 |
HOMEOWNER | BSP | P | 09/05/2018 | 3 deck piers okay | SHAUN | SHAUN | | BSP | P | 5955560 |
LONGHORN ELECTRIC, INC. | E= | C | 05/20/2019 | No ac pre rough | JOSEPH | JOSEPH | | E= | C | 6204495 |
LONGHORN ELECTRIC, INC. | ES | C | 07/03/2018 | Residential Overhead: 200-amp 3 Wire service, ok to set meter / | JOSEPH | JOSEPH | | ES | C | 5892563 |
LONGHORN ELECTRIC, INC. | EUG | C | 07/03/2018 | 4/0 URD | JOSEPH | JOSEPH | | EUG | C | 5892562 |
LONGHORN ELECTRIC, INC. | ER | C | 07/03/2018 | Unfinished basement ------- No vac ---- UFER is ir ---- 6/3 al ---- 10/3 | JOSEPH | JOSEPH | | ER | C | 5892443 |
PLAINS HEATING AND AIR CONDITIONING, INC. | H= | C | 11/15/2019 | CORRECTION MADE, SEE IMAGES | BILLS | BILLS | | H= | C | 6400300 |
PLAINS HEATING AND AIR CONDITIONING, INC. | H= | P | 11/14/2019 | FURNACE INTAKE AIR TO BE A MINIMUM OF 12" BELOW WATER HEATER VENT TERMINATION. OK TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. NOTE: UNFINISHED BASEMENT, DIRECT VENT FURNACE, NO A/C, NO OUTSIDE AIR, SOLID FUEL FIREPLACE | BILLS | BILLS | | H= | P | 6399438 |
PLAINS HEATING AND AIR CONDITIONING, INC. | HRR | C | 09/27/2018 | BY FINAL: CONTRACTOR TO SPLICE NEW DUCT DESIGN SHOWING 2 ADDED SUPPLY AIR AT ENTRY AND MASTER BATH ( AS PER JOSH), CONFIRM WATER HEATER VENT CONNECTION IN BASEMENT. NOTE: UNFINISHED BASEMENT, DIRECT VENT FURNACE, NO A/C, NO OUTSIDE AIR | BILLS | BILLS | | HRR | C | 5978333 |
NASRALLAH PLUMBING & HEATING, INC. | HO | C | 09/06/2018 | 10LB TEST OK. 95' OF 1/2" POLY PIPE WITH TRACER WIRE FROM TANK TO REGULATOR LOCATION | BILLS | BILLS | | HO | C | 5956492 |
ABOVE WATER PLUMBING & HEATING, LLC | HI | C | 06/29/2018 | PRESSURE TEST AND PIPING OK - 1" FURNACE - WATER HEATER - RANGE - AT FUTURE INSPECTION VERIFY ALL REGULATORS AND VENTS | JERRYF | JERRYF | | HI | C | 5890514 |
PLAINS HEATING AND AIR CONDITIONING, INC. | HRR | P | 06/29/2018 | DUCT DESIGN DOES NOT MATCH INSTALLED ADDED SUPPLYS IN MASTER BATH ROOM AND ENTRY - B VENT NOT CHASED AT MAIN FLOOR - SEAL ELECTRIC WIRING IN RETURN STUD BAYS - STOPPED INSPECTION - NOT READY - RE INSPECT ALL NOTES: DIRECT FURNACE - NO OSA DESIGNED OR INSTALLED | JERRYF | JERRYF | | HRR | P | 5890510 |
HOMEOWNER | P= | C | 10/14/2020 | Potable water certificate received, clearance at water heater corrected | MALYNDA | MALYNDA | | P= | C | 6741643 |
HOMEOWNER | P= | P | 10/12/2020 | Need potable water certificate, need a minimum of 6" of clearance on pex from water heater vent, rest ok Note: no irrigation | MALYNDA | MALYNDA | | P= | P | 6737529 |
HOMEOWNER | PWO | C | 09/05/2018 | need potable water certification by final, need backflow for yard hydrant in well pit by final | JOSEPHD | JOSEPHD | | PWO | C | 5955507 |
ABOVE WATER PLUMBING & HEATING, LLC | PTO | C | 06/11/2018 | still need pwo and will need backflow at yard hydrant at final, yard hydrant needs to be isolated from all other potable water sources note: unfinished basement, mixing valve under master tub in basement | JOSEPHD | JOSEPHD | | PTO | C | 5870948 |
ABOVE WATER PLUMBING & HEATING, LLC | PB | C | 03/15/2018 | basement drain to sewage ejector, no water run under footer or through wall, will need pwo inspection for outside under ground water line from well to house | TED | TED | | PB | C | 5790215 |
HOMEOWNER | XMS | T | 12/26/2018 | PAID (REC#1566289): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised duct design and duct summary sheets | JUSTINC | JUSTINC | | XMS | T | 6062082 |
HOMEOWNER | XBS | T | 05/17/2018 | PAID (REC#1500932) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Enlarge deck and door | MICHAELA | MICHAELA | | XBS | T | 5847561 |