CONSTRUCTION CONSULTING SOLUTIONS, INC. | B= | C | 12/31/2018 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 6065787 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | B= | P | 12/21/2018 | Crawl space. Additional Inspections Required (computer generated): External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | DALE | DALE | | B= | P | 6061409 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFD | C | 09/06/2018 | | LONNYS | LONNYS | | BFD | C | 5956237 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFN | C | 09/06/2018 | | LONNYS | LONNYS | | BFN | C | 5956236 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BLA | C | 08/24/2018 | | LONNYS | LONNYS | | BLA | C | 5944752 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BIN | C | 08/24/2018 | BFR complete | LONNYS | LONNYS | | BIN | C | 5944519 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFR | C | 08/24/2018 | truss packet on file / correct upper level roof framing spliced in | LONNYS | LONNYS | | BFR | C | 5944518 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFR | R | 08/14/2018 | still need to splice in great room roof framing for omitted windows / still need correct truss packet | LONNYS | LONNYS | | BFR | R | 5933013 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BSP | P | 08/14/2018 | engineer letter for master bedroom header on file / still need to complete BFR items | LONNYS | LONNYS | | BSP | P | 5932814 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BIN | R | 08/13/2018 | need to complete BFR / insulation items OK | LONNYS | LONNYS | | BIN | R | 5931618 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFR | P | 08/13/2018 | still need to splice in upper great room roof framing for omitted windows / still need correct truss packet / all other items OK | LONNYS | LONNYS | | BFR | P | 5931607 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFT | C | 08/13/2018 | footing observation on file | LONNYS | LONNYS | | BFT | C | 5931513 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BIN | R | 08/10/2018 | 2 bedrooms on west side of house need insulation behind electric boxes / missing full insulation in recess above sliding door west wall / complete all BFT paperwork. | NATHAN | NATHAN | | BIN | R | 5930642 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BTR | C | 08/07/2018 | | LONNYS | LONNYS | | BTR | C | 5926788 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFT | P | 07/31/2018 | need footing observation - foundation observation uploaded / footing observation need to address forms and reinforcing / open hole on file 2400 PSF - usable | LONNYS | LONNYS | | BFT | P | 5918567 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFR | R | 07/30/2018 | missing open hole and footing observation to complete BFT / need to splice in omitted upper level great roof windows / need to splice in correct truss packet / girder C3 missing HTS20 SW bedroom at porch side / trusses C2-C missing H2.5s porch side SW bedroom / tie in 2x12 beam over SE to top plate / missing all H2.5s over SE tub roof framing / missing H2.5 left of front entrance / front porch cover missing HTS20 EE / no further inspections prior to BFT being completed | LONNYS | LONNYS | | BFR | R | 5917446 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BIN | P | 07/30/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5917203 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BSP | P | 06/27/2018 | rear great room portal wall and 2nd bedroom narrow braced wall sheathing and blocking OK | LONNYS | LONNYS | | BSP | P | 5886762 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BSP | P | 06/22/2018 | all exterior structural fascia OK | LONNYS | LONNYS | | BSP | P | 5882939 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BSP | P | 05/16/2018 | great room and bedroom #2 narrow braced wall straps OK per S4 detail / still need to inspect sheathing , blocking , and nailing at narrow braced walls | LONNYS | LONNYS | | BSP | P | 5846350 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFD | P | 04/11/2018 | need to complete foundation inspections / drain is entire to sump pit - damp proofing OK | LONNYS | LONNYS | | BFD | P | 5813587 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BSP | P | 04/04/2018 | foundation design on file | LONNYS | LONNYS | | BSP | P | 5806907 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFT | P | 04/03/2018 | still need footing observation and soils | LONNYS | LONNYS | | BFT | P | 5805734 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BSP | P | 04/03/2018 | engineer observation for foundation on file - ufer noted | LONNYS | LONNYS | | BSP | P | 5805730 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFN | P | 03/28/2018 | need soils and footing observations / foundation steel and forms OK - ufer observed / received foundation design 2000 PSF | LONNYS | LONNYS | | BFN | P | 5801000 |
CONSTRUCTION CONSULTING SOLUTIONS, INC. | BFT | R | 03/22/2018 | field cancelled per site rep | LONNYS | LONNYS | | BFT | R | 5796174 |
GONZALES ELECTRIC, LLC | E= | C | 12/19/2018 | | JOHNN | JOHNN | | E= | C | 6057561 |
GONZALES ELECTRIC, LLC | E= | R | 12/11/2018 | pipe to a/c can not have nm cable in it, strap 2" riser, hood not installed, grd hwh t stat,open 4/s box in crawler,--------------------40 amp a/c,ok | JOHNN | JOHNN | | E= | R | 6049333 |
GONZALES ELECTRIC, LLC | ES | C | 07/27/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter , new res | JOHNN | JOHNN | | ES | C | 5917091 |
GONZALES ELECTRIC, LLC | ER | C | 07/27/2018 | will need EUG for cart port, rough,ok----------------------------14/3,12/3,#8 cu, ir ufer | JOHNN | JOHNN | | ER | C | 5917088 |
BESTWAY PLUMBING, INC | H= | C | 12/18/2018 | 3 heat pumps, 2 on demand w/h | DAVIDH | DAVIDH | | H= | C | 6057022 |
BESTWAY PLUMBING, INC | HC | C | 07/27/2018 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5916389 |
BESTWAY PLUMBING, INC | HRR | C | 07/27/2018 | BY FINAL NEED TO SEE VENTS IN CRAWL SPACE TO ON DEMANDS, | DAVIDH | DAVIDH | | HRR | C | 5916387 |
MESA PLUMBING & HEATING INC. | HI | C | 07/27/2018 | 10 lb TEST OK , 3- FIRE PLACE 2- ON DEMAND WATER HEATERS , 1- RANGE. | DAVIDH | DAVIDH | | HI | C | 5916364 |
MESA PLUMBING & HEATING INC. | P= | C | 12/21/2018 | Corrections made | MALYNDA | MALYNDA | | P= | C | 6060472 |
MESA PLUMBING & HEATING INC. | P= | P | 12/20/2018 | Please provide photos of tempering devices for 3 master tubs, rest ok. Note: no irrigation | MALYNDA | MALYNDA | | P= | P | 6059338 |
MESA PLUMBING & HEATING INC. | PTO | C | 07/27/2018 | Crawlspace OK | SHANEN | SHANEN | | PTO | C | 5916583 |
MESA PLUMBING & HEATING INC. | PTO | P | 07/26/2018 | ok for main floor only, verify all vent termination locations @ next inspection, still need crawl space. NOTE: tempering @ all tubs @ crawl space by final (x3), check access panel @ jetted tub @ final | JOHNS | JOHNS | | PTO | P | 5914642 |
MESA PLUMBING & HEATING INC. | PTO | L | 07/25/2018 | Field canceled | SHANEN | SHANEN | | PTO | L | 5913334 |
MESA PLUMBING & HEATING INC. | PB | C | 03/09/2018 | | TAYLOR | TAYLOR | | PB | C | 5784899 |