CMH HOMES INC | B= | C | 07/20/2018 | Cmu wall connection corrected / State Insignia 33296 | TOMN | TOMN | | B= | C | 5909095 |
CMH HOMES INC | BSP | P | 07/20/2018 | Engineer letter for XI2 hold downs on file - Engineer letter for no drain required | JUSTINL | JUSTINL | | BSP | P | 5908937 |
CMH HOMES INC | B= | R | 07/10/2018 | Soils report received - Soils report requires perimeter drain - Need to inspect drain or provide engineer letter stating no drain required - Need open hole referenced in soils report - Need to complete items prior to requesting final inspection | JUSTINL | JUSTINL | | B= | R | 5897399 |
CMH HOMES INC | B= | R | 07/06/2018 | Contact permit counter to provide setters information / contact inspector Nathan 719-327-2957 in regards to soils and required documentation prior to any field inspection. / no inspection performed. | TOMN | TOMN | | B= | R | 5894692 |
CMH HOMES INC | BSP | P | 06/18/2018 | Exterior block and wall reinforcement OK, attachment of CMU at top to home to be inspected at final. | PARKER | PARKER | | BSP | P | 5877058 |
CMH HOMES INC | BTD | P | 04/11/2018 | EXTERIOR BLOCK WALL AND REINFORCEMENT TO BE INSPECTED BY RBD OR ENGINEER WITH LETTER TO BE SUPPLIED TO RBD, PLAN NEEDS TO BE REVISED FOR RECESSED FRONT PORCH INTO CRAWLSPACE, ATTACHMENT REQUIRED TO CMU WALL AT TOP TO HOME PER ENGINEERING WILL NEED INSPECTION AS WELL. beam, marriage line support and ridge connection per plan. | NATHAN | NATHAN | | BTD | P | 5814630 |
CMH HOMES INC | BTD | P | 04/10/2018 | Missing perimeter blocking / Could not verify marriage line fasteners at ridge / Marriage line fasteners OK at underside - OK to seal belly bag at fastener locations / Hold downs OK / Request open hole // Serial number SFW018260TXAB | JUSTINL | JUSTINL | | BTD | P | 5812505 |
CMH HOMES INC | BFT | P | 03/14/2018 | Request open hole - until open hole received pour at own risk / Reinforced footers OK per electronic foundation design / Plans reviewed electronically (UPDATE: Eufer observed at time of footer inspection ) JL 4/19 | JUSTINL | JUSTINL | | BFT | P | 5788513 |
WIREMASTER, LLC | E= | C | 06/22/2018 | a/c installed--40 amp | TIMA | TIMA | | E= | C | 5883644 |
WIREMASTER, LLC | ES | C | 05/18/2018 | Residential Underground: 200 amp 3/w new res. needs meter set | TIMA | TIMA | | ES | C | 5850103 |
WIREMASTER, LLC | ES | R | 05/15/2018 | No changes made | SHELBY | SHELBY | | ES | R | 5844816 |
WIREMASTER, LLC | ES | R | 04/10/2018 | no ufer inspection and rebar that is stubbed up is running through the earth | TIMA | TIMA | | ES | R | 5813266 |
WIREMASTER, LLC | EUG | C | 04/10/2018 | | TIMA | TIMA | | EUG | C | 5813265 |
BOB'S HEATING AND AIR CONDITIONING, INC. | H= | C | 07/03/2018 | Picture of T&P piping termination and insulation removed from condensate pump uploaded to permit images | RANDYB | RANDYB | | H= | C | 5892209 |
BOB'S HEATING AND AIR CONDITIONING, INC. | HSP | P | 07/03/2018 | Picture of water heater T&P piping termination accepted. Cannot cover vents on condensate pump. Contractor verified plug that condensate pump plugs into is connected to the bathroom GFCI. | RANDYB | RANDYB | | HSP | P | 5891981 |
BOB'S HEATING AND AIR CONDITIONING, INC. | H= | P | 06/27/2018 | **UPDATE 7/2/18--Received voice message from Melissa, cannot reach her via phone but will accept pictures of corrections.***Water heater T&P piping cannot terminate into crawlspace. Need freeze protection for condensate pump. A/C Condensate pump to plug into a GFCI protected outlet per pump manufacturer. NOTES: Ventilated crawlspace. Direct vent furnace. Electric water heater. A/C Complete. NO outside air to furnace return. | RANDYB | RANDYB | | H= | P | 5886759 |
WESTMAN HEATING AND REPAIR LLC. | HC | C | 06/20/2018 | | RANDYB | RANDYB | | HC | C | 5879491 |
WESTMAN HEATING AND REPAIR LLC. | HO | C | 06/20/2018 | 10 LB Test okay. 1/2" PE with tracer wire measured at 30 feet. Good for 187,000 BTU's with propane. | RANDYB | RANDYB | | HO | C | 5879489 |
I.L.M. PROPERTIES, LLC | HI | C | 04/11/2018 | 10 lb test ok. Will be propane. | MARK | MARK | | HI | C | 5814452 |
I.L.M. PROPERTIES, LLC | HRR | C | 04/11/2018 | Note: MFG home on foundation. No a/c. | MARK | MARK | | HRR | C | 5814441 |
JJ LAY COMPANY | P= | C | 06/08/2018 | | JACK | JACK | | P= | C | 5869661 |
JJ LAY COMPANY | PTO | C | 06/08/2018 | | JACK | JACK | | PTO | C | 5869658 |