WYKOTA CONSTRUCTION INC. | B= | C | 06/20/2019 | All other required Final inspections are complete. (This is a computer generated result) | DAKOTAB | DAKOTAB | | B= | C | 6237546 |
WYKOTA CONSTRUCTION INC. | B= | P | 06/11/2019 | Items corrected. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DAKOTAB | DAKOTAB | | B= | P | 6226889 |
WYKOTA CONSTRUCTION INC. | B= | P | 06/10/2019 | Temp CO: all partials ( Expires: 7/10/2019 12:00:00 AM) | JANE | JANE | | B= | P | 6225430 |
WYKOTA CONSTRUCTION INC. | B= | P | 06/07/2019 | Gutters and downspouts have been installed. Rear garage service door concrete landing exceeds 2% slope. Voids noticed under front of landing. -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | CHUCK | CHUCK | | B= | P | 6224679 |
WYKOTA CONSTRUCTION INC. | B= | P | 06/04/2019 | Still need gutters, downspouts and tip outs - House furnished prior to CO - Please contact Senior inspector Jeremy Anderson prior to scheduling any further inspections -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TIMOTHYS | TIMOTHYS | | B= | P | 6220066 |
WYKOTA CONSTRUCTION INC. | BSP | P | 06/04/2019 | Rebar for column pad in basement ok per plan | TIMOTHYS | TIMOTHYS | | BSP | P | 6220063 |
WYKOTA CONSTRUCTION INC. | BLA | C | 05/15/2019 | Lath OK - lower half of front elevation and rear deck/cover columns only. | CHUCK | CHUCK | | BLA | C | 6200673 |
WYKOTA CONSTRUCTION INC. | B= | P | 03/08/2019 | osb is dried in but still needs siding and stone, soffits installed at porches, handrails okay / still need to complete deck, gutters, downspouts and permanent address -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 6128121 |
WYKOTA CONSTRUCTION INC. | B= | R | 03/05/2019 | air barriers installed over insulation and guard installed at front porch, other previous items not done / please not handrails to be between 34 and 38" throughout. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | R | 6124523 |
WYKOTA CONSTRUCTION INC. | B= | T | 03/04/2019 | PAID (REC#1580287): exposed osb on exterior / provide guard on front porch where fall is greater than 30" within 36" of porch / missing gutter / soffits for front and rear porch not installed / provide handrail at garage to house stairs / fire tape drywall in garage / deck not complete ( doors to deck are guarded) / handrail to basement to be continuous / provide air barrier over insulation in unfinished storage in basement / need to complete frame / amended 3/4/2019- missing gutters and downspouts / need permanent address posted on house | BOBF | BOBF | | B= | T | 6123880 |
WYKOTA CONSTRUCTION INC. | BFR | P | 03/04/2019 | design for beam support in basement on file | BOBF | BOBF | | BFR | P | 6123047 |
WYKOTA CONSTRUCTION INC. | BFR | R | 02/28/2019 | need to upload beam and attachment detail for south beam - beam and attachment to foundation per stamped design reviewed on site and OK / north beam and post not sitting on pad - need verification of pad or updated design for as built conditions | LONNYS | LONNYS | | BFR | R | 6119915 |
WYKOTA CONSTRUCTION INC. | B= | R | 02/22/2019 | not ready / complete bfr / complete all other inspections. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. | DALE | DALE | | B= | R | 6114996 |
WYKOTA CONSTRUCTION INC. | BFR | T | 12/05/2018 | PAID (REC#1577770): lvl beams are not installed per revised eng drawing, all other items okay | BOBF | BOBF | | BFR | T | 6043228 |
WYKOTA CONSTRUCTION INC. | BIN | P | 12/05/2018 | pending completion of frame, insulation okay | BOBF | BOBF | | BIN | P | 6043226 |
WYKOTA CONSTRUCTION INC. | BFN | C | 12/05/2018 | letter for steel and eufer on file | BOBF | BOBF | | BFN | C | 6042917 |
WYKOTA CONSTRUCTION INC. | BSP | P | 12/05/2018 | revised floor design to use LVL beams | BOBF | BOBF | | BSP | P | 6042916 |
WYKOTA CONSTRUCTION INC. | BFR | P | 12/04/2018 | still need to block garage door brackets / need to finish point loads to foundation, need pad poured and monopost installed / need to letter for foundation, need letter for LVL beams in basement | BOBF | BOBF | | BFR | P | 6042019 |
WYKOTA CONSTRUCTION INC. | BSP | P | 12/03/2018 | pad to support post in basement okay | BOBF | BOBF | | BSP | P | 6040940 |
WYKOTA CONSTRUCTION INC. | BIN | R | 11/29/2018 | need to complete frame and foundation inspections, no inspection | BOBF | BOBF | | BIN | R | 6037875 |
WYKOTA CONSTRUCTION INC. | BSP | R | 11/29/2018 | pad dimensions to be 44" x 44" x 12" / actual dimensions 43" x 39" x 12", need to expand hole to plan | BOBF | BOBF | | BSP | R | 6037852 |
WYKOTA CONSTRUCTION INC. | BFR | P | 11/27/2018 | still need eng letter for foundation / block garage door brackets / isolate 2x4s from slab at 1 car garage / 3 - 2x8 header at garage service door / draftstop throughout / 2 hts 20 at 3 LVL beam supporting rear porch trusses / missing stairs to basement / missing laterals at B6, B7, B9 and C5 trusses / provide eng letter for LVL's used in lieu of steel beams / missing pad and monopost supporting steel beam at back of house complete door framing at interior bearing wall / carry point loads to foundation / missing lags at deck ledger, requires blocking behind rim for full penetration / block edges of all shear walls throughout / | BOBF | BOBF | | BFR | P | 6035368 |
WYKOTA CONSTRUCTION INC. | BFI | C | 05/14/2018 | R10 installed / | BOBF | BOBF | | BFI | C | 5844217 |
WYKOTA CONSTRUCTION INC. | BFD | C | 05/14/2018 | exterior / usable / drains to sump pit at southwest corner of basement | BOBF | BOBF | | BFD | C | 5844212 |
WYKOTA CONSTRUCTION INC. | BFT | C | 04/11/2018 | Reinforced footing forms OK -- Check pads at walls -- Need copy of stamped foundation design at next inspections | DAKOTAB | DAKOTAB | | BFT | C | 5813845 |
WYKOTA CONSTRUCTION INC. | BFT | R | 04/06/2018 | not ready, forms not set up | BOBF | BOBF | | BFT | R | 5810633 |
WYKOTA CONSTRUCTION INC. | BSP | P | 03/28/2018 | open hole 2000# on file / exterior usable / 10% slope / 10% slope | BOBF | BOBF | | BSP | P | 5800761 |
HIGH MOUNTAIN ELECTRIC INC. | E= | C | 02/21/2019 | no a/c | TOMC | TOMC | | E= | C | 6113322 |
HIGH MOUNTAIN ELECTRIC INC. | ER | C | 11/26/2018 | | TOMC | TOMC | | ER | C | 6033690 |
HIGH MOUNTAIN ELECTRIC INC. | ES | C | 11/20/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 6031114 |
HIGH MOUNTAIN ELECTRIC INC. | ER | P | 11/20/2018 | need fireplaces installed ----1 - #6 , 2 - #10 , no mcc , no central vac , partial finish basement | TOMC | TOMC | | ER | P | 6031102 |
HIGH MOUNTAIN ELECTRIC INC. | ER | R | 10/23/2018 | plumbing and duct work must be installed prior to electrical rough inspection, front columns not framed, exterior lighting boxes missing ground clips | BRET | BRET | | ER | R | 6003819 |
HIGH MOUNTAIN ELECTRIC INC. | EUG | C | 07/25/2018 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 5914234 |
SIERRA MECH, INC | H= | C | 02/27/2019 | NOTES: DIRECT VENT FURNACE | BENH | BENH | | H= | C | 6119061 |
SIERRA MECH, INC | H= | P | 02/22/2019 | NEED TO CONDENSATE DRAIN COMPLETED NOTES: DIRECT VENT BOILER | BENH | BENH | | H= | P | 6114629 |
WYKOTA CONSTRUCTION INC. | HC | C | 12/27/2018 | OK FOR METER | JON | JON | | HC | C | 6064238 |
SIERRA MECH, INC | HWP | C | 12/14/2018 | Main level pressure test ok. Secured up. | JEFFL | JEFFL | | HWP | C | 6053192 |
WYKOTA CONSTRUCTION INC. | HRR+ | C | 12/03/2018 | | BENH | BENH | | HRR+ | C | 6041085 |
WYKOTA CONSTRUCTION INC. | HV | R | 11/29/2018 | NEED TO CALL IN PROPER INSPECTION HRR +, FIREPLACE FRAMING ON MAIN LEVEL IS INCOMPLETE | BENH | BENH | | HV | R | 6037847 |
WYKOTA CONSTRUCTION INC. | HSP | P | 11/27/2018 | NEED TO CALL IN FOR A HRR+ INSPECTION PRIOR TO ON SITE INSPECTION | ANDREWP | ANDREWP | | HSP | P | 6034560 |
WYKOTA CONSTRUCTION INC. | HRR+ | P | 11/26/2018 | NEED PROPER FRAMING ON MAIN LEVEL FIRE PLACE , NEED VENTS HOOKED UP TO BOTH FIRE PLACES | ANDREWP | ANDREWP | | HRR+ | P | 6033619 |
WYKOTA CONSTRUCTION INC. | HI | C | 11/26/2018 | 10 LB TEST OK , 1 1/4 INCH MAIN , 1 BOILER , 2 FIRE PLACES , 1 BBQ , 1 RANGE | ANDREWP | ANDREWP | | HI | C | 6033618 |
WYKOTA CONSTRUCTION INC. | HRR | C | 11/21/2018 | | JEFFL | JEFFL | | HRR | C | 6031869 |
WYKOTA CONSTRUCTION INC. | HRR | P | 11/19/2018 | Bath exhaust not complete. ***Verify boiler exhaust in basement at final.*** | JEFFL | JEFFL | | HRR | P | 6029369 |
WYKOTA CONSTRUCTION INC. | P= | C | 02/28/2019 | no irrigation stub, finished bsmnt, tempering @ unfinished bsmnt side under mstr tub | JOHNS | JOHNS | | P= | C | 6120382 |
WYKOTA CONSTRUCTION INC. | P= | P | 02/22/2019 | ok for main level jack and jill bath and mstr toilet only, still need remainder to include vtr / hose bibs / irrigation. NOTE: potable water cert sent to scanning | JOHNS | JOHNS | | P= | P | 6114339 |
WYKOTA CONSTRUCTION INC. | PWO | C | 12/10/2018 | check sleeve through foundation wall in mech room by final, need certificate of potable water. | TAYLOR | TAYLOR | | PWO | C | 6047619 |
WYKOTA CONSTRUCTION INC. | PTO | C | 11/16/2018 | | TAYLOR | TAYLOR | | PTO | C | 6028016 |
WYKOTA CONSTRUCTION INC. | PTO | P | 11/15/2018 | support vents in attic, anchor closet flange, low test DWV, missing nail protection through out, re- grade vent for basement bath, rest ok, finished basement, check shower trap in ceiling above mech room and aav at floor drain. | TAYLOR | TAYLOR | | PTO | P | 6026686 |
CASCADE PLUMBING & HEATING | PB | C | 09/07/2018 | | TAYLOR | TAYLOR | | PB | C | 5958327 |
CASCADE PLUMBING & HEATING | PB | P | 08/23/2018 | no corrections made. | TAYLOR | TAYLOR | | PB | P | 5943391 |
CASCADE PLUMBING & HEATING | PB | P | 08/08/2018 | need 6 inch sleeve through foundation wall, re- grade drain for floor drain, rest ok, note: no water service at this time. | TAYLOR | TAYLOR | | PB | P | 5928032 |