RICHMOND AMERICAN HOMES | B= | C | 06/26/2018 | Items corrected | TIMOTHYS | TIMOTHYS | | B= | C | 5885104 |
RICHMOND AMERICAN HOMES | BFN | C | 06/26/2018 | | TIMOTHYS | TIMOTHYS | | BFN | C | 5885103 |
RICHMOND AMERICAN HOMES | B= | P | 06/25/2018 | still need to complete foundation inspection - see comments from BFN dated 18MAY18 -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5884336 |
RICHMOND AMERICAN HOMES | B= | R | 06/22/2018 | missing handrail to 2nd floor / seal penetrations at garage ceiing | DALE | DALE | | B= | R | 5882741 |
RICHMOND AMERICAN HOMES | BIN | C | 06/22/2018 | | DALE | DALE | | BIN | C | 5882739 |
RICHMOND AMERICAN HOMES | BFR | C | 06/22/2018 | | DALE | DALE | | BFR | C | 5882729 |
RICHMOND AMERICAN HOMES | BIN | P | 05/24/2018 | complete bfr | DALE | DALE | | BIN | P | 5854611 |
RICHMOND AMERICAN HOMES | BFR | P | 05/24/2018 | frame has been inspected with 40# plans rbd stamped plans on site / need uploaded and new plot plan | DALE | DALE | | BFR | P | 5854610 |
RICHMOND AMERICAN HOMES | BFR | P | 05/21/2018 | HUS26 hangers need 16d nails at girder truss, front of house / solid block at tji at crawl space at beam / glue shims under beam at crawl space / no rear deck | DALE | DALE | | BFR | P | 5850850 |
RICHMOND AMERICAN HOMES | BFR | R | 05/18/2018 | canceled by contractor | DALE | DALE | | BFR | R | 5849196 |
RICHMOND AMERICAN HOMES | BFT | C | 05/18/2018 | Engineers observation Letter on file / Soils report on file / ufer in / 2500 psf / float 2" / 10% grade | DALE | DALE | | BFT | C | 5848875 |
RICHMOND AMERICAN HOMES | BFN | P | 05/18/2018 | need foundation design / Engineers observation Letter on file / | DALE | DALE | | BFN | P | 5848869 |
RICHMOND AMERICAN HOMES | BFD | C | 05/18/2018 | drain to pit / dampproofing ok / Engineers observation Letter on file / | DALE | DALE | | BFD | C | 5848860 |
RICHMOND AMERICAN HOMES | BSP | P | 04/17/2018 | exterior shear ok | DALE | DALE | | BSP | P | 5818808 |
RICHMOND AMERICAN HOMES | BSP | P | 04/16/2018 | missing straps at rear window, detail, 541.ws on SD page | DALE | DALE | | BSP | P | 5817527 |
RICHMOND AMERICAN HOMES | BSP | P | 04/13/2018 | shear inspection need straps per shear page detail 541.ws on SD page / will need 40# plans in computer | DALE | DALE | | BSP | P | 5816327 |
RICHMOND AMERICAN HOMES | BSP | P | 03/21/2018 | damp proofing ok / complete bft bfn bfd | DALE | DALE | | BSP | P | 5794812 |
RICHMOND AMERICAN HOMES | BFI | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5780044 |
RICHMOND AMERICAN HOMES | BFD | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5780043 |
RICHMOND AMERICAN HOMES | BFT | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5780042 |
RICHMOND AMERICAN HOMES | BFN | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5780041 |
DELMARK ELECTRIC INC | E= | C | 06/21/2018 | 15 amp ac | JOSEPH | JOSEPH | | E= | C | 5881931 |
DELMARK ELECTRIC INC | E= | R | 06/19/2018 | ac breaker to big ---------- max ac is 15 amp | CRAIG | CRAIG | | E= | R | 5879185 |
DELMARK ELECTRIC INC | ES | C | 05/16/2018 | Residential Underground: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5847231 |
DELMARK ELECTRIC INC | ER | C | 05/16/2018 | non-ir ufer (needs to be out of garage space by final), no mcc's, no vac, crawler | MATTHEW | MATTHEW | | ER | C | 5847229 |
DELMARK ELECTRIC INC | EUG | C | 04/03/2018 | 4/urd | TOMC | TOMC | | EUG | C | 5806469 |
TOM JOHNSON, INC. | H= | C | 06/21/2018 | CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, FULL A/C, OUTSIDE AIR WITH DAMPER TO RETURN DUCT, HIGH/LOW GRILLES AT MECHANICAL CLOSET | BILLS | BILLS | | H= | C | 5882035 |
TOM JOHNSON, INC. | H= | P | 06/19/2018 | MECHANICAL CLOSET LACKS COMBUSTION AIR. 2 UPPER LEVEL BEDROOMS NEED RETURN AIR PATHWAY, OUTSIDE AIR NEEDS DAMPER. DUCT LEAKAGE REPORT RECEIVED NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, FULL A/C, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | H= | P | 5878786 |
TOM JOHNSON, INC. | HC | C | 04/24/2018 | RELEASE METER | DUSTINS | DUSTINS | | HC | C | 5825793 |
TOM JOHNSON, INC. | HRR | C | 04/24/2018 | Need return air from crawlspace by final. NOTE: Outside air to furnace return, direct vent furnace, Coil only, Conditioned crawlspace. | DUSTINS | DUSTINS | | HRR | C | 5825789 |
SPRINGS GAS, INC. | HI | C | 04/23/2018 | 10lb test ok 1" @ 50' 1 range, 1 furnace, 1 water heater | JOSEPHD | JOSEPHD | | HI | C | 5824443 |
CONFIDENCE PLUMBING CO., INC | P= | C | 06/15/2018 | note: pvb installed | JOSEPHD | JOSEPHD | | P= | C | 5876456 |
CONFIDENCE PLUMBING CO., INC | PTO | C | 04/24/2018 | | JOSEPHD | JOSEPHD | | PTO | C | 5825043 |
CONFIDENCE PLUMBING CO., INC | PTO | P | 04/23/2018 | need to see water pipe re-tested didnt see a gauge any place, sizing ok | JOSEPHD | JOSEPHD | | PTO | P | 5824442 |
CONFIDENCE PLUMBING CO., INC | PTO | P | 04/18/2018 | cold water under sized, rest ok note: irrigation stub, aav @ utility room floor drain | JOSEPHD | JOSEPHD | | PTO | P | 5819929 |