RICHMOND AMERICAN HOMES | B= | C | 06/14/2018 | | DALE | DALE | | B= | C | 5874537 |
RICHMOND AMERICAN HOMES | B= | R | 06/13/2018 | sheetrock and tape beam at 3rd car / crawl space, no deck, slab | DALE | DALE | | B= | R | 5873220 |
RICHMOND AMERICAN HOMES | BIN | C | 05/09/2018 | | DALE | DALE | | BIN | C | 5839847 |
RICHMOND AMERICAN HOMES | BFR | C | 05/09/2018 | | DALE | DALE | | BFR | C | 5839846 |
RICHMOND AMERICAN HOMES | BSP | P | 05/09/2018 | front porch frame and post ok | DALE | DALE | | BSP | P | 5839836 |
RICHMOND AMERICAN HOMES | BFR | P | 05/07/2018 | front porch missing post / rear porch frame and posts ok / missing roll blocks at garage / missing h.2.5.a at garage mid-point bearing / ok to insulate / no deck at rear | DALE | DALE | | BFR | P | 5837616 |
RICHMOND AMERICAN HOMES | BSP | P | 04/13/2018 | exterior shear ok / will need 40# plans in computer | DALE | DALE | | BSP | P | 5816331 |
RICHMOND AMERICAN HOMES | BSP | P | 04/11/2018 | # 3 shear calls for 10d nailing at bottom plate and edge nailing 6" oc | DALE | DALE | | BSP | P | 5813751 |
RICHMOND AMERICAN HOMES | BFT | C | 04/11/2018 | Engineers observation Letter on file / Soils report on file / 2500 psf / float 2" / 10% grade | DALE | DALE | | BFT | C | 5813470 |
RICHMOND AMERICAN HOMES | BFD | P | 04/11/2018 | Pending verification of connection to underdrain via photo or reinspection / | DALE | DALE | | BFD | P | 5813452 |
RICHMOND AMERICAN HOMES | BFN | P | 04/11/2018 | need foundation design / Engineers observation Letter on file / | DALE | DALE | | BFN | P | 5813450 |
RICHMOND AMERICAN HOMES | BSP | P | 03/16/2018 | damp proofing ok | DALE | DALE | | BSP | P | 5791375 |
RICHMOND AMERICAN HOMES | BFI | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5780055 |
RICHMOND AMERICAN HOMES | BFD | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5780054 |
RICHMOND AMERICAN HOMES | BFN | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5780052 |
RICHMOND AMERICAN HOMES | BFT | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5780053 |
DELMARK ELECTRIC INC | E= | C | 06/12/2018 | no ac | CRAIG | CRAIG | | E= | C | 5872529 |
DELMARK ELECTRIC INC | ES | C | 05/02/2018 | Residential Underground: 200 - amp 3 Wire new service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5834253 |
DELMARK ELECTRIC INC | ER | C | 05/02/2018 | | CRAIG | CRAIG | | ER | C | 5834252 |
DELMARK ELECTRIC INC | ES | R | 04/26/2018 | Seal service nipple -------- Notes: Rest of 200 amp service good. | JOSEPH | JOSEPH | | ES | R | 5828675 |
DELMARK ELECTRIC INC | ER | R | 04/26/2018 | Install & wire fireplace ----------- Add receptacle (I marked location) S.E. of kitchen island. --------- Install running boards at both attic accesses. ---------- Notes: Crawler -------- 6/3 al ---- 10/3 --- No vac ---- UFER is not ir | JOSEPH | JOSEPH | | ER | R | 5828673 |
DELMARK ELECTRIC INC | EUG | C | 04/03/2018 | 4/0 urd | TOMC | TOMC | | EUG | C | 5806460 |
TOM JOHNSON, INC. | H= | C | 06/12/2018 | | MATTM | MATTM | | H= | C | 5871369 |
TOM JOHNSON, INC. | H= | P | 06/11/2018 | NEED SUPPLY REGISTERS WITHOUT DAMPERS OR MECHANICALLY BLOCKED OPEN VENTS INSTALLED IN CRAWLSPACE. OK TO ATTACH PICTURES AT NEXT INSPECTION REQUEST. DUCT LEAKAGE REPORT RECEIVED. NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, A/C ROUGH LINESET ONLY, 6" OUTSIDE AIR WITH DAMPER TO RETURN DUCT, 8" COMBUSTION AIR FROM VENTED ATTIC TO MECHANICAL CLOSET | BILLS | BILLS | | H= | P | 5870662 |
TOM JOHNSON, INC. | HC | C | 05/04/2018 | RELEASE METER | LIDO | LIDO | | HC | C | 5836044 |
TOM JOHNSON, INC. | HRR | C | 05/04/2018 | CORRECTIONS MADE . | LIDO | LIDO | | HRR | C | 5836032 |
TOM JOHNSON, INC. | HRR | P | 05/03/2018 | NO CORRECTIONS MADE . MET WITH SUPER ON JOB SITE (PATRICK) WENT OVER CODE ISSUES . Water heater blocking furnaces 30" service clearance. Water heater lacking 30" service clearance. | LIDO | LIDO | | HRR | P | 5834818 |
TOM JOHNSON, INC. | HRR | R | 05/02/2018 | Water heater blocking furnaces 30" service clearance. Water heater lacking 30" service clearance. | RANDYB | RANDYB | | HRR | R | 5833536 |
SPRINGS GAS, INC. | HI | C | 05/01/2018 | 10LB TEST OK 1" MAIN 1 FURNACE, 1 WATER HEATER, 1 FIREPLACE | MATTM | MATTM | | HI | C | 5832170 |
TOM JOHNSON, INC. | HRR | T | 04/26/2018 | PAID (REC#1497368) 4th inspection required, Fees apply, do not reschedule until water heater has been installed. Need to verify water heater vent meets mfg requirements prior to completing the rough inspection. Vent for furnace ok. | MARK | MARK | | HRR | T | 5828953 |
TOM JOHNSON, INC. | HRR | P | 04/19/2018 | Need water heater manual on site to check for approved venting materials. Furnace vent was cut in mechanical room and need to check connections by final. | DUSTINS | DUSTINS | | HRR | P | 5821903 |
TOM JOHNSON, INC. | HRR | P | 04/12/2018 | Where is water heater vent? Furnace vent needs insulation in attic. Duct leakage report by final. NOTE: Outside air with electronic damper in mechanical room, A/C rough coil and line set only, direct vent furnace, conditioned crawlspace. | DUSTINS | DUSTINS | | HRR | P | 5815860 |
CONFIDENCE PLUMBING CO., INC | P= | C | 06/12/2018 | 3/4'' pvb installed | TED | TED | | P= | C | 5872509 |
CONFIDENCE PLUMBING CO., INC | P= | R | 06/11/2018 | install sprinkler backflow, rest ok | TED | TED | | P= | R | 5870790 |
CONFIDENCE PLUMBING CO., INC | PTO | C | 05/04/2018 | correction made at water heater spun to get clearance for service, will check for clearance at for furnace at final | JOSEPHD | JOSEPHD | | PTO | C | 5835888 |
CONFIDENCE PLUMBING CO., INC | PTO | P | 05/03/2018 | need 30" of clearance for water heater service and blocking in furnace, rest ok note: aav @ utility room, irrigation stub | JOSEPHD | JOSEPHD | | PTO | P | 5835387 |