RICHMOND AMERICAN HOMES | B= | C | 07/24/2018 | corrections complete | SCOTTS | SCOTTS | | B= | C | 5911896 |
RICHMOND AMERICAN HOMES | B= | P | 07/23/2018 | seal vapor barrier in crawlspace per soils report -- seal garage wall penetration -- crawlspace/no deck -- Schedule a new Building Final when above items are complete. | SCOTTS | SCOTTS | | B= | P | 5911452 |
RICHMOND AMERICAN HOMES | BIN | C | 06/19/2018 | | LONNYS | LONNYS | | BIN | C | 5878998 |
RICHMOND AMERICAN HOMES | BFR | C | 06/19/2018 | | LONNYS | LONNYS | | BFR | C | 5878988 |
RICHMOND AMERICAN HOMES | BIN | R | 06/15/2018 | complete BFR -- seal air barriers | SCOTTS | SCOTTS | | BIN | R | 5876494 |
RICHMOND AMERICAN HOMES | BFR | T | 06/15/2018 | PAID (REC#1508049): still missing kings on landing header | SCOTTS | SCOTTS | | BFR | T | 5876490 |
RICHMOND AMERICAN HOMES | BIN | R | 06/14/2018 | complete BFR | SCOTTS | SCOTTS | | BIN | R | 5874452 |
RICHMOND AMERICAN HOMES | BFR | R | 06/14/2018 | all corrections not complete | SCOTTS | SCOTTS | | BFR | R | 5874442 |
RICHMOND AMERICAN HOMES | BFT | C | 06/14/2018 | long form soils/open ex on file | SCOTTS | SCOTTS | | BFT | C | 5874411 |
RICHMOND AMERICAN HOMES | BSP | P | 06/08/2018 | porch post connections ok | SCOTTS | SCOTTS | | BSP | P | 5869588 |
RICHMOND AMERICAN HOMES | BFR | R | 06/05/2018 | need to complete foundation inspections before any further inspections / landing window missing 2nd K EE and blocking / upper level headers shear and face nailing incomplete per 604 detail / missing 3rd 2x10 header mail level rear slider / crawler opening missing several hangers / UPDATE: upon further inspection nailing incomplete at bearing block at B3 girder - detail 493 | LONNYS | LONNYS | | BFR | R | 5865381 |
RICHMOND AMERICAN HOMES | BFD | P | 06/05/2018 | foundation damp proofing OK / need soils report to complete BFT | LONNYS | LONNYS | | BFD | P | 5865379 |
RICHMOND AMERICAN HOMES | BSP | P | 06/05/2018 | received foundation design - 3000PSF | LONNYS | LONNYS | | BSP | P | 5865369 |
RICHMOND AMERICAN HOMES | BSP | P | 06/05/2018 | document upload | LONNYS | LONNYS | | BSP | P | 5864215 |
RICHMOND AMERICAN HOMES | BFD | P | 06/05/2018 | need to complete BFT and BFN / need to verify damp proofing / drain observation on file / picture of drain tie in on file | LONNYS | LONNYS | | BFD | P | 5864212 |
RICHMOND AMERICAN HOMES | BFN | C | 06/05/2018 | need foundation design / foundation observation on file - ufer noted | LONNYS | LONNYS | | BFN | C | 5864207 |
RICHMOND AMERICAN HOMES | BFT | P | 06/05/2018 | need soils report / open hole on file -3000PSF - interior drain - 10% / footing observation on file | LONNYS | LONNYS | | BFT | P | 5864204 |
RICHMOND AMERICAN HOMES | BSP | P | 05/07/2018 | shear wall corrections okay / note - need to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5837963 |
RICHMOND AMERICAN HOMES | BSP | R | 05/03/2018 | Interior and exterior shear wall nail spacing incorrect in areas at edges and field. | NOAH | NOAH | | BSP | R | 5834950 |
RICHMOND AMERICAN HOMES | BSP | P | 03/27/2018 | foundation damp proofing OK / need all foundation paperwork | LONNYS | LONNYS | | BSP | P | 5800469 |
RICHMOND AMERICAN HOMES | BFI | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5780087 |
RICHMOND AMERICAN HOMES | BFD | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5780086 |
RICHMOND AMERICAN HOMES | BFT | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5780085 |
RICHMOND AMERICAN HOMES | BFN | P | 03/05/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5780084 |
DELMARK ELECTRIC INC | E= | C | 07/20/2018 | floor box was covered by carpet | CRAIGS | CRAIGS | | E= | C | 5909285 |
DELMARK ELECTRIC INC | E= | R | 07/19/2018 | covered receptacle on the knee wall @ the stairs (up stairs )????------- no A/C at this time | CRAIGS | CRAIGS | | E= | R | 5908333 |
DELMARK ELECTRIC INC | E= | R | 07/17/2018 | garage door opener and outlet on the south wall of garage not gfci protected --- complete re inspection required --- please hot check whole house | CRAIGS | CRAIGS | | E= | R | 5904883 |
DELMARK ELECTRIC INC | ES | C | 05/30/2018 | Residential Underground: 200A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 5859163 |
DELMARK ELECTRIC INC | ER | C | 05/30/2018 | #6 AL to oven/range / 1 - #14 multiwire circuit / Non Irreversible UFER connection / No Cent Vac / crawler/ 1 - #10/3 / receptacle in attic by access / | MIGUEL | MIGUEL | | ER | C | 5859154 |
TOM JOHNSON, INC. | H= | C | 07/17/2018 | NOTES: 2 - TRANSFER GRILLS, HIGH AND LOW, ON THE MECHANICAL ROOM WALL | JEFFB | JEFFB | | H= | C | 5904911 |
TOM JOHNSON, INC. | HC | C | 06/04/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 5863073 |
TOM JOHNSON, INC. | HRR | C | 06/04/2018 | NEEDED BY FINAL-- VERIFY PROPER WATER HEATER VENT TERMINATION CLEARANCES. note: conditioned crawl space, outside air to return with motorized damper, direct vent furnace, indirect vent water heater, no a/c. | PAULO | PAULO | | HRR | C | 5863066 |
TOM JOHNSON, INC. | HRR | P | 06/01/2018 | SUPPORT ALL BATHROOM EXHAUST FLEX ON UPPER LEVEL. | MATTM | MATTM | | HRR | P | 5861493 |
TOM JOHNSON, INC. | HRR | P | 05/24/2018 | Complete bath exhaust insulation to fans in upper bathrooms. BY FINAL: Ensure water heater vent terminates 1 foot above furnace intake vent. NOTES: Conditioned/ventilated crawlspace. Outside air to furnace return with motorized damper. Direct vent furnace. No A/C. | RANDYB | RANDYB | | HRR | P | 5854667 |
SPRINGS GAS, INC. | HI | C | 05/21/2018 | 10# test ok. note: 1" main at 30' to 1- furnace and 1- water heater. | PAULO | PAULO | | HI | C | 5850834 |
CONFIDENCE PLUMBING CO., INC | P= | C | 07/20/2018 | 3/4'' pvb installed | TED | TED | | P= | C | 5909700 |
CONFIDENCE PLUMBING CO., INC | P= | R | 07/19/2018 | no hot water temp. to fixtures, reinspect all | TED | TED | | P= | R | 5908271 |
CONFIDENCE PLUMBING CO., INC | PTO | C | 05/17/2018 | note: crawlspace, irrigation stub, aav @ utility room | JOSEPHD | JOSEPHD | | PTO | C | 5848697 |