GRB SERVICE SYSTEMS, INC. | B= | C | 07/23/2019 | All other required Final inspections are complete. (This is a computer generated result) | RICHB | RICHB | | B= | C | 6274281 |
GRB SERVICE SYSTEMS, INC. | BE | L | 04/01/2019 | Renewed at 4/1/2019 1:53:33 PM | RITA | RITA | | BE | L | 6151127 |
GRB SERVICE SYSTEMS, INC. | B= | P | 04/26/2018 | Complete pending other Finals. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet, AMEN PLUMBING AND HEATING Mechanical Final Inspection is not Completed yet, VICTORY AIR Mechanical Final Inspection is not Completed yet. | RICHB | RICHB | | B= | P | 5828118 |
GRB SERVICE SYSTEMS, INC. | BFR | P | 03/19/2018 | Framing for interior non-bearing non-rated walls OK pending other Roughs / framing for hardlids OK pending other Roughs / discussed accessible elements / discussed Construction Type being indicated as III-B non-sprinklered - need details for column and beam protection / plans reviewed onsite //// UPDATED COMMENT 3/20/18 - Inspector mistyped Construction Type - plans indicate it is a III-A, so previous comments are accurate | RICHB | RICHB | | BFR | P | 5792641 |
FOSTER ELECTRIC CORPORATION | E= | C | 04/25/2018 | 3-RTU's, 2-50 amp breakers, 1-35 amp breaker with 30 amp fuses at unit | GARYL | GARYL | | E= | C | 5827473 |
FOSTER ELECTRIC CORPORATION | ER | P | 04/18/2018 | above ceilings in sales floor okay | GARYL | GARYL | | ER | P | 5820331 |
FOSTER ELECTRIC CORPORATION | ER | P | 04/18/2018 | wall recept's for signs relocated | GARYL | GARYL | | ER | P | 5820323 |
FOSTER ELECTRIC CORPORATION | ER | R | 04/17/2018 | power poles not ready----show window receptacles need to be within 18 of top of window per nec 210.62 | MIGUEL | MIGUEL | | ER | R | 5819540 |
FOSTER ELECTRIC CORPORATION | ER | P | 04/16/2018 | above grid ceiling, sales floor north of power poles ok | MIGUEL | MIGUEL | | ER | P | 5818018 |
FOSTER ELECTRIC CORPORATION | ES | C | 04/10/2018 | Commercial Service: 400A parallel 4w ok to main---ok to set CTs and meter | MIGUEL | MIGUEL | | ES | C | 5812807 |
FOSTER ELECTRIC CORPORATION | ER | P | 03/19/2018 | walls good/ discussed accessibility with contractor / | MIGUEL | MIGUEL | | ER | P | 5792091 |
VICTORY AIR | H= | C | 07/23/2019 | WALK-IN COOLER IS SELF CONTAINED | BENH | BENH | | H= | C | 6274280 |
VICTORY AIR | HSP | P | 06/28/2019 | NEED HRP INSPECTION FOR LINE SET AND CONDENSATE DRAINS MAY NEED PRESSURE TEST | BENH | BENH | | HSP | P | 6248316 |
AMEN PLUMBING- HEATING | H= | C | 06/28/2019 | MECHANICAL FINAL OK | BENH | BENH | | H= | C | 6248309 |
AMEN PLUMBING- HEATING | HE | L | 06/04/2019 | Renewed at 6/4/2019 8:44:49 AM | TERRI | TERRI | | HE | L | 6218862 |
AMEN PLUMBING- HEATING | HSP | P | 08/27/2018 | NEED TO VERIFY DUCT INSULATION ON ROOF TOP UNITS IN ADDITION TO OTHER ITEMS | JERRYF | JERRYF | | HSP | P | 5945942 |
AMEN PLUMBING- HEATING | H= | P | 05/09/2018 | TAB REPORT RECEIVED STILL NEED OTHER ITEMS ADDRESSED | JERRYF | JERRYF | | H= | P | 5839339 |
AMEN PLUMBING- HEATING | HSP | P | 04/30/2018 | RTU SUPPORT OK STILL NEED OTHER ITEMS ADDRESSED | JERRYF | JERRYF | | HSP | P | 5830368 |
AMEN PLUMBING- HEATING | H= | P | 04/27/2018 | NEED CONSULT ON RTU SUPPORT - NEED THE FOLLOWING - SMOKE SHUT DOWN AND REMOTE INDICATOR - CO 2 SENSORS PER PLAN - TAB REPORT | JERRYF | JERRYF | | H= | P | 5830287 |
AMEN PLUMBING- HEATING | HD | P | 04/06/2018 | ABOVE CEILING IN SALES AND STORAGE AREA OK TO WRAP ONLY - STILL NEED RESTROOM AREA'S AND ROOF INSPECTION - VERIFY SMOKE SHUTDOWN AND CO SENSORS PER PLAN - BEFORE FINAL NEED LETTER FROM MECHANICAL ENGINEER APPROVING EXTERIOR EXHAUST TO INCLUDE MAKE AND MODEL NUMBER | JERRYF | JERRYF | | HD | P | 5810437 |
AMEN PLUMBING- HEATING | P= | C | 04/25/2018 |
| JOHNS | JOHNS | | P= | C | 5826876 |
AMEN PLUMBING- HEATING | PTO | C | 03/19/2018 | per plan. note: vtr ( 1 existing), trap primer, (x2 p trap connection) check water htr / expansion / bfp @ water mtr / and 1" main dcw to water htr @ final | JOHNS | JOHNS | | PTO | C | 5792365 |
AMEN PLUMBING- HEATING | PB | C | 03/14/2018 | gc to attach mech and elec permits, rest ok, per plan, water pre existing @ water entry, all waters over head | JOHNS | JOHNS | | PB | C | 5788143 |
GRB SERVICE SYSTEMS, INC. | XBS | T | 03/28/2018 | PAID (REC#1490186) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Revised type of construction to IIIB | SHELLEY | SHELLEY | | XBS | T | 5801554 |