COMITO BUILDING AND DESIGN, LLC | B= | C | 12/17/2019 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 6429718 |
COMITO BUILDING AND DESIGN, LLC | B= | P | 12/17/2019 | . Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 6429532 |
COMITO BUILDING AND DESIGN, LLC | BLA | C | 03/04/2019 | | NICK | NICK | | BLA | C | 6123410 |
COMITO BUILDING AND DESIGN, LLC | BFR | C | 02/26/2019 | | NICK | NICK | | BFR | C | 6117127 |
COMITO BUILDING AND DESIGN, LLC | BIN | C | 02/21/2019 | | NICK | NICK | | BIN | C | 6113366 |
COMITO BUILDING AND DESIGN, LLC | BSP | R | 02/21/2019 | Need to splice S2 sheet into plans not upload to permit | NICK | NICK | | BSP | R | 6112688 |
COMITO BUILDING AND DESIGN, LLC | BFR | P | 02/21/2019 | Eng letter for welding on file / Still need splice for plans per previous comments | NICK | NICK | | BFR | P | 6112686 |
COMITO BUILDING AND DESIGN, LLC | BFR | P | 02/12/2019 | Still need to install sister 2x10 porch for basement area or splice out of approved plans / Letter for welding does not have Eng or certified welding stamp, please re send letter with one of these stamps / All other framing items completed | NICK | NICK | | BFR | P | 6104435 |
COMITO BUILDING AND DESIGN, LLC | BFR | P | 01/17/2019 | Need to install titan screws for ledger per detail 8 S/5 in garage / No sister 2x10 installed for overhang at low level frame / All other framing and interior shear walls and hold downs OK per approved plans | NICK | NICK | | BFR | P | 6081644 |
COMITO BUILDING AND DESIGN, LLC | BSP | P | 11/12/2018 | All exterior porches and overhangs OK per approved plans | NICK | NICK | | BSP | P | 6022692 |
COMITO BUILDING AND DESIGN, LLC | BSP | P | 09/27/2018 | All exterior shear OK | NICK | NICK | | BSP | P | 5978723 |
COMITO BUILDING AND DESIGN, LLC | BFD | C | 05/04/2018 | | NICK | NICK | | BFD | C | 5835777 |
COMITO BUILDING AND DESIGN, LLC | BFT | C | 05/04/2018 | | NICK | NICK | | BFT | C | 5835776 |
COMITO BUILDING AND DESIGN, LLC | BFN | C | 05/04/2018 | Open hole on file / #3000psf / Drain usable / Isolate and float / Eng letter of observation on file / Eng on file for grounding | NICK | NICK | | BFN | C | 5835775 |
COMITO BUILDING AND DESIGN, LLC | BSP | P | 05/04/2018 | Soils on file | NICK | NICK | | BSP | P | 5835771 |
COMITO BUILDING AND DESIGN, LLC | BFI | C | 05/03/2018 | R-10 at 2' OK | NICK | NICK | | BFI | C | 5835067 |
COMITO BUILDING AND DESIGN, LLC | BFD | P | 05/03/2018 | Need footing and foundation complete / Drain of usable space OK / Damp proof OK / Drain daylights to back of house / Back fill at own risk | NICK | NICK | | BFD | P | 5835059 |
COMITO BUILDING AND DESIGN, LLC | BFN | R | 05/03/2018 | Need Eng letter of observation / Need soils report / Need footing complete | NICK | NICK | | BFN | R | 5835058 |
COMITO BUILDING AND DESIGN, LLC | BFT | R | 05/03/2018 | Need Open hole and Eng letter of observation for footing / Field copy of open hole on site at time of inspection | NICK | NICK | | BFT | R | 5835052 |
HOMERUN ELECTRONICS, INC. | E= | C | 12/17/2019 | load calc accepted | MATTHEW | MATTHEW | | E= | C | 6429350 |
HOMERUN ELECTRONICS, INC. | ES | C | 12/17/2019 | Residential Underground: 200 amp 3/w: new res------- no action needed | MATTHEW | MATTHEW | | ES | C | 6429348 |
HOMERUN ELECTRONICS, INC. | ES | P | 12/16/2019 | Residential Underground: see final. | JOHNN | JOHNN | | ES | P | 6429142 |
HOMERUN ELECTRONICS, INC. | E= | P | 12/16/2019 | per Matt S, need more info on load calc,----------------rest of house is ok, | JOHNN | JOHNN | | E= | P | 6429141 |
HOMERUN ELECTRONICS, INC. | E= | P | 12/13/2019 | load calc submitted is not correct, basement has open neutral in outlets, basement bath outlet at toilet needs gfci, strap 3 nm cables above sub panel, please hot check all of basement, | JOHNN | JOHNN | | E= | P | 6428027 |
HOMERUN ELECTRONICS, INC. | ES | R | 12/13/2019 | see final, | JOHNN | JOHNN | | ES | R | 6428022 |
HOMERUN ELECTRONICS, INC. | E= | R | 12/12/2019 | gfci: laundry, all bath rm outlets, need specs on bath rm tub, has cord, needs gfci, bonding? may need cb lockouts on kitchen appliances if not installed, ran out of time, did not look at basement, | JOHNN | JOHNN | | E= | R | 6426084 |
HOMERUN ELECTRONICS, INC. | ES | R | 12/12/2019 | see final | JOHNN | JOHNN | | ES | R | 6426076 |
HOMERUN ELECTRONICS, INC. | ES | R | 12/12/2019 | need FA permit. | JOHNN | JOHNN | | ES | R | 6424990 |
HOMERUN ELECTRONICS, INC. | E= | R | 12/12/2019 | need FA permit. | JOHNN | JOHNN | | E= | R | 6424981 |
HOMERUN ELECTRONICS, INC. | E= | R | 12/09/2019 | not ready, upload load calc, did not go in house,need FA permit. | JOHNN | JOHNN | | E= | R | 6421171 |
HOMERUN ELECTRONICS, INC. | ES | R | 12/09/2019 | see final | JOHNN | JOHNN | | ES | R | 6421170 |
HOMERUN ELECTRONICS, INC. | ES | P | 01/16/2019 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / --------CHECK load calc on final. | JOHNN | JOHNN | | ES | P | 6080139 |
HOMERUN ELECTRONICS, INC. | ER | C | 01/16/2019 | | JOHNN | JOHNN | | ER | C | 6080133 |
HOMERUN ELECTRONICS, INC. | ES | R | 01/15/2019 | ufer not connected properly, need to upload load calc for service, | JOHNN | JOHNN | | ES | R | 6078812 |
HOMERUN ELECTRONICS, INC. | ER | R | 01/15/2019 | ufer clamp and wire are not installed properly/ floor box needs nm connector and grd connected/ outlet for jet tub needs to face access opening and be not more than 12" away/ upload load calc to permit/ need FA permit---------------------notes: check panels on final,ran 4/0 al to basement sub panel, no floor heat. | JOHNN | JOHNN | | ER | R | 6078787 |
HOMERUN ELECTRONICS, INC. | ER | R | 12/27/2018 | need load calc for service and sub panel, no ufer connected, need all framing complete: above main panel and garage ceiling, confirm dishwasher and trash compactor have dedicated circuits, need smokes wired or FA permit, upstairs bath fan not in yet, --------------------------------notes: 200 amp main: 2: 12/3, 3#6al,1#6cu, --------1/0 al to sub panel:2#6cu,2:12/3, | JOHNN | JOHNN | | ER | R | 6063839 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | H= | C | 12/09/2019 | complete | DAVIDH | DAVIDH | | H= | C | 6421021 |
A & Z MECHANICAL, INC. | H= | C | 12/09/2019 | a/c x 2 unico system finished basement | DAVIDH | DAVIDH | | H= | C | 6421020 |
DAVIS GAS SHOP INC | HO | C | 11/20/2019 | note 10 test ok future firepit | DAVIDH | DAVIDH | | HO | C | 6405886 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HWP | C | 01/24/2019 | 60 lb test ok main and upper floor | DAVIDH | DAVIDH | | HWP | C | 6087320 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 01/15/2019 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 6078448 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 01/15/2019 | 10 lb test ok note 1 1/4" main 1 boiler,bbq ,fireplace and future 1" out back | DAVIDH | DAVIDH | | HI | C | 6078439 |
A & Z MECHANICAL, INC. | HRR | C | 01/15/2019 | 2 unico systems line sets and coils ok bath fans dryer vents ok | DAVIDH | DAVIDH | | HRR | C | 6078428 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HWP | P | 07/17/2018 | 60 LB TEST ON LOWER LEVEL | DAVIDH | DAVIDH | | HWP | P | 5904999 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 12/06/2019 | finished basement, RP installed. | TAYLOR | TAYLOR | | P= | C | 6419387 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 12/20/2018 | finished basement, aav's at both main floor lavs. | TAYLOR | TAYLOR | | PTO | C | 6060327 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 05/16/2018 | | SHANEN | SHANEN | | PB | C | 5847111 |
COMITO BUILDING AND DESIGN, LLC | XBS | T | 02/22/2019 | PAID (REC#1578423): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Delete awning from scope | MICHAELA | MICHAELA | | XBS | T | 6115126 |