JDBUILTHOMESLLC | B= | C | 11/08/2018 | Previous item complete | RICHB | RICHB | | B= | C | 6019923 |
JDBUILTHOMESLLC | B= | P | 11/05/2018 | Need guard installed at upper level covered deck / Final OK otherwise / no AC - finished lower level, covered deck -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | RICHB | RICHB | | B= | P | 6015823 |
JDBUILTHOMESLLC | BLA | C | 07/03/2018 | | LONNYS | LONNYS | | BLA | C | 5892449 |
JDBUILTHOMESLLC | BIN | C | 06/28/2018 | pictures of insulation at rim on file | LONNYS | LONNYS | | BIN | C | 5887999 |
JDBUILTHOMESLLC | BIN | P | 06/26/2018 | insulation incomplete at rim between joists - OK to upload picture upon completion | LONNYS | LONNYS | | BIN | P | 5885239 |
JDBUILTHOMESLLC | BIN | P | 06/22/2018 | insulation missing under main level floor framing | LONNYS | LONNYS | | BIN | P | 5883058 |
JDBUILTHOMESLLC | BFR | C | 06/22/2018 | | LONNYS | LONNYS | | BFR | C | 5883044 |
JDBUILTHOMESLLC | BFR | P | 06/22/2018 | engineer letter for alternate hold downs at lower level slider on file / pictures of lateral bracing on file / still need to inspect corrections | LONNYS | LONNYS | | BFR | P | 5882327 |
JDBUILTHOMESLLC | BFR | P | 06/20/2018 | still missing STHD10 hold downs rear lower level slider / T01A missing lateral bracing upper level above garage / received engineering for 4 PLY LVL / received engineer letter for front entrance header / received correct truss packet for upper level above garage | LONNYS | LONNYS | | BFR | P | 5879633 |
JDBUILTHOMESLLC | BFR | R | 06/19/2018 | not dried in / need truss packet for trusses in bedroom over garage / strap balloon framed wall behind fireplace and pantry / missing VTCR clips on all V trusses / missing H2.5s at S02C above great room to deck / missing 3rd 2x10 header rear kitchen window / front entrance missing 3rd 2x12 header / missing 2nd H2.5 all S01 trusses over front entrance / pop out joist rear garage missing hardwear / need detail for 4 ply LVL at lower level / isolate post bottom of stairs / missing both STHD10 hold downs rear lower level slider | LONNYS | LONNYS | | BFR | R | 5878409 |
JDBUILTHOMESLLC | BSP | P | 05/30/2018 | panel splice not in middle 24" of garage narrow braced wall - missing LTSA24 straps interior garage narrow braced wall - can check both at frame / upper deck lid and posts OK / deck framing OK | LONNYS | LONNYS | | BSP | P | 5859425 |
JDBUILTHOMESLLC | BFI | C | 04/03/2018 | 2" R10 rigid OK at crawler perimeter | LONNYS | LONNYS | | BFI | C | 5806174 |
JDBUILTHOMESLLC | BFD | C | 04/03/2018 | drain is usable to sump pit - damp proofing OK | LONNYS | LONNYS | | BFD | C | 5806171 |
JDBUILTHOMESLLC | BFI | P | 04/03/2018 | still need to complete insulation inspection | LONNYS | LONNYS | | BFI | P | 5805752 |
JDBUILTHOMESLLC | BFD | P | 04/03/2018 | still need to perform drain inspection | LONNYS | LONNYS | | BFD | P | 5805750 |
JDBUILTHOMESLLC | BFN | C | 04/03/2018 | all paper work on file | LONNYS | LONNYS | | BFN | C | 5805747 |
JDBUILTHOMESLLC | BFT | C | 04/03/2018 | open hole on file - 2400 PSF - 5% - usable / soils on file / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified)
| LONNYS | LONNYS | | BFT | C | 5805744 |
JDBUILTHOMESLLC | BFD | P | 03/06/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5781273 |
JDBUILTHOMESLLC | BFT | P | 03/06/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5781272 |
JDBUILTHOMESLLC | BFN | P | 03/06/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5781271 |
ALL STAR ELECTRIC, INC. | E= | C | 10/30/2018 | no a/c | GARYL | GARYL | | E= | C | 6010987 |
ALL STAR ELECTRIC, INC. | E= | R | 10/25/2018 | Locked at 11:30 | GARYL | GARYL | | E= | R | 6005798 |
ALL STAR ELECTRIC, INC. | E= | T | 10/11/2018 | PAID (REC#1550284): Too many inspections, 1) closet light missing at front entry (?) switch is there, 2) 2-kitchen counter recepts not gfci, 3) need plates on switch/recept for dw/disp, 4) w/p recept off of living room not working, 5) gfci recept for jacuzzi not accessible NOTE! no a/c | GARYL | GARYL | | E= | T | 5992476 |
ALL STAR ELECTRIC, INC. | E= | R | 10/08/2018 | Not ready, called before I went to job site | GARYL | GARYL | | E= | R | 5989059 |
ALL STAR ELECTRIC, INC. | ES | C | 07/16/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter, new res. | JOHNN | JOHNN | | ES | C | 5903091 |
ALL STAR ELECTRIC, INC. | ES | R | 07/05/2018 | wrap GRC with corrosion resistant tape or spray. ok to upload pic | JOHNN | JOHNN | | ES | R | 5893818 |
ALL STAR ELECTRIC, INC. | ES | R | 06/26/2018 | large stack of sheet rock in front of panel, can not remove cover. | JOHNN | JOHNN | | ES | R | 5886098 |
ALL STAR ELECTRIC, INC. | ER | C | 06/18/2018 | Corrections complete / | ROB | ROB | | ER | C | 5877779 |
ALL STAR ELECTRIC, INC. | ER | R | 06/15/2018 | add mud ring for rev ufer access, lower bed rm: add outlet in 24" space, living rm: move outlet closer to railing, mount jet tub outlet box facing access panel,-------------------------#6cu, 14/3, no cv,rev ufer | JOHNN | JOHNN | | ER | R | 5876220 |
ALL STAR ELECTRIC, INC. | ER | R | 06/14/2018 | Not raedy / | ROB | ROB | | ER | R | 5874272 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 09/21/2018 | hi/lo transfer, line set coil rough | DAVIDH | DAVIDH | | H= | C | 5973230 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/27/2018 | GAS NEEDS CONNECTED TO WATER HEATER . NOTE HI/LO TRANSFER LINE SET AND COIL ONLY | DAVIDH | DAVIDH | | H= | P | 5946707 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 06/15/2018 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5876533 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 06/15/2018 | | DAVIDH | DAVIDH | | HRR | C | 5876527 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 06/14/2018 | INSULATION SHIELD ON F/P NEEDS ADDED TO ABOVE INSULATION LEVEL REST OK 6"OSA | DAVIDH | DAVIDH | | HRR | P | 5875106 |
L & L GAS SHOP, LLC. | HI | C | 06/05/2018 | 10 LB TEST OK | DAVIDH | DAVIDH | | HI | C | 5864939 |
L & L GAS SHOP, LLC. | HI | R | 06/04/2018 | LOW TEST- 6.5LBS. NOTE: 1 1/4" MAIN. 1 FURNACE, 1 WATER HEATER, 1 RANGE, 1 DRYER, 1 FIREPLACE, 1 BBQ | BILLS | BILLS | | HI | R | 5863453 |
JOLLY PLUMBING & HEATING INC. | P= | C | 09/19/2018 | Corrections made | SHANEN | SHANEN | | P= | C | 5970174 |
JOLLY PLUMBING & HEATING INC. | P= | P | 09/18/2018 | Loose shower arm at master shower, water off to lower level hall bath water closet, rest OK, PVB installed | SHANEN | SHANEN | | P= | P | 5968487 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 06/06/2018 | Corrections made, garage sink VTR | SHANEN | SHANEN | | PTO | C | 5866134 |
JOLLY PLUMBING & HEATING INC. | PTO | P | 05/30/2018 | need H/C hose bib in garage for sink, re- grade upstairs shower drain, can not tie upper garage sink into basement bathroom vent, need freeze protection in garage, can not have aav in fire rated garage wall, rest ok, finished basement, aav's at all lavs/ sinks and washer. | TAYLOR | TAYLOR | | PTO | P | 5859279 |
JOLLY PLUMBING & HEATING INC. | PB | C | 04/18/2018 | | TAYLOR | TAYLOR | | PB | C | 5819960 |