PALMER RIDGE CONSTRUCTION CO. | B= | C | 10/03/2018 | | BOBF | BOBF | | B= | C | 5985006 |
PALMER RIDGE CONSTRUCTION CO. | B= | P | 10/02/2018 | seal hole in garage ceiling / cable guards need to be tightened so as not to be allowed to spread greater than 4" -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 5983393 |
PALMER RIDGE CONSTRUCTION CO. | BIN | C | 06/28/2018 | | BOBF | BOBF | | BIN | C | 5888838 |
PALMER RIDGE CONSTRUCTION CO. | BFR | C | 06/19/2018 | | BOBF | BOBF | | BFR | C | 5879247 |
PALMER RIDGE CONSTRUCTION CO. | BLA | C | 06/19/2018 | | BOBF | BOBF | | BLA | C | 5879210 |
PALMER RIDGE CONSTRUCTION CO. | BSP | P | 06/11/2018 | Under deck insulation ok | TIMOTHYS | TIMOTHYS | | BSP | P | 5870268 |
PALMER RIDGE CONSTRUCTION CO. | BSP | P | 05/16/2018 | front porch with posts okay / training with Tim, reviewed porch framing requirements | BOBF | BOBF | | BSP | P | 5846498 |
PALMER RIDGE CONSTRUCTION CO. | BSP | P | 05/10/2018 | Garage portal walls okay / rear deck with posts okay / ST 22 straps per note A okay | BOBF | BOBF | | BSP | P | 5841802 |
PALMER RIDGE CONSTRUCTION CO. | BFI | C | 03/21/2018 | 24" R10 okay | SHAUN | SHAUN | | BFI | C | 5795125 |
PALMER RIDGE CONSTRUCTION CO. | BFD | C | 03/21/2018 | Drain around usable space / Drain to pit north west of usable space / Damp proofing okay | SHAUN | SHAUN | | BFD | C | 5795124 |
PALMER RIDGE CONSTRUCTION CO. | BFD | P | 03/21/2018 | soil report on file | BOBF | BOBF | | BFD | P | 5794490 |
PALMER RIDGE CONSTRUCTION CO. | BFT | C | 03/21/2018 | open hole 2400# and letter for footing steel and eufer on file | BOBF | BOBF | | BFT | C | 5794487 |
PALMER RIDGE CONSTRUCTION CO. | BFN | C | 03/21/2018 | design 2400# on file | BOBF | BOBF | | BFN | C | 5794486 |
PALMER RIDGE CONSTRUCTION CO. | BFT | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5782622 |
PALMER RIDGE CONSTRUCTION CO. | BFN | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5782621 |
TRUSTED ELECTRIC | E= | C | 09/26/2018 | 30 amp a/c , hot-tub prewire | TOMC | TOMC | | E= | C | 5977186 |
TRUSTED ELECTRIC | ES | C | 06/19/2018 | Residential Underground: 200 amp service new res. | BRET | BRET | | ES | C | 5879047 |
TRUSTED ELECTRIC | ES | R | 06/15/2018 | not ready | BRET | BRET | | ES | R | 5876745 |
TRUSTED ELECTRIC | ER | C | 06/15/2018 | 2-20 amp mcc in sub 1 spare 1 heat, #8cu to cook top and oven, vac installed low volt system | BRET | BRET | | ER | C | 5876740 |
TRUSTED ELECTRIC | EUG | C | 04/23/2018 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 5824621 |
TRUSTED ELECTRIC | EUG | R | 04/20/2018 | cable not in trench last 50' to home no marking tape , note 4/0-4/0-4/0 | BRET | BRET | | EUG | R | 5823366 |
CUSTOM CLIMATE CONTROL | H= | C | 10/01/2018 | NOTES: FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C COMPLETE X 2 | BENH | BENH | | H= | C | 5981410 |
CUSTOM CLIMATE CONTROL | H= | P | 09/26/2018 | VENT FOR WATER HEATER NEEDS TO BE B VENT PER MANUFACTURERS INSTRUCTION ON PAGE 12, ALSO NEEDS TO VENT VERTICALLY NOT HORIZONTALLY NOTES: FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C COMPLETE X 2 | BENH | BENH | | H= | P | 5977411 |
CUSTOM CLIMATE CONTROL | HC | C | 06/11/2018 | RELEASE METER | MATTM | MATTM | | HC | C | 5870969 |
CUSTOM CLIMATE CONTROL | HRR | C | 06/11/2018 | | MATTM | MATTM | | HRR | C | 5870967 |
CUSTOM CLIMATE CONTROL | HRR | R | 06/07/2018 | ON THE MAIN LEVEL, THE SOUTH FIREPLACE IS NOT FRAMED PER MANUFACTURES INSTALLATION INSTRUCTIONS ON PAGE 17 TABLE 10. TRIP FEE WAIVED, 4TH TRIP REQUIRED, TRIP FEE MAY BE APPLIED | MATTM | MATTM | | HRR | R | 5867557 |
CUSTOM CLIMATE CONTROL | HRR | P | 06/01/2018 | FIREPLACE FRAMING FRAMED IMPROPERLY, REST OK | BENH | BENH | | HRR | P | 5861541 |
COLORADO GAS SYSTEMS | HI | C | 06/01/2018 | | BENH | BENH | | HI | C | 5861540 |
COLORADO GAS SYSTEMS | HI | P | 05/31/2018 | PLEASE PROVIDE TOTAL BTU LOAD 10 LB TEST OK, 3/4" MAIN(MEDIUM PRESSURE) 2 FURNACE, 1 WATER HEATER, 3 FIREPLACE, 1 FUTURE OUTDOOR STUB | BENH | BENH | | HI | P | 5860466 |
CUSTOM CLIMATE CONTROL | HRR | P | 05/30/2018 | NEED WATER HEATER INSTALLED SO I CAN INSPECT VENTING, FIREPLACE FRAMING INCOMPLETE, ON BOTH MAIN LEVEL FIREPLACES NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C ROUGH COIL AND LINE SET X 2 | BENH | BENH | | HRR | P | 5858675 |
DBA PLUMBING LLC | P= | C | 09/25/2018 | | TAYLOR | TAYLOR | | P= | C | 5975904 |
DBA PLUMBING LLC | P= | P | 09/24/2018 | need drain downs for dog wash facet can submit photos, need RP mech rest ok note: potable water certification received and sent to scanning | JOSEPHD | JOSEPHD | | P= | P | 5974426 |
DBA PLUMBING LLC | PTO | C | 06/06/2018 | corrections made | JOSEPHD | JOSEPHD | | PTO | C | 5866033 |
DBA PLUMBING LLC | PTO | P | 06/05/2018 | need boca plates in multiple places in basement at bottom plates, rest ok note: finished basement, irrigation stub, mixing valve above hwh, running trap for dog wash at garage in basement, aav @ laundry tub veg sink, wet bar in mech room | JOSEPHD | JOSEPHD | | PTO | P | 5865191 |
PALMER RIDGE CONSTRUCTION CO. | PWO | C | 05/15/2018 | note: need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5845335 |
DBA PLUMBING LLC | PB | C | 04/04/2018 | | SHANEN | SHANEN | | PB | C | 5807259 |