ASPEN VIEW HOMES, LLC | B= | C | 07/31/2018 | Crawlspace / No AC | SHAUN | SHAUN | | B= | C | 5918948 |
ASPEN VIEW HOMES, LLC | BFR | P | 07/24/2018 | Engineer detail received for A1 truss repair - Contractor provided verification of truss repair on file | JUSTINL | JUSTINL | | BFR | P | 5911651 |
ASPEN VIEW HOMES, LLC | BIN | R | 05/30/2018 | Insulation OK pending frame | JUSTINL | JUSTINL | | BIN | R | 5859299 |
ASPEN VIEW HOMES, LLC | BFR | P | 05/30/2018 | At re-frame inspection broken web on A1 truss web 5-11 at great room observed - Request engineer detail for repair / Remove shingles from roof vent openings / Other frame corrections complete | JUSTINL | JUSTINL | | BFR | P | 5859297 |
ASPEN VIEW HOMES, LLC | BFR | R | 05/25/2018 | 1. Missing H2.5 at top cord of J4 in front room / 2. Missing B vent pipe jack / 3. Missing header at framed opening for upper window above entry door and at great room / 4. A35s not attached at mid point of A trusses per detail 10D1 at master / 5. Missing 2nd TBE at last A3 mid point bearing / Plans reviewed electronically / | JUSTINL | JUSTINL | | BFR | R | 5856364 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/03/2018 | wrong inspection | NATHAN | NATHAN | | BSP | P | 5835565 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/03/2018 | front porch, posts and garage portal frame okay | NATHAN | NATHAN | | BSP | P | 5835527 |
ASPEN VIEW HOMES, LLC | BFD | C | 04/06/2018 | Drain usable to sump pit / Damp proof OK | JUSTINL | JUSTINL | | BFD | C | 5810370 |
ASPEN VIEW HOMES, LLC | BFD | P | 04/06/2018 | Engineer observation for over ex drain on file - Drain tie in photo on file / Still need to inspect usable drain | JUSTINL | JUSTINL | | BFD | P | 5809680 |
ASPEN VIEW HOMES, LLC | BFN | C | 04/06/2018 | Engineer letter for foundation -- Eufer noted / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5809676 |
ASPEN VIEW HOMES, LLC | BFT | C | 04/06/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF ( Verified ) / Drain usable and over ex / 10% | JUSTINL | JUSTINL | | BFT | C | 5809674 |
ASPEN VIEW HOMES, LLC | BFT | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5782658 |
ASPEN VIEW HOMES, LLC | BFN | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5782657 |
PEAK ELECTRIC INC. | E= | C | 07/09/2018 | no a/c | TIMA | TIMA | | E= | C | 5896716 |
PEAK ELECTRIC INC. | ER | C | 05/22/2018 | | BRIAN | BRIAN | | ER | C | 5852563 |
PEAK ELECTRIC INC. | ES | C | 05/21/2018 | Residential Underground: 150 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5850616 |
PEAK ELECTRIC INC. | ER | R | 05/21/2018 | wire out of wall at ceiling by kitchen | TIMA | TIMA | | ER | R | 5850606 |
PEAK ELECTRIC INC. | EUG | C | 05/16/2018 | 2/0 | TIMA | TIMA | | EUG | C | 5846826 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/30/2018 | | KYLEW | KYLEW | | H= | C | 5917593 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/27/2018 | WATER HEATER CLOSET LACKS COMBUSTION AIR, DRYER VENT TERMINATION CANNOT HAVE A SCREEN, CRAWLSPACE SUPPLY REGISTER NEEDS DAMPER NOTES: 6" HIGH COMBUSTION AIR TO WATER HEATER CLOSET, CONDITIONED CRAWLSPACE (1 SUPPLY 1 RETURN, OUTSIDE AIR TO FURNACE RETURN, NO A/C | MATTM | MATTM | | H= | P | 5916579 |
MD SERVICE PLUMBING, INC. | HC | C | 05/24/2018 | RELEASE METER | RANDYB | RANDYB | | HC | C | 5854919 |
MD SERVICE PLUMBING, INC. | HI | C | 05/24/2018 | 10 LB Test okay. | RANDYB | RANDYB | | HI | C | 5854910 |
MD SERVICE PLUMBING, INC. | HI | P | 05/22/2018 | Lost test. 1" Main. 1 Furnace. 1 Water heater. 1 Range. | RANDYB | RANDYB | | HI | P | 5852468 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 05/21/2018 | NOTES: Conditioned crawlspace. Outside air to furnace return. No A/C. | RANDYB | RANDYB | | HRR | C | 5851456 |
MD SERVICE PLUMBING, INC. | P= | C | 07/27/2018 | | JOEL | JOEL | | P= | C | 5916934 |
MD SERVICE PLUMBING, INC. | P= | P | 07/11/2018 | no hot water, need freeze protection @ garage water htr closet, re inspect all. note: vtr and pvb ok | JOHNS | JOHNS | | P= | P | 5899152 |
MD SERVICE PLUMBING, INC. | PTO | C | 05/21/2018 | corrections made. note: access panel @ 3-part coupling | JOHNS | JOHNS | | PTO | C | 5851205 |
MD SERVICE PLUMBING, INC. | PTO | P | 05/17/2018 | low test @ mstr dwv gauge, need ready access to 3-part coupling, rest ok. note: by final need freeze pro @ garage water htr closet, crawl space, vtr (2), cwv @ right mstr, vtr @ left mstr, aav @ crawl space k.c. drain, irrigation stub, check 12x12 access panel @ 3-part coupling @ hallway behind water htr @ final | JOHNS | JOHNS | | PTO | P | 5848084 |
MD SERVICE PLUMBING, INC. | PB | C | 04/12/2018 | Test ok. | DANR | DANR | | PB | C | 5815603 |