ASPEN VIEW HOMES, LLC | B= | C | 07/26/2018 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 5915012 |
ASPEN VIEW HOMES, LLC | B= | P | 07/23/2018 | Crawl space / No deck / No AC. Additional Inspections Required (computer generated): External Agency Inspection UWS by WIDEFIELDWSD is not Completed yet (Contact: Wateropps@wwsdonline.com or 390-7111). | JUSTINL | JUSTINL | | B= | P | 5910963 |
ASPEN VIEW HOMES, LLC | BIN | C | 06/01/2018 | Insulation OK | JUSTINL | JUSTINL | | BIN | C | 5862146 |
ASPEN VIEW HOMES, LLC | BFR | C | 06/01/2018 | Frame corrections complete | JUSTINL | JUSTINL | | BFR | C | 5862145 |
ASPEN VIEW HOMES, LLC | BFR | P | 05/31/2018 | 1. Compromised studs in exterior bearing wall at laundry room / 2. Missing Strap per note A at master bath / 3. Add point loads in bearing wall at mech in great room and kitchen / Plans reviewed electronically / | JUSTINL | JUSTINL | | BFR | P | 5860741 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/03/2018 | front porch and posts okay, garage portal not needed. | NATHAN | NATHAN | | BSP | P | 5835535 |
ASPEN VIEW HOMES, LLC | BFD | C | 04/06/2018 | Drain usable to sump pit / Damp proof OK | JUSTINL | JUSTINL | | BFD | C | 5810356 |
ASPEN VIEW HOMES, LLC | BFD | P | 04/06/2018 | Engineer observation for over ex drain on file - Drain tie in photo on file / Need to inspect usable drain | JUSTINL | JUSTINL | | BFD | P | 5809662 |
ASPEN VIEW HOMES, LLC | BFN | C | 04/06/2018 | Engineer letter for foundation -- Eufer noted / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5809660 |
ASPEN VIEW HOMES, LLC | BFT | C | 04/06/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF ( Verified ) / Drain usable and over ex / 10% | JUSTINL | JUSTINL | | BFT | C | 5809659 |
ASPEN VIEW HOMES, LLC | BFT | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5782661 |
ASPEN VIEW HOMES, LLC | BFN | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5782660 |
PEAK ELECTRIC INC. | E= | C | 07/10/2018 | no a/c | TIMA | TIMA | | E= | C | 5898226 |
PEAK ELECTRIC INC. | E= | R | 07/06/2018 | correction not made on lights in crawl space | TIMA | TIMA | | E= | R | 5895508 |
PEAK ELECTRIC INC. | E= | R | 07/03/2018 | house gfci circuit no power,need guarded lights in crawl space | TIMA | TIMA | | E= | R | 5892520 |
PEAK ELECTRIC INC. | ES | C | 05/30/2018 | Residential Underground: 150 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5859302 |
PEAK ELECTRIC INC. | ER | C | 05/30/2018 | #8 AL to oven/range / No Cent Vac / | TIMA | TIMA | | ER | C | 5859278 |
PEAK ELECTRIC INC. | EUG | C | 05/16/2018 | 2/0 | TIMA | TIMA | | EUG | C | 5846825 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/17/2018 | RECEIVED IMAGES OF CORRECTION FROM CONTRACTOR, SEE IMAGES. | MATTM | MATTM | | H= | C | 5905498 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/17/2018 | CRAWLSPACE SUPPLY NEEDS DAMPER, PLEASE ATTACH PICTURE OF CORRECTION TO NEXT INSPECTION REQUEST OR EMAIL TO MATTM@PPRBD.ORG NOTES: CONDITIONED CRAWLSPACE (1 SUPPLY 1 RETURN), OUTSIDE AIR TO FURNACE RETURN, NO A/C, LOUVER DOOR TO WATER HEATER CLOSET | MATTM | MATTM | | H= | P | 5904927 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 05/30/2018 | RELEASE METER | RANDYB | RANDYB | | HC | C | 5859473 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 05/30/2018 | NOTES: Conditioned crawlspace. Outside air to furnace return. No A/C. | RANDYB | RANDYB | | HRR | C | 5859466 |
MD SERVICE PLUMBING, INC. | HI | C | 05/15/2018 | NOTES: 10 LB TEST IS OK. 1" MAIN FOR 1 - FURNACE AND 1 - WATER HEATER. | JEFFB | JEFFB | | HI | C | 5845337 |
MD SERVICE PLUMBING, INC. | P= | C | 07/05/2018 | corrections made, see images | JOHNS | JOHNS | | P= | C | 5893314 |
MD SERVICE PLUMBING, INC. | P= | P | 07/03/2018 | need clearance from combustibles @ water htr vent connector @ 1" cold pex, can complete w/ uploaded image w/ tape measure in pic showing 1" clearance, rest ok. note: pvb ok, conditioned crawl space | JOHNS | JOHNS | | P= | P | 5892642 |
MD SERVICE PLUMBING, INC. | PTO | C | 05/23/2018 | note: crawl space, vtr (2), cwv @ pwdr lav, aav @ right mstr, cwv @ left mstr, aav @ crawl space k.c. drain, irrigation stub | JOHNS | JOHNS | | PTO | C | 5853604 |
MD SERVICE PLUMBING, INC. | PB | C | 04/12/2018 | Test ok. | DANR | DANR | | PB | C | 5815605 |