ASPEN VIEW HOMES, LLC | B= | C | 07/16/2018 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 5904168 |
ASPEN VIEW HOMES, LLC | B= | P | 07/10/2018 | AC unit set after mech final complete - Will need separate permit // Crawl space / No deck. Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: Paul Wiggs at 520-6819), External Agency Inspection UWS by WIDEFIELDWSD is not Completed yet (Contact: Wateropps@wwsdonline.com or 390-7111). | JUSTINL | JUSTINL | | B= | P | 5898348 |
ASPEN VIEW HOMES, LLC | BIN | C | 05/24/2018 | Insulation OK | JUSTINL | JUSTINL | | BIN | C | 5855396 |
ASPEN VIEW HOMES, LLC | BFR | C | 05/24/2018 | Engineer letter received for narrow braced wall hold downs - Other frame corrections complete | JUSTINL | JUSTINL | | BFR | C | 5855387 |
ASPEN VIEW HOMES, LLC | BFR | P | 05/22/2018 | Portal wall hold downs call for STHD14 where STHD10's are installed / Missing TBE on T04G back of garage / Missing TBE's center bearing wall / ST12 each side of front door | SHAUN | SHAUN | | BFR | P | 5852131 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/07/2018 | Front porch OK / plans reviewed onsite | RICHB | RICHB | | BSP | P | 5837242 |
ASPEN VIEW HOMES, LLC | BFD | C | 04/13/2018 | Damp proofing okay. | NOAH | NOAH | | BFD | C | 5816972 |
ASPEN VIEW HOMES, LLC | BFD | P | 04/13/2018 | BFD observation received / will follow-up to verify damp proofing | RICHB | RICHB | | BFD | P | 5816079 |
ASPEN VIEW HOMES, LLC | BFT | C | 04/13/2018 | Open hole on file | RICHB | RICHB | | BFT | C | 5816077 |
ASPEN VIEW HOMES, LLC | BFN | C | 04/13/2018 | Open hole received - 2000 psf, model 1398.3, drain (habitable), float 1.5", 10% grading // drain observation received | RICHB | RICHB | | BFN | C | 5816076 |
ASPEN VIEW HOMES, LLC | BFT | P | 04/13/2018 | Footing & foundation observation received - ufer noted / foundation design received - 2000 psf, model number verified | RICHB | RICHB | | BFT | P | 5816072 |
ASPEN VIEW HOMES, LLC | BFT | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5782665 |
ASPEN VIEW HOMES, LLC | BFN | P | 03/07/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5782664 |
PEAK ELECTRIC INC. | E= | C | 07/05/2018 | a/c installed--20 amp | TIMA | TIMA | | E= | C | 5894253 |
PEAK ELECTRIC INC. | E= | R | 07/03/2018 | secure front exterior recept., need guarded light in crawl space | TIMA | TIMA | | E= | R | 5892469 |
PEAK ELECTRIC INC. | ES | C | 05/31/2018 | Residential Underground: 150 amp 3/w new res. needs meter seal | TIMA | TIMA | | ES | C | 5860334 |
PEAK ELECTRIC INC. | EUG | C | 05/31/2018 | | TIMA | TIMA | | EUG | C | 5860333 |
PEAK ELECTRIC INC. | ER | C | 05/18/2018 | #8 AL to oven/range / Irreversible UFER connection / No Cent Vac / | TIMA | TIMA | | ER | C | 5849641 |
PEAK ELECTRIC INC. | ER | R | 05/16/2018 | damaged wire at bath light box | TIMA | TIMA | | ER | R | 5846810 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/09/2018 | SPOKE WITH CONTRACTOR ON 7/6/18. CONTRACTOR SAID CONDENSATE OUTLET IS DAISY CHAINED TO GFI ELSEWHERE. | MATTM | MATTM | | H= | C | 5895934 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 07/06/2018 | CONDENSATE PUMP STILL NOT PLUGGED INTO GFI, 4TH TRIP REQUIRED, TRIP FEES MAY BE APPLIED | MATTM | MATTM | | H= | R | 5894903 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 07/05/2018 | CONDENSATE PUMP NEEDS TO BE PLUGGED INTO GFI, SUPPLY IN CRAWLSPACE NEEDS TO HAVE DAMPER MECHANICALLY FASTENED IN THE OPEN POSITION, OK TO ATTACH PICTURES TO NEXT INSPECTION REQUEST | MATTM | MATTM | | H= | R | 5894055 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | L | 07/03/2018 | HOUSE LOCKED | MATTM | MATTM | | H= | L | 5893242 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 06/26/2018 | crawlspace needs to be condintioned. furnace change letter received. notes: 6" high combustion air to water heater closet, outside air to return, conditioned crawlspace, a/c rough line set only. | KYLEW | KYLEW | | H= | P | 5885869 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 05/16/2018 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5846737 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 05/16/2018 | NEED ALL EQUIPMENT SPECS AT THE FINAL. NOTES: OUTSIDE AIR TO THE RETURN DUCT. | JEFFB | JEFFB | | HRR | C | 5846730 |
MD SERVICE PLUMBING, INC. | HI | C | 05/15/2018 | NOTES: 10 LB TEST IS OK. 1" MAIN FOR THE FURNACE AND WATER HEATER. | JEFFB | JEFFB | | HI | C | 5845280 |
MD SERVICE PLUMBING, INC. | P= | C | 07/03/2018 | corrections made, see images | JOHNS | JOHNS | | P= | C | 5892071 |
MD SERVICE PLUMBING, INC. | P= | P | 06/27/2018 | need to consult w/ senior about garage water htr closet freeze protection, will update notes in morning, rest ok. note: pvb ok, aav @ crawl space k.c. drain, conditioned crawl space
updated notes 6/28/18 as follows- need freeze protection for water htr closet- | JOHNS | JOHNS | | P= | P | 5887077 |
MD SERVICE PLUMBING, INC. | PTO | C | 05/11/2018 | by final need heat run @ water htr for freeze pro, need k.c. drain and vent @ crawl space by final, rest ok. note: crawl space, vtr (3), irrigation stub, by final need heat run @ water htr for freeze pro, be mindful of freeze pro @ crawl space by final, need k.c. drain and vent @ crawl space by final | JOHNS | JOHNS | | PTO | C | 5842312 |
MD SERVICE PLUMBING, INC. | PB | C | 04/18/2018 | Test ok. | DANR | DANR | | PB | C | 5820453 |