SNIDER CUSTOM HOMES | B= | C | 09/17/2018 | IECC certificate on file - Engineers observation for porch piers on file | TIMOTHYS | TIMOTHYS | | B= | C | 5966414 |
SNIDER CUSTOM HOMES | B= | P | 09/13/2018 | Need 3rd party IECC certificate - Need 3rd party pier observations for front porch - Front porch posts ok - Covered rear patio - Unfinished basement - AC installed -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): Plumbing Final Inspection is not Completed yet. | TIMOTHYS | TIMOTHYS | | B= | P | 5964379 |
SNIDER CUSTOM HOMES | BLA | C | 08/10/2018 | Lath ok | TIMOTHYS | TIMOTHYS | | BLA | C | 5930252 |
SNIDER CUSTOM HOMES | BFR | C | 06/04/2018 | corrections complete -- call porch post connections and piers on BSP | SCOTTS | SCOTTS | | BFR | C | 5863260 |
SNIDER CUSTOM HOMES | BFR | P | 06/01/2018 | Truss repair letters on file / Narrow wall missing 3" nailing, Panel splice within 24" of center wall and 1,000 lbs straps / ST22 missing NW corner / Porch lids okay, No pier inspection at this time / Glue shims / Hangers and LS30's needed at landing | SHAUN | SHAUN | | BFR | P | 5862624 |
SNIDER CUSTOM HOMES | BIN | P | 06/01/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | TERRI | TERRI | | BIN | P | 5861374 |
SNIDER CUSTOM HOMES | BFD | C | 04/02/2018 | corrections complete | SCOTTS | SCOTTS | | BFD | C | 5804978 |
SNIDER CUSTOM HOMES | BFD | P | 03/30/2018 | Complete damp proofing as noted in previous inspection / Complete drain around usable space per soils report | SHAUN | SHAUN | | BFD | P | 5804244 |
SNIDER CUSTOM HOMES | BFN | C | 03/30/2018 | Received Soils report, Open hole report, / 1,000 psf / Drain habitable / Float and Isolate / 5 % grade / drain design / Foundation design 1,000 psf / Footing and foundation observations with eufer noted | SHAUN | SHAUN | | BFN | C | 5804237 |
SNIDER CUSTOM HOMES | BFT | C | 03/30/2018 | Received Soils report, Open hole report, / 1,000 psf / Drain habitable / Float and Isolate / 5 % grade / drain design / Foundation design 1,000 psf / Footing and foundation observations with eufer noted | SHAUN | SHAUN | | BFT | C | 5804235 |
SNIDER CUSTOM HOMES | BFD | R | 03/29/2018 | provide soils/open ex -- missing damp proofing several areas per IRC 406.2 -- missing section rock and fabric at utility stub | SCOTTS | SCOTTS | | BFD | R | 5802425 |
ROWAN ELECTRIC LLC | E= | C | 09/11/2018 |
| JOSEPH | JOSEPH | | E= | C | 5960873 |
ROWAN ELECTRIC LLC | E= | R | 09/07/2018 | Missing AFCI protection at service & sub panel. (Dishwasher/disposal) ---- Cage open bulbs in crawler. ------- Furnace disconnect need to have factory on/off can't use a rocker switch. ------ Well disconnect ground screw loose. ---- Missing ISBT ----- At the AC disconnect on the line side restrip & reterminate because your conductor strands are badly score on line side. ----- Back side coach lights need backing (Too big an opening to fill with silicone). --- Notes: 30 amp ac & PVC from home to future post light. | JOSEPH | JOSEPH | | E= | R | 5958469 |
ROWAN ELECTRIC LLC | E= | R | 09/06/2018 | Not ready --- Complete reinspection | JOSEPH | JOSEPH | | E= | R | 5956653 |
ROWAN ELECTRIC LLC | ES | C | 07/19/2018 | Residential Underground: 200 amp sub panel is fed off of 200 amp service at out-building. | JOSEPH | JOSEPH | | ES | C | 5907819 |
ROWAN ELECTRIC LLC | EP | C | 05/25/2018 | 200 amp sub panel at home good. UFER is ir. Notes: Unable to request meter set until pedestal is set. | JOSEPH | JOSEPH | | EP | C | 5856229 |
ROWAN ELECTRIC LLC | EUG | C | 05/24/2018 | 3w URD from location of future pedestal to detached garage & 4 w URD from garage to home. | JOSEPH | JOSEPH | | EUG | C | 5854594 |
ROWAN ELECTRIC LLC | EP | R | 05/24/2018 | UFER at home is not connected. ------ When you recall the service call in accessory building too since the home is sub fed of the detached garage. ------------ No utility pedestal set at this time. | JOSEPH | JOSEPH | | EP | R | 5854591 |
ROWAN ELECTRIC LLC | ER | C | 05/24/2018 | Unfinished basement ------------ Floated sub fed w/2224 ser ------------ 2 -6/3 al --------- 2 - 10/3 ----- No vac ----------- Notes: UFER not connected at this time & house panel is fed off of detached garage panel. | JOSEPH | JOSEPH | | ER | C | 5854585 |
GOSSAGE CONSTRUCTION | H= | C | 09/13/2018 | NOTE: CONDITIONED CRAWLSPACE, UNFINISHED BASEMENT, DIRECT VENT FURNACE, FULL A/C, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | H= | C | 5963587 |
GOSSAGE CONSTRUCTION | H= | P | 09/12/2018 | COIL CHANGE LETTER RECEIVED, SEE IMAGES | BILLS | BILLS | | H= | P | 5962151 |
GOSSAGE CONSTRUCTION | HSP | C | 09/12/2018 | COIL PERFORMANCE DATA | BILLS | BILLS | | HSP | C | 5962150 |
GOSSAGE CONSTRUCTION | H= | P | 09/11/2018 | NEED WATER HEATER INSTALLATION INSTRUCTIONS ON SITE TO CONFIRM IF SCREEN AT TERMINATION IS REQUIRED OR ACCEPTED. NEED COIL CHANGE LETTER ATTACHED. Form can be found on the PPRBD website under Downloads, Residential Handouts, Equipment Change Residential Duct Design. / | BILLS | BILLS | | H= | P | 5961062 |
GOSSAGE CONSTRUCTION | H= | P | 09/05/2018 | NEED TO COMPLETE WATER HEATER TERMINATION PER INSTALLATION INSTRUCTIONS / INSTALLATION DOES NOT SHOW A SCREEN IS REQUIRED , IF SCREEN IS USED AT TERMINATION CONTRACTOR MUST SHOW WHERE IN THE INSTALLATION INSTRUCTION THAT IT IS REQUIRED . NEED EQUIPMENT CHANGE LETTER FOR COIL . OK TO ATTACH PICTURES TO NEXT INSPECTION REQUEST. NOTE: OUTSIDE AIR TO FURNACE RETURN, A/C , DIRECT VENT FURNACE, NON DIRECT VENT WATER HEATER , UNFINISHED BASEMENT, CONDITIONED CRAWLSPACE. | LIDO | LIDO | | H= | P | 5956185 |
GOSSAGE CONSTRUCTION | HC | C | 05/30/2018 | RELEASE METER | MATTM | MATTM | | HC | C | 5859057 |
GOSSAGE CONSTRUCTION | HRR | C | 05/30/2018 | | MATTM | MATTM | | HRR | C | 5859056 |
GOSSAGE CONSTRUCTION | HRR | R | 05/29/2018 | NO CORRECTIONS MADE. FIREPLACE VENT STILL NEEDS 1" CLEARANCE FROM ROOFING MATERIAL , INSULATION SHIELD FOR FIREPLACE VENT NEEDS TO MAINTAIN 1" CLEARANCE FROM VENT | MATTM | MATTM | | HRR | R | 5857229 |
GOSSAGE CONSTRUCTION | HRR | P | 05/25/2018 | FIREPLACE VENT NEEDS 1" CLEARANCE FROM ROOFING MATERIAL. INSULATION SHIELD FOR FIREPLACE VENT NEEDS TO MAINTAIN 1" CLEARANCE FROM VENT. PERFORMANCE TEST BY FINAL. CHANGE OF EQUIPMENT LETTER FOR COIL BY FINAL. NOTE: OUTSIDE AIR TO FURNACE RETURN, A/C ROUGH COIL AND LINE SET ONLY, DIRECT VENT FURNACE, UNFINISHED BASEMENT, CONDITIONED CRAWLSPACE. | DUSTINS | DUSTINS | | HRR | P | 5856153 |
NASRALLAH PLUMBING & HEATING, INC. | HO | C | 05/24/2018 | 10LB TEST OK, 140' OF 1/2" POLY PIPE WITH TRACER WIRE FROM TANK TO REGULATOR AT HOUSE | BILLS | BILLS | | HO | C | 5854771 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 05/17/2018 | 10LB TEST OK, 1 FURNACE, 1 WATER HEATER, 1 FIREPLACE, 1 BBQ | BILLS | BILLS | | HI | C | 5847626 |
B & L PLUMBING, INC. | P= | C | 09/17/2018 | potable water certification sent to scanning | JOSEPHD | JOSEPHD | | P= | C | 5966403 |
B & L PLUMBING, INC. | P= | P | 09/07/2018 | need potable water certification, rest ok note: unfinished basement, no irrigation | JOSEPHD | JOSEPHD | | P= | P | 5958209 |
B & L PLUMBING, INC. | PWO | C | 07/20/2018 | correction made | JOSEPHD | JOSEPHD | | PWO | C | 5909643 |
HOMEOWNER | PWO | P | 06/11/2018 | pipe not deep enough under window well need 46" from dirt at bottom to pipe note: need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | P | 5871017 |
B & L PLUMBING, INC. | PTO | C | 05/15/2018 | unfinished basement, tempering valve at water heater, sprinkler stub capped at main, will check pressure tank connections at final, (still need outside under ground water line from well to house inspection-pwo) | TED | TED | | PTO | C | 5845861 |
B & L PLUMBING, INC. | PB | C | 04/09/2018 | | JOSEPHD | JOSEPHD | | PB | C | 5811564 |