ROCKWOOD HOMES, LLC | B= | C | 09/24/2018 | corrections okay | BRIANB | BRIANB | | B= | C | 5974595 |
ROCKWOOD HOMES, LLC | B= | C | 09/21/2018 | correction complete | SCOTTS | SCOTTS | | B= | C | 5976475 |
ROCKWOOD HOMES, LLC | B= | P | 09/20/2018 | master bedroom egress window sill over 44" -- finished basement/rear deck with cover -- Schedule a new Building Final when above items are complete. | SCOTTS | SCOTTS | | B= | P | 5971374 |
ROCKWOOD HOMES, LLC | BSP | P | 09/10/2018 | deck framing ok/reviewed plot plan | SCOTTS | SCOTTS | | BSP | P | 5960042 |
ROCKWOOD HOMES, LLC | BSP | P | 09/07/2018 | ADDITIONAL PLAN REVIEW TIME: (No Fee) From: BECKYA Splice was submitted as L39062 but is now under L39061 | BECKYA | BECKYA | | BSP | P | 5958938 |
ROCKWOOD HOMES, LLC | BSP | R | 09/07/2018 | inspection cancelled onsite by GC / no deck inspection performed | BRIANB | BRIANB | | BSP | R | 5958628 |
ROCKWOOD HOMES, LLC | BIN | C | 08/09/2018 | finished basement / no deck installed | BRIANB | BRIANB | | BIN | C | 5929640 |
ROCKWOOD HOMES, LLC | BFR | C | 08/09/2018 | corrections okay / letter for truss repairs received onsite | BRIANB | BRIANB | | BFR | C | 5929635 |
ROCKWOOD HOMES, LLC | BFR | R | 08/09/2018 | correction to previous BFR/entered on 6532 -- missing garage door/not dried in -- HUS28 require 3 1/2" 16d per manufacturer specs -- complete foam and firestop -- fireblock tub -- missing spikes on floating walls in front bedroom closet -- provide truss fixes for B05's and B07 | SCOTTS | SCOTTS | | BFR | R | 5929621 |
ROCKWOOD HOMES, LLC | BFR | P | 08/03/2018 | repair interior layer of party wall in garage and kitchen -- nails on HUS26 not per manufacturer specs -- A15's along A05 more than 1/8" away from face -- provide letter for top chord of joist notched out and joist cut out above bedroom and bathroom -- ok to insulate provided corrections can be viewed | SCOTTS | SCOTTS | | BFR | P | 5923458 |
ROCKWOOD HOMES, LLC | BFD | C | 08/03/2018 | soils report/open ex/footing and foundation observations/drain observation on file | SCOTTS | SCOTTS | | BFD | C | 5923448 |
ROCKWOOD HOMES, LLC | BFN | C | 08/03/2018 | | SCOTTS | SCOTTS | | BFN | C | 5923447 |
ROCKWOOD HOMES, LLC | BFT | C | 08/03/2018 | | SCOTTS | SCOTTS | | BFT | C | 5923445 |
ROCKWOOD HOMES, LLC | BSP | P | 08/02/2018 | drain connection to street complete - photo on file / still need all paper work to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5921464 |
ROCKWOOD HOMES, LLC | BLA | P | 07/11/2018 | bathroom window installed backwards/weep holes inside -- rest of lath ok | SCOTTS | SCOTTS | | BLA | P | 5899807 |
ROCKWOOD HOMES, LLC | BLA | R | 07/10/2018 | cancelled onsite by GC / no inspection performed | BRIANB | BRIANB | | BLA | R | 5898008 |
ROCKWOOD HOMES, LLC | BSP | P | 06/06/2018 | front and rear porch lid and posts okay / drag strut at garage okay / note - need to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5866705 |
ROCKWOOD HOMES, LLC | BSP | R | 06/06/2018 | duplicate porch inspection requested | BRIANB | BRIANB | | BSP | R | 5866689 |
ROCKWOOD HOMES, LLC | BSP | P | 05/25/2018 | verified 5/8" x gyp at interior side of trusses | BRIANB | BRIANB | | BSP | P | 5855985 |
ROCKWOOD HOMES, LLC | BSP | P | 05/24/2018 | 5/8" type x gyp at inside of unit separation wall okay only / verify gyp at main floor rim at frame inspection / still need to inspect gyp at trusses / note - need to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5854632 |
ROCKWOOD HOMES, LLC | BFD | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5788241 |
ROCKWOOD HOMES, LLC | BFT | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5788240 |
ROCKWOOD HOMES, LLC | BFN | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5788239 |
MEYER ELECTRIC | E= | C | 09/17/2018 | Correction complete / | ROB | ROB | | E= | C | 5967026 |
MEYER ELECTRIC | E= | R | 09/14/2018 | Lower NE bed closet light doesn't have proper clearance from shelf / 25 amp AC Installed / | ROB | ROB | | E= | R | 5965787 |
MEYER ELECTRIC | E= | R | 09/13/2018 | Not ready / | ROB | ROB | | E= | R | 5964225 |
MEYER ELECTRIC | ES | C | 07/25/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 5913456 |
MEYER ELECTRIC | ER | C | 07/25/2018 | 2 - #6 , 2 - #10 , irreversible ufer , no mcc , no central vac , finished basement | TOMC | TOMC | | ER | C | 5913455 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 09/10/2018 | Furnace vent needs secured flush to furnace with 3 fasteners. Performance test still needed. Notes-- Unfinished basement. Outside air to return. AC complete. | JEFFL | JEFFL | | H= | C | 5960533 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/01/2018 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5920394 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/01/2018 | THE PERFORMANCE TEST IS REQUIRED AT THE FINAL. NOTES: ALL ITEMS HAVE BEEN CORRECTED. | JEFFB | JEFFB | | HRR | C | 5920379 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 07/31/2018 | NEED MAKE UP AIR FOR LAUNDRY. SUPPORT B VENT MAIN LEVEL. INSTALL SUPPLY IN WEST BASEMENT BEDROOM. SUPPORT OUTSIDE AIR IN BASEMENTJOIST BAY. B VENT MUST MAINTAIN MINIMUM 1" CLEARANCE TO FRAMING IN BASEMENT. LINE SET NEEDS TO BE ISOLATED FROM ALL DISSIMILAR METAL STAPS. INSTALL 3 SCREWS IN ALL JOINTS IN BASEMENT BATHROOM SUPPLY. BY FINAL NEED PERFORMANCE TEST PER PG 22 IN BLUEBEAM. NOTES:FINISHED BASEMENT, OUTSIDE AIR TO RETURN, A/C ROUGH COIL AND LINE SET. | KYLEW | KYLEW | | HRR | P | 5919900 |
CORNERSTONE PLUMBING INC | HI | C | 07/25/2018 | NOTES: 10 LB TEST IS OK. 1" MAIN FOR 1 - FURNACE, 1 - WATER HEATER, 1 - RANGE, AND 1 - FIREPLACE. | JEFFB | JEFFB | | HI | C | 5912973 |
CORNERSTONE PLUMBING INC | P= | C | 09/12/2018 | ?finished basement | TED | TED | | P= | C | 5962975 |
CORNERSTONE PLUMBING INC | PTO | C | 07/13/2018 | finished basement, aav basement lav, no sprinkler stub | TED | TED | | PTO | C | 5901958 |
CORNERSTONE PLUMBING INC | PB | C | 05/09/2018 | ok, water under footer | TED | TED | | PB | C | 5839955 |
CORNERSTONE PLUMBING INC | PB | P | 05/08/2018 | post address, low test, re inspect all | JOHNS | JOHNS | | PB | P | 5839272 |