ROCKWOOD HOMES, LLC | B= | C | 09/21/2018 | finished basement/no deck | SCOTTS | SCOTTS | | B= | C | 5973500 |
ROCKWOOD HOMES, LLC | BSP | T | 08/31/2018 | PAID (REC#1532811) ADDITIONAL PLAN REVIEW TIME: $50 From: BPHILLIPS Add door between hall and family room. | BPHILLIPS | BPHILLIPS | | BSP | T | 5952102 |
ROCKWOOD HOMES, LLC | BSP | P | 08/27/2018 | ADDITIONAL PLAN REVIEW TIME: (No Fee) From: BECKYA Added Deck | BECKYA | BECKYA | | BSP | P | 5946742 |
ROCKWOOD HOMES, LLC | BIN | C | 08/13/2018 | frame inspection complete | BRIANB | BRIANB | | BIN | C | 5931823 |
ROCKWOOD HOMES, LLC | BFR | C | 08/13/2018 | corrections okay / letter for cut floor joist received onsite | BRIANB | BRIANB | | BFR | C | 5931822 |
ROCKWOOD HOMES, LLC | BIN | R | 08/10/2018 | insulation okay / need to complete frame inspection | BRIANB | BRIANB | | BIN | R | 5930974 |
ROCKWOOD HOMES, LLC | BFR | P | 08/10/2018 | repairs for cut floor joist over basement bedroom and bath are incomplete - still need to pick up engineering letter for repairs / other corrections okay | BRIANB | BRIANB | | BFR | P | 5930966 |
ROCKWOOD HOMES, LLC | BFR | P | 08/09/2018 | correction to previous BFR/entered on 6548 -- repair interior layer of party wall in garage and kitchen -- nails on HUS26 not per manufacturer specs -- A15's along A05 more than 1/8" away from face -- provide letter for top chord of joist notched out and joist cut out above bedroom and bathroom -- ok to insulate provided corrections can be viewed | SCOTTS | SCOTTS | | BFR | P | 5929630 |
ROCKWOOD HOMES, LLC | BFR | R | 08/03/2018 | missing garage door/not dried in -- HUS28 require 3 1/2" 16d per manufacturer specs -- complete foam and firestop -- fireblock tub -- missing spikes on floating walls in front bedroom closet -- provide truss fixes for B05's and B07 | SCOTTS | SCOTTS | | BFR | R | 5923444 |
ROCKWOOD HOMES, LLC | BFD | C | 08/03/2018 | soils report/open ex/footing and foundation observations/drain observation on file | SCOTTS | SCOTTS | | BFD | C | 5923436 |
ROCKWOOD HOMES, LLC | BFN | C | 08/03/2018 | | SCOTTS | SCOTTS | | BFN | C | 5923435 |
ROCKWOOD HOMES, LLC | BFT | C | 08/03/2018 | | SCOTTS | SCOTTS | | BFT | C | 5923430 |
ROCKWOOD HOMES, LLC | BSP | P | 08/02/2018 | drain connection to street complete - photo on file / still need all paper work to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5921481 |
ROCKWOOD HOMES, LLC | BSP | R | 08/02/2018 | photo of sprinkler line at driveway not required for inspections | BRIANB | BRIANB | | BSP | R | 5921427 |
ROCKWOOD HOMES, LLC | BLA | C | 07/11/2018 | lath ok | SCOTTS | SCOTTS | | BLA | C | 5899814 |
ROCKWOOD HOMES, LLC | BLA | R | 07/10/2018 | cancelled onsite by GC | BRIANB | BRIANB | | BLA | R | 5897995 |
ROCKWOOD HOMES, LLC | BSP | P | 06/06/2018 | front and rear porch lid and posts okay / drag strut at garage okay / note - need to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5866711 |
ROCKWOOD HOMES, LLC | BSP | P | 05/25/2018 | verified 5/8" x gyp at interior side of trusses | BRIANB | BRIANB | | BSP | P | 5855982 |
ROCKWOOD HOMES, LLC | BSP | P | 05/24/2018 | 5/8" type x gyp at inside of unit separation wall okay only / verify gyp at main floor rim at frame inspection / still need to inspect gyp at trusses / note - need to complete foundation inspections | BRIANB | BRIANB | | BSP | P | 5854644 |
ROCKWOOD HOMES, LLC | BFD | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5788247 |
ROCKWOOD HOMES, LLC | BFT | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5788246 |
ROCKWOOD HOMES, LLC | BFN | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5788245 |
MEYER ELECTRIC | E= | C | 09/18/2018 | Correction complete / | ROB | ROB | | E= | C | 5968219 |
MEYER ELECTRIC | E= | R | 09/17/2018 | Need recpt. for HWH circulator pump / 25 amp AC installed / | ROB | ROB | | E= | R | 5967018 |
MEYER ELECTRIC | E= | R | 09/14/2018 | Still not ready / | ROB | ROB | | E= | R | 5965802 |
MEYER ELECTRIC | E= | R | 09/13/2018 | Not ready / | ROB | ROB | | E= | R | 5964212 |
MEYER ELECTRIC | ES | C | 07/23/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 5910952 |
MEYER ELECTRIC | ER | C | 07/20/2018 | need to have the service ready at the rough to avoid three trips out here or a trip fee will have to be assessed --- sub panel in the basement OK , no multi no central vac --- finished basement | CRAIGS | CRAIGS | | ER | C | 5909331 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 09/20/2018 | | JEFFL | JEFFL | | H= | C | 5971552 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 09/20/2018 | Performance test still needed. | JEFFL | JEFFL | | H= | P | 5971450 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 09/10/2018 | Furnace vent needs secured flush to furnace with 3 fasteners. Performance test still needed. Notes-- Finished basement. Outside air to return. AC complete. Louver door to mechanical room. | JEFFL | JEFFL | | H= | P | 5960531 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/01/2018 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5920424 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/01/2018 | | JEFFB | JEFFB | | HRR | C | 5920331 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 07/31/2018 | SUPPORT DRYER VENT IN ATTIC. INSTALL MAKE UP AIR FOR LAUNDRY ROOM. SEAL 4" FOR THE LAUNDRY ROOM AT THE BOOT IN THE BASEMENT. BY FINAL: NEED PERFORMANCE TEST AS NOTED ON PAGE 22 OF BLUE BEAM. NOTES: FINISHED BASEMENT, OUTSIDE AIR TO RETURN, A/C ROUGH LINE SET AND COIL. | KYLEW | KYLEW | | HRR | P | 5919945 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 07/27/2018 | STOPPED INSPECTION. NOT READY. SEVERAL UNSEALED SUPPLIES. DRYER VENT NOT SUPPORTED. FIREPLACE IS INCOMPLETE. HOLES IN THE B VENT MAIN LEVEL. INCOMPLETE BASEMENT BATH FAN. LOOSE DUCT STRAPS. MORE?? CONTRACTOR TO WALK JOB BEFOR CALLING NEXT INSPECTION. | KYLEW | KYLEW | | HRR | R | 5916748 |
CORNERSTONE PLUMBING INC | HI | C | 07/24/2018 | 10 LB TEST OK. 1" MAIN, 1 FURNACE, 1 WATER HEATER, 1 RANGE, 1 FIREPLACE. | KYLEW | KYLEW | | HI | C | 5912769 |
CORNERSTONE PLUMBING INC | P= | C | 09/19/2018 | correction made | TED | TED | | P= | C | 5969789 |
CORNERSTONE PLUMBING INC | P= | P | 09/13/2018 | still need recirc power outlet, can complete w/ uploaded image, rest ok | JOHNS | JOHNS | | P= | P | 5963716 |
CORNERSTONE PLUMBING INC | P= | R | 09/12/2018 | complete basement bathroom trim, need electric outlet for curc. pump note: finished basement | TED | TED | | P= | R | 5962972 |
CORNERSTONE PLUMBING INC | PTO | C | 07/12/2018 | finished basement, bar sink rough in wall (aav if completed ), no sprinkler stub | TED | TED | | PTO | C | 5900722 |
CORNERSTONE PLUMBING INC | PB | C | 05/09/2018 | ok, water under footer | TED | TED | | PB | C | 5839952 |
CORNERSTONE PLUMBING INC | PB | P | 05/08/2018 | post address, low test, re inspect all | JOHNS | JOHNS | | PB | P | 5839267 |