TUSCANY HOMES LLC | B= | C | 08/30/2018 | corrections okay - photo on file | BRIANB | BRIANB | | B= | C | 5950425 |
TUSCANY HOMES LLC | B= | P | 08/29/2018 | missing min. 18" landing at rear sliding glass door / finished basement / no deck -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5949504 |
TUSCANY HOMES LLC | BIN | C | 07/13/2018 | | SHAUN | SHAUN | | BIN | C | 5902595 |
TUSCANY HOMES LLC | BFR | C | 07/13/2018 | Letter on file | SHAUN | SHAUN | | BFR | C | 5902594 |
TUSCANY HOMES LLC | BFR | P | 07/10/2018 | 3K's e.e of front second story window / 2K's e.e. window at second landing / Isolate T post in garage / Glue shims in beam pockets / Spikes in floating walls within 12" of breaks and 32" o.c. | SHAUN | SHAUN | | BFR | P | 5898489 |
TUSCANY HOMES LLC | BFR | T | 07/06/2018 | PAID (REC#1514879) inspection stopped - to many items - needs complete reinspection - met with site rep and discussed several other items/ AC1 missing LS230s T&B master bedroom / nailing incomplete THJA master bedroom / nail off H2.5 H10 master bedroom / need to splice in 3 added windows master shower / H5 missing H2.5 master shower / H1 2-play missing 2nd H2.5 master shower / missing THJA master closet / missing upper LS30s at H1 above entrance / nail of H2.5 mid stair landing HE / nail off THJA over front entrance | LONNYS | LONNYS | | BFR | T | 5895271 |
TUSCANY HOMES LLC | BFR | T | 07/02/2018 | PAID (REC#1513972) inspection stopped / to many items to list - needs complete reinspection | LONNYS | LONNYS | | BFR | T | 5891364 |
TUSCANY HOMES LLC | BSP | P | 06/07/2018 | Front porch inspection / front porch post and lid okay | SHAUN | SHAUN | | BSP | P | 5867892 |
TUSCANY HOMES LLC | BFD | C | 04/04/2018 | foundation inspections completed | BRIANB | BRIANB | | BFD | C | 5806897 |
TUSCANY HOMES LLC | BFN | C | 04/04/2018 | Engineer letter for foundation -- Eufer noted | BRIANB | BRIANB | | BFN | C | 5806894 |
TUSCANY HOMES LLC | BFT | C | 04/04/2018 | Engineers observation Letter on file | BRIANB | BRIANB | | BFT | C | 5806892 |
TUSCANY HOMES LLC | BFD | P | 04/03/2018 | need to complete BFN and BFT / drain is entire OK - damp proofing OK | LONNYS | LONNYS | | BFD | P | 5806610 |
TUSCANY HOMES LLC | BFN | P | 04/03/2018 | pending copy foundation wall observation letter / foundation design on file / soils letter on file / 2000 psf / drain usable space | BRIANB | BRIANB | | BFN | P | 5805729 |
TUSCANY HOMES LLC | BFT | P | 04/03/2018 | pending copy of foundation footing observation letter | BRIANB | BRIANB | | BFT | P | 5805727 |
MEYER ELECTRIC | E= | C | 08/28/2018 | | CHIPO | CHIPO | | E= | C | 5947540 |
MEYER ELECTRIC | E= | R | 08/27/2018 | no power to powder room fan-----finish furnace run-----install 2 floor boxes and receptacles----Notes: A/C pre-wire only | CHIPO | CHIPO | | E= | R | 5946265 |
MEYER ELECTRIC | ER | C | 06/29/2018 | | CRAIGS | CRAIGS | | ER | C | 5889611 |
MEYER ELECTRIC | ES | C | 06/28/2018 | Residential Underground: 200 amp 3/w -- new res | CRAIGS | CRAIGS | | ES | C | 5888315 |
MEYER ELECTRIC | ER | R | 06/28/2018 | add receptacle to basement stair well wall to meet the 6' rule ---- no multi wire --- no central vac --- finished basement | CRAIGS | CRAIGS | | ER | R | 5888314 |
MEYER ELECTRIC | ES | L | 06/27/2018 | see rough notes | CRAIGS | CRAIGS | | ES | L | 5886938 |
MEYER ELECTRIC | ER | L | 06/27/2018 | fresh poured concrete at the entrances --- please post address | CRAIGS | CRAIGS | | ER | L | 5886922 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/27/2018 | Correction made | MARKB | MARKB | | H= | C | 5945875 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/24/2018 | Turn furnace discharge so it is pointed away from siding. Rest OK. | MARKB | MARKB | | H= | P | 5945720 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/23/2018 | Vent termination needs to match furnace install instructions. Undercut basement bedroom door. Note: High/Low transfer to mech room and No A/C | MARKB | MARKB | | H= | P | 5944086 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 06/28/2018 | RELEASE METER | MARKB | MARKB | | HC | C | 5889073 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 06/28/2018 | Corrections made | MARKB | MARKB | | HRR | C | 5889065 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 06/27/2018 | STOPPED INSPECTION....SEAL SUPPLY ABOVE GARAGE DOOR, UNABLE TO VERIFY B-VENT CLEARANCES ON MAIN LEVEL DUE TO INSULATION, REPAIR DAMAGED FLEX IN ATTIC, OUTSIDE AIR IS NO LONGER USED FOR COMBUSTION AIR AND NEEDS BAROMETRIC OR MOTORIZED DAMPER WITH ACCESS, MIGHT BE MORE? (NOTE ADDED 6/27/18 BY MATT MORGAN----CALLED ROGER FROM MITCHELL, IGNORE COMMENT ABOUT OUTSIDE AIR REQUIRING DAMPER. OUTSIDE AIR IS BEING USED AS COMBUSTION AIR AND IS OK) NOTES: FINISHED BASEMENT, HI/LO GRILLS TO MECHANICAL ROOM, DIRECT VENT FURNACE, A/C ROUGH COIL AND LINE SET | MATTM | MATTM | | HRR | R | 5887051 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | C | 06/25/2018 | 10# test ok. Note: 11/4" blk - 1 furnace, 1 water heater, 1 fireplace and 1 kitchen range. | PAULO | PAULO | | HI | C | 5884704 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | T | 06/21/2018 | PAID (REC#1510033): DEFECTIVE GAUGE - AIR STILL IN PIPING SYSTEM WHEN GAUGE READS ZERO. Note: 11/4" blk - 1 furnace, 1 water heater, 1 fireplace and 1 kitchen range | MARKB | MARKB | | HI | T | 5881903 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | R | 06/19/2018 | Defective gauge - stays at 10 psi when pressure is let out. Re inspect all | MARKB | MARKB | | HI | R | 5879305 |
FAIRWAY PLUMBING & HEATING, INC. | P= | C | 08/28/2018 | finished basement, 3/4'' pvb installed | TED | TED | | P= | C | 5947693 |
FAIRWAY PLUMBING & HEATING, INC. | PTO | C | 06/28/2018 | | JACK | JACK | | PTO | C | 5889079 |
FAIRWAY PLUMBING & HEATING, INC. | PB | C | 04/12/2018 | ok, water under footer | TED | TED | | PB | C | 5814931 |