CASCO ENTERPRISES, INC. | B= | C | 11/09/2018 | | BOBF | BOBF | | B= | C | 6022364 |
CASCO ENTERPRISES, INC. | B= | C | 11/09/2018 | | BOBF | BOBF | | B= | C | 6022266 |
CASCO ENTERPRISES, INC. | B= | P | 11/01/2018 | Temp CO: TCO pending Building Final ( Expires: 12/1/2018 12:00:00 AM) | MATTHEWM | MATTHEWM | | B= | P | 6013665 |
CASCO ENTERPRISES, INC. | B= | P | 11/01/2018 | gap between columns and guard on deck is greater than 4" / need air barrier over insulation in mech room, rest of house okay -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 6013644 |
CASCO ENTERPRISES, INC. | BLA | C | 08/09/2018 | | BOBF | BOBF | | BLA | C | 5929779 |
CASCO ENTERPRISES, INC. | BLA | R | 08/03/2018 | weep screed to be a minimum 1/2" above front porch and rear patio | BOBF | BOBF | | BLA | R | 5924000 |
CASCO ENTERPRISES, INC. | BIN | P | 07/30/2018 | pending completion of frame, insulation okay | BOBF | BOBF | | BIN | P | 5918440 |
CASCO ENTERPRISES, INC. | BFR | P | 07/30/2018 | need to complete splice for added window, all other items okay | BOBF | BOBF | | BFR | P | 5918439 |
CASCO ENTERPRISES, INC. | BFR | P | 07/30/2018 | letter for front porch framing on file | BOBF | BOBF | | BFR | P | 5917239 |
CASCO ENTERPRISES, INC. | BFR | P | 07/23/2018 | strap top plate at gas line east side of garage / fire block incomplete top of upper level fireplace / T08E missing H2.5 mid bearing master bedroom / splice in added window master closet / tie in top plates left side front entrance / ridge beam for front porch cover missing BC6 caps TandB over front entrance header / need detail for floor framing opening over 8' left of walkout slider / glue shims in beam pockets / OK to insulate as long as items are not covered | LONNYS | LONNYS | | BFR | P | 5911143 |
CASCO ENTERPRISES, INC. | BSP | P | 07/12/2018 | front porch with posts okay | BOBF | BOBF | | BSP | P | 5901351 |
CASCO ENTERPRISES, INC. | BSP | P | 07/12/2018 | letter for front porch framing on file, still need onsite inspection to verifyLST 18 straps at rafters per letter | BOBF | BOBF | | BSP | P | 5900170 |
CASCO ENTERPRISES, INC. | BSP | R | 07/06/2018 | hardware connections at front porch not per plan, LSTA straps not installed over peaks of rafters / front porch post connections okay | BOBF | BOBF | | BSP | R | 5895676 |
CASCO ENTERPRISES, INC. | BSP | P | 06/29/2018 | floating wall and insulation at mech room where communication radiant heat controls will be installed okay | BOBF | BOBF | | BSP | P | 5890433 |
CASCO ENTERPRISES, INC. | BSP | R | 06/26/2018 | missing VPA2 at bottom of rafters, h 2.5 at rafter to top beam and LSTA 24 straps across top of rafters of front porch, front porch posts are covered can not verify post bases / rear porch with posts okay | BOBF | BOBF | | BSP | R | 5886298 |
CASCO ENTERPRISES, INC. | BFN | C | 05/22/2018 | | BOBF | BOBF | | BFN | C | 5851582 |
CASCO ENTERPRISES, INC. | BFT | C | 05/22/2018 | design on file 3000# | BOBF | BOBF | | BFT | C | 5851580 |
CASCO ENTERPRISES, INC. | BFI | C | 05/21/2018 | letter for foundation insulation on file | BOBF | BOBF | | BFI | C | 5850272 |
CASCO ENTERPRISES, INC. | BFT | P | 05/21/2018 | still need foundation design | BOBF | BOBF | | BFT | P | 5850267 |
CASCO ENTERPRISES, INC. | BFN | P | 05/21/2018 | open hole 3000# and letter for footing, steel and eufer on file, still need foundation design | BOBF | BOBF | | BFN | P | 5850262 |
CASCO ENTERPRISES, INC. | BSP | P | 05/17/2018 | Need to complete all required foundation inspections - 6x6 posts at front porch ok top and bottom - Training with Tim | BOBF | BOBF | | BSP | P | 5848634 |
CASCO ENTERPRISES, INC. | BFT | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5788464 |
CASCO ENTERPRISES, INC. | BFN | P | 03/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5788463 |
TRUSTED ELECTRIC | E= | C | 10/30/2018 | corrections made | CHIPO | CHIPO | | E= | C | 6010856 |
TRUSTED ELECTRIC | E= | P | 10/30/2018 | ADD OUTLET IN GUEST BEDROOM---GFCI IN MASTER CLOSET---OUTLET IN GARAGE NOT WORKING--- | GREGM | GREGM | | E= | P | 6010032 |
TRUSTED ELECTRIC | E= | R | 10/29/2018 | NOT READY---- | GREGM | GREGM | | E= | R | 6008619 |
TRUSTED ELECTRIC | ER | C | 07/20/2018 | | RANDY | RANDY | | ER | C | 5909150 |
TRUSTED ELECTRIC | ES | C | 07/11/2018 | Residential Underground: 200 - amp 3 Wire new service, ok to set meter / | CRAIG | CRAIG | | ES | C | 5899906 |
TRUSTED ELECTRIC | EUG | C | 06/27/2018 | 4/0 urd | TOMC | TOMC | | EUG | C | 5887009 |
AMERICAN PRIDE PLUMBING | H= | C | 10/30/2018 | Notes-- direct vent water heater. AC complete. Finished basement. | JEFFL | JEFFL | | H= | C | 6010581 |
CUSTOM CLIMATE CONTROL | H= | C | 10/30/2018 | Notes-- direct vent water heater. AC complete. Finished basement. | JEFFL | JEFFL | | H= | C | 6010574 |
CUSTOM CLIMATE CONTROL | HC | C | 07/18/2018 | RELEASE METER | BENH | BENH | | HC | C | 5907220 |
CUSTOM CLIMATE CONTROL | HRR | C | 07/18/2018 | | BENH | BENH | | HRR | C | 5907219 |
AMERICAN PRIDE PLUMBING | HI | C | 07/17/2018 | GAS STUB IS FOR FUTURE GENERATOR. | KYLEW | KYLEW | | HI | C | 5904805 |
CUSTOM CLIMATE CONTROL | HRR | P | 07/17/2018 | INSTALL MISSING 5" HEAT RUN BAR AREA. NOTES: FINISHED BASEMENT, A/C ROUGH COIL AND LINE SET, DIRECT VENT BOILER. | KYLEW | KYLEW | | HRR | P | 5904799 |
AMERICAN PRIDE PLUMBING | HI | P | 07/09/2018 | 10 LB TEST OK. WHAT IS THE STUB OUTSIDE THE GARAGE FOR? WHAT IS THE BTU LOAD FOR IT? 2" MAIN, 1 BOILER, 1 RANGE, 1 BBQ, 2 FIREPLACES, 1 UNKNOWN. | KYLEW | KYLEW | | HI | P | 5896964 |
AMERICAN PRIDE PLUMBING | HWP | P | 06/12/2018 | 2@60 lbs ok for entire main level of house. | MARK | MARK | | HWP | P | 5872620 |
AMERICAN PRIDE PLUMBING | HWP | L | 06/11/2018 | FIELD CANCELLED BY CONTRACTOR | MATTM | MATTM | | HWP | L | 5870327 |
AMERICAN PRIDE PLUMBING | HWP | P | 05/23/2018 | 1- 62LB TEST OK. R-6.65 INSULATION IN PLACE, OK TO COVER GARAGE FLOOR | BILLS | BILLS | | HWP | P | 5853538 |
AMERICAN PRIDE PLUMBING | HWP | P | 05/14/2018 | 3- 65 LB TEST OK, R-5 INSULATION IN PLACE, OK TO COVER IN BASEMENT | BENH | BENH | | HWP | P | 5844525 |
AMERICAN PRIDE PLUMBING | P= | C | 10/31/2018 | corrections made | JOSEPHD | JOSEPHD | | P= | C | 6011805 |
AMERICAN PRIDE PLUMBING | P= | P | 10/30/2018 | backflow for boiler needs to be on the house side of pressure regulator, drain at backflow needs an air gap, need hammer arrestor at basement dishwasher, missing aav @ basement south end lav, rest ok note:finished basement, potable water certification in images | JOSEPHD | JOSEPHD | | P= | P | 6010443 |
AMERICAN PRIDE PLUMBING | PWO | C | 06/13/2018 | need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5873531 |
AMERICAN PRIDE PLUMBING | PTO | C | 06/11/2018 | Test ok, aav powder lav-basement bed # 2 South lav - bar sink - mech room floor drain, finish basement, no irrigation. note: need PWO and potable water cert, check water heater at final. | DANR | DANR | | PTO | C | 5871018 |
AMERICAN PRIDE PLUMBING | PB | C | 05/01/2018 | | JOSEPHD | JOSEPHD | | PB | C | 5832352 |
CASCO ENTERPRISES, INC. | XBS | P | 06/28/2018 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: IECC only - revised basement walls | SHELLEY | SHELLEY | | XBS | P | 5888397 |