OAKSBURY HOMES | B= | C | 12/14/2018 | Item corrected | DAKOTAB | DAKOTAB | | B= | C | 6053622 |
OAKSBURY HOMES | B= | R | 12/13/2018 | Missing code compliant guardrail at front entry steps. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | SHAUN | SHAUN | | B= | R | 6051894 |
OAKSBURY HOMES | B= | P | 12/12/2018 | Need gaurdrail by entry steps - Need to fill all holes with low voltage wires in eaves - Need air barrier on exterior wood ramed wall in mechanical room - Need tip outs or drains on downspouts by gas meter - Rear covered patio - Rear deck no stairs - Rear upper deck no stairs - No AC -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TIMOTHYS | TIMOTHYS | | B= | P | 6051156 |
OAKSBURY HOMES | BLA | C | 08/06/2018 | | BOBF | BOBF | | BLA | C | 5925453 |
OAKSBURY HOMES | BLA | P | 08/03/2018 | Need to seal all penetrations through building paper | TIMOTHYS | TIMOTHYS | | BLA | P | 5923408 |
OAKSBURY HOMES | BIN | C | 08/02/2018 | | BOBF | BOBF | | BIN | C | 5922655 |
OAKSBURY HOMES | BFR | C | 08/02/2018 | | BOBF | BOBF | | BFR | C | 5922653 |
OAKSBURY HOMES | BIN | P | 08/01/2018 | pending completion of frame, insulation okay | BOBF | BOBF | | BIN | P | 5921302 |
OAKSBURY HOMES | BFR | P | 08/01/2018 | still need st 18 straps at 6 x posts each side of slider in master / remove float blocks | BOBF | BOBF | | BFR | P | 5921295 |
OAKSBURY HOMES | BFR | P | 07/30/2018 | shim trimmers and point load posts throughout / THAJ 26 at hip trusses connected to T10G / st 18 at 4 x posts each side of master bedroom slider / 2 TBE 6 and HTS 20 on south end and 2 h 2.5 at north end of G05 / isolate monoposts throughout basement / remove float blocks / complete drafstop / okay to insulate | BOBF | BOBF | | BFR | P | 5918415 |
OAKSBURY HOMES | BTR | C | 07/26/2018 | | DALE | DALE | | BTR | C | 5915292 |
OAKSBURY HOMES | BSP | P | 07/25/2018 | Garage portal frame ok | TIMOTHYS | TIMOTHYS | | BSP | P | 5913951 |
OAKSBURY HOMES | BSP | P | 07/18/2018 | front deck frame and 2 piers okay / front porch posts okay | BOBF | BOBF | | BSP | P | 5907096 |
OAKSBURY HOMES | BSP | P | 07/17/2018 | front deck piers not on plan / can not see straps at front porch / rear deck ok | DALE | DALE | | BSP | P | 5905627 |
OAKSBURY HOMES | BSP | P | 06/20/2018 | Missing front porch post -- Missing MTS12 and ST18 on front porch beams -- Upper rear porch post and lid OK | DAKOTAB | DAKOTAB | | BSP | P | 5880677 |
OAKSBURY HOMES | BSP | P | 06/20/2018 | 2 piers for front porch post OK | DAKOTAB | DAKOTAB | | BSP | P | 5880675 |
OAKSBURY HOMES | BSP | P | 05/15/2018 | 4 deck piers at back of house okay | BOBF | BOBF | | BSP | P | 5845647 |
OAKSBURY HOMES | BFI | C | 04/03/2018 | 24" R-10 okay | SHAUN | SHAUN | | BFI | C | 5806408 |
OAKSBURY HOMES | BFD | C | 04/03/2018 | Drain around habitable space / Gravity outfall 2 locations e.e. of home to the west / Damp proofing okay | SHAUN | SHAUN | | BFD | C | 5806397 |
OAKSBURY HOMES | BFN | C | 04/03/2018 | Footing and foundation observations with eufer / Foundation design 3,000 psf / Open hole report 3,000 psf / Soils report - float, Isolate, 10 % grade, Drain around habitable space / Drain design | SHAUN | SHAUN | | BFN | C | 5806396 |
OAKSBURY HOMES | BFT | C | 04/03/2018 | Footing and foundation observations with eufer / Foundation design 3,000 psf / Open hole report 3,000 psf / Soils report - float, Isolate, 10 % grade, Drain around habitable space / Drain design | SHAUN | SHAUN | | BFT | C | 5806388 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 12/10/2018 | | BRET | BRET | | E= | C | 6047624 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 12/07/2018 | missing receptacle upper master deck, relocate receptacle under master tub so that it is accessible, no power to receptacle in wine room, strap pvc to hot tub disconnect and well. could not get soffit receptacle to switch on where is switch located?, note: a/c hot tub and vac pre-wire. | BRET | BRET | | E= | R | 6046897 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 07/20/2018 | Residential Underground: 200 amp service new res. | BRET | BRET | | ES | C | 5909966 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 07/20/2018 | #6 al steamer, hot tub ,oven and a/c, no mcc, vac wired , ir ufer, #2 sub panel. | BRET | BRET | | ER | C | 5909956 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 06/06/2018 | 4/0-4/0-2/0 trench ribbon not on site ok'd by Dean | BRET | BRET | | EUG | C | 5866986 |
GENE'S HEATING AND AIR LLC | H= | C | 11/27/2018 | NOTES: FINISHED BASEMENT, LOUVER DOOR TO MECHANICAL ROOM, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C ROUGH COIL AND LINE SET X1 | BENH | BENH | | H= | C | 6034991 |
GENE'S HEATING AND AIR LLC | HRP | C | 08/07/2018 | 400 LB TEST OK | BENH | BENH | | HRP | C | 5926443 |
GENE'S HEATING AND AIR LLC | HC | C | 07/27/2018 | RELEASE METER | BENH | BENH | | HC | C | 5916573 |
GENE'S HEATING AND AIR LLC | HRR | C | 07/27/2018 | | BENH | BENH | | HRR | C | 5916559 |
GENE'S HEATING AND AIR LLC | HRR | P | 07/23/2018 | Basement level duct design doesn't match, shows an 8x8 trunk line feeding main floor, round duct installed, supposed to be a 6" and a 7" feeding kitchen, 2 6" installed. Main floor duct design does not match. Support dryer exhaust every 4 feet. All Selkirk vents within 10 feet of adjacent wall to be 2 feet higher than wall and might require enclosure. B-vent supplying water heater within 8 feet of adjacent wall to be 2 feet higher than wall and might require enclosure. BY FINAL: Properly secure intake to furnace that is serving upper level. Provide proper equipment specs for 4 ton ADP coil. NOTES: Finished basement. Outside air to furnace return with motorized dampers x2. Direct vent furnace x2. A/C Rough coil and line-set to furnace serving main level. | RANDYB | RANDYB | | HRR | P | 5911473 |
L & L GAS SHOP, LLC. | HI | C | 07/06/2018 | CONTRACTOR STATED THE GARAGE HEATER IS 75K | KYLEW | KYLEW | | HI | C | 5894625 |
L & L GAS SHOP, LLC. | HI | P | 07/05/2018 | WHAT IS THE BTU LOAD OF THE GARAGE HEATER? ALL PIPING SIZES APPROPRIATELY BUT THE 3/4" GOING TO THE GARAGE HEATER OS GOOD FOR 104K LOAD. 10 LB TEST OK. 1 1/2" MAIN, 2 FURNACES, 2 WATER HEATERS, 2 FIREPLACES, 1 COOK TOP, 1 BBQ | KYLEW | KYLEW | | HI | P | 5893570 |
GENE'S HEATING AND AIR LLC | HRR | R | 06/22/2018 | NOT READY TOO MANY ITEMS TO LIST RE-INSPECT ALL | BENH | BENH | | HRR | R | 5883257 |
TIMBERWOLF PLUMBING, INC. | P= | C | 12/10/2018 | correction made see image (ventilation for steamer) | JOSEPHD | JOSEPHD | | P= | C | 6047144 |
TIMBERWOLF PLUMBING, INC. | P= | P | 12/07/2018 | potable water certification in images | JOSEPHD | JOSEPHD | | P= | P | 6045610 |
TIMBERWOLF PLUMBING, INC. | P= | P | 12/06/2018 | need potable water test, manufacturer instructions call for ventilated space, rest ok note: finished basement, RP at side of house | JOSEPHD | JOSEPHD | | P= | P | 6044917 |
TIMBERWOLF PLUMBING, INC. | PTO | C | 07/19/2018 | note: finished basement(2 baths finished), check well tank connections at final, need pump access at master tub at final, need tempering for master tub at final, aav @ wet bar, laundry tub, basement bath RH side of house lav to back side of house, cwv @ upstairs bath lav near closet, | JOSEPHD | JOSEPHD | | PTO | C | 5907978 |
HOMEOWNER | PWO | C | 06/28/2018 | will need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5888662 |
TIMBERWOLF PLUMBING, INC. | PB | C | 04/12/2018 | | SHANEN | SHANEN | | PB | C | 5815272 |
OAKSBURY HOMES | XMS | T | 07/27/2018 | PAID (REC#1558814): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: REVISED HEATLOSS CALCULATIONS AND DUCT DESIGNS | JUSTINC | JUSTINC | | XMS | T | 5916097 |
OAKSBURY HOMES | XBS | P | 07/11/2018 | PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise roof framing | MICHAELA | MICHAELA | | XBS | P | 5899102 |