HOMEOWNER | B= | P | 04/21/2020 | letter for piers on file/corrections complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | SCOTTS | SCOTTS | | B= | P | 6547083 |
HOMEOWNER | B= | P | 04/21/2020 | provide letter for piers per previous request -- attach egress ladder -- extend downspouts -- finished basement/rear deck -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | SCOTTS | SCOTTS | | B= | P | 6546927 |
HOMEOWNER | BFT | C | 04/21/2020 | | SCOTTS | SCOTTS | | BFT | C | 6546918 |
HOMEOWNER | BSP | P | 10/07/2019 | will need eng. observation for deck piers / deck frame ok | DALE | DALE | | BSP | P | 6360501 |
HOMEOWNER | BE | L | 03/01/2019 | Renewed at 3/1/2019 12:36:40 PM | TERRI | TERRI | | BE | L | 6121531 |
HOMEOWNER | BLA | C | 08/17/2018 | | SCOTTS | SCOTTS | | BLA | C | 5937460 |
HOMEOWNER | BIN | C | 08/17/2018 | | SCOTTS | SCOTTS | | BIN | C | 5937459 |
HOMEOWNER | BFI | C | 08/17/2018 | 2" R10 @ 24" | SCOTTS | SCOTTS | | BFI | C | 5937457 |
HOMEOWNER | BFR | P | 08/14/2018 | received open hole letter and soils letter onsite / 1000 psf / drain usable space | BRIANB | BRIANB | | BFR | P | 5933663 |
HOMEOWNER | BFR | P | 08/10/2018 | complete BFT | SCOTTS | SCOTTS | | BFR | P | 5931289 |
HOMEOWNER | BFI | P | 08/10/2018 | pending verification of foundation insulation | SCOTTS | SCOTTS | | BFI | P | 5931288 |
HOMEOWNER | BFD | P | 08/10/2018 | drain observation on file -- complete BFT | SCOTTS | SCOTTS | | BFD | P | 5931284 |
HOMEOWNER | BFN | P | 08/10/2018 | complete BFT -- footing and foundation observation on file/eufer noted | SCOTTS | SCOTTS | | BFN | P | 5931283 |
HOMEOWNER | BFT | P | 08/10/2018 | provide soils report and open excavation observation | SCOTTS | SCOTTS | | BFT | P | 5931278 |
HOMEOWNER | BFR | R | 08/07/2018 | no inspection performed -- complete BFT/BFN/BFD/ footing and foundation observation/drain observation/soils report and open excavation observation | SCOTTS | SCOTTS | | BFR | R | 5925954 |
HOMEOWNER | BFR | R | 08/01/2018 | complete BFT/BFN/BFD submit all 3rd party engineering -- not dried in/missing windows and doors -- HUS26 require 3 1/2" 16d nails or simpson approved alternative -- anchor bolt within 12" of plate break rear of 3rd car -- missing ST22's per A note on frame | SCOTTS | SCOTTS | | BFR | R | 5921185 |
HOMEOWNER | BTR | C | 06/26/2018 | | SCOTTS | SCOTTS | | BTR | C | 5885939 |
HOMEOWNER | BTR | P | 06/22/2018 | missing battens left of porch -- rest ok | SCOTTS | SCOTTS | | BTR | P | 5882946 |
HOMEOWNER | BSP | P | 06/14/2018 | portal frame ok | SCOTTS | SCOTTS | | BSP | P | 5874357 |
HOMEOWNER | BSP | P | 06/07/2018 | front porch posts now ok //update//portal wall nailing incomplete at this time | SCOTTS | SCOTTS | | BSP | P | 5868227 |
HOMEOWNER | BSP | R | 06/01/2018 | plans call for front porch post caps to be BC4s - LPC4s installed / front porch lid OK | LONNYS | LONNYS | | BSP | R | 5862554 |
HOMEOWNER | E= | C | 04/03/2020 | FINAL INSP. WAS DONE 4/25/19 ---- | GREGM | GREGM | | E= | C | 6530773 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 04/25/2019 | E= OK ------40 AMP A/C ------- | GREGM | GREGM | | E= | C | 6177908 |
HOMEOWNER | E= | R | 07/24/2018 | not ready for final inspection ---- final called in after sheetrock and when all devices and lights are installed | TOMC | TOMC | | E= | R | 5912399 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 07/16/2018 | 200-amp 3 wire new service ok to energize per Craig. --------------notification sent to CSU, should be MTVE------------------ | DEAN | DEAN | | ES | C | 5903542 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | C | 07/12/2018 | 250 kcmil alum OK | CRAIGS | CRAIGS | | EUG | C | 5900696 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 07/12/2018 | Residential Underground: 200 amp 3/w new res | CRAIGS | CRAIGS | | ES | C | 5900694 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 07/12/2018 | NO multi--- hot tub prewire --- finished basement --- irr ufer --- no central vac | CRAIGS | CRAIGS | | ER | C | 5900668 |
HOMEOWNER | ES | L | 04/27/2018 | please post address ---- not sure what I was to look at the service on the pole is energized --- could not tell if I was at the right property for sure | CRAIGS | CRAIGS | | ES | L | 5829285 |
HOMEOWNER | H= | C | 04/20/2020 | Note / Finished basement / High/low combustion air / No outside air to furnace return / Indirect vent furnace / Direct vent tank less water heater / A/C complete / SEE IMAGES. | PAULO | PAULO | | H= | C | 6545101 |
HOMEOWNER | H= | P | 04/16/2020 | need installation manual to furnace for vent termination installations and clearances. Note / Finished basement / High/low combustion air / No outside air to furnace return / Indirect vent furnace / Direct vent tank less water heater / A/C complete / | PAULO | PAULO | | H= | P | 6542739 |
HOMEOWNER | H= | P | 03/13/2020 | HIGH/LOW GRILLS TO MECHANICAL ROOM ARE UNDERSIZED. REFER TO 2015 IRC SEC G2407.5.3.1 AND G2407.10. CONTINUE LINE-SET INSULATION ALL THE WAY TO SUCTION LINE COIL CONNECTION. SECURE CONDENSATE DRAIN FOR FURNACE AND COIL TO FLOOR DRAIN WITH PROPER SLOPE. WATER LINE TO HUMIDIFIER LEAKING ON TOP OF FURNACE AT TIME OF INSPECTION. CONDENSATE TUBING FOR WATER HEATER NEEDS LACKS AIR GAP AT FLOOR DRAIN. WILL NEED FURNACE INSTALLATION INSTRUCTIONS AT NEXT INSPECTION. CONDENSING UNIT TO BE FULLY SUPPORTED AT EXTERIOR, LACKS 30" SERVICE CLEARANCE ON SERVICE SIDE. REMOVE SCREEN IN DRYER TERMINATION HOOD NOTE / FINISHED BASEMENT / PRE-EXISTING OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT TANKLESS WATER HEATER / HIGH/LOW GRILLS INTO MECHANICAL ROOM / A/C COMPLETE / | WHITNEYH | WHITNEYH | | H= | P | 6510145 |
HOMEOWNER | HRR | C | 07/31/2018 | | KYLEW | KYLEW | | HRR | C | 5919474 |
HOMEOWNER | HRR | L | 07/31/2018 | CALL AHEAD AT 11:05. NEW HOME LOCKED. NO ONE ON SITE. LEFT DOOR TAG AT 11:50. | KYLEW | KYLEW | | HRR | L | 5919112 |
GLASER ENERGY GROUP INC. | HO | C | 07/27/2018 | 10 LB TEST OK. VERIFY REGULATORS AT FINAL. | KYLEW | KYLEW | | HO | C | 5916492 |
HOMEOWNER | HRR | P | 07/24/2018 | TALKED TO CONTRACTOR AND HE STATED THE BASEMENT WILL NOT HAVE A FIREPLACE. STILL NEED TO HAVE WATER HEATER SET. | KYLEW | KYLEW | | HRR | P | 5911872 |
SPRINGS GAS, INC. | HI | C | 07/19/2018 | 10 LB Test okay. 1" Main. 1 Furnace. 1 Water heater. 1 Fireplace. | RANDYB | RANDYB | | HI | C | 5908597 |
HOMEOWNER | HI | R | 06/05/2018 | GAS PIPE IS NOT INSTALLED . | LIDO | LIDO | | HI | R | 5865445 |
HOMEOWNER | HRR | P | 06/05/2018 | PLAN SHOWS FIREPLACE ON MAIN LEVEL AND IN BASEMENT, THERE IS FRAMING ON MAIN LEVEL FOR A FIREPLACE AND PARTIAL FRAMING IN BASEMENT FOR A FIREPLACE / FIREPLACES AND VENTS WILL NEED TO BE INSTALLED FOR HRR INSPECTION . WATER HEATER AND VENT WILL ALSO NEED TO BE INSTALLED FOR HRR INSPECTION .MISSING 6" SUPPLY AIR IN BASEMENT IN REC ROOM BY WALK OUT .(REST OK) NOTES: FINISHED BASEMENT, 6" OUTSIDE AIR TO RETURN AIR , NON DIRECT VENT FURNACE, AC COIL AND LINE SET ROUGH . | LIDO | LIDO | | HRR | P | 5865443 |
HOMEOWNER | P= | C | 04/06/2020 | potable water certification in images | JOSEPHD | JOSEPHD | | P= | C | 6531593 |
HOMEOWNER | P= | P | 04/03/2020 | need potable water certification, other corrections made | JOSEPHD | JOSEPHD | | P= | P | 6531287 |
HOMEOWNER | P= | P | 03/13/2020 | need potable water certification, need high loop at dishwasher, need to cap unused drain at kitchen sink, jack and jill basement lavs crossed, basement hall bath shower crossed, leak at water filters in utility room, contractor to verify tempering at master tub valve and backflow at master tub hand spray, rest ok note: finished basement, no irrigaiton | JOSEPHD | JOSEPHD | | P= | P | 6510421 |
HOMEOWNER | PWO | C | 08/01/2019 | need certificate of potable water by final | TED | TED | | PWO | C | 6285228 |
HOMEOWNER | PTO | C | 07/24/2018 | finished basement, aav bar sink | TED | TED | | PTO | C | 5912677 |
HOMEOWNER | PB | C | 05/02/2018 | correction made | TED | TED | | PB | C | 5833728 |
HOMEOWNER | PB | R | 05/01/2018 | low test dwv, note: water under footer and basement slab, no outside under ground water run to well at this time | TED | TED | | PB | R | 5832252 |