PINE CREEK CONSTRUCTION LLC | B= | C | 05/21/2019 | All other required Final inspections are complete. (This is a computer generated result) | DAKOTAB | DAKOTAB | | B= | C | 6206355 |
PINE CREEK CONSTRUCTION LLC | B= | P | 05/17/2019 | Full finished basement -- Rear deck, no stairs. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DAKOTAB | DAKOTAB | | B= | P | 6202786 |
PINE CREEK CONSTRUCTION LLC | BFR | C | 08/21/2018 | | BOBF | BOBF | | BFR | C | 5941573 |
PINE CREEK CONSTRUCTION LLC | BIN | C | 08/21/2018 | | BOBF | BOBF | | BIN | C | 5941560 |
PINE CREEK CONSTRUCTION LLC | BLA | C | 08/17/2018 | | BOBF | BOBF | | BLA | C | 5938595 |
PINE CREEK CONSTRUCTION LLC | BFR | P | 08/17/2018 | strap end walls of pop out in master bedroom / need firestop at fireplace chase in basement / 3 - 2x10 header in south west bedroom of basement / okay to insulate | BOBF | BOBF | | BFR | P | 5938592 |
PINE CREEK CONSTRUCTION LLC | BTR | C | 08/01/2018 | | BOBF | BOBF | | BTR | C | 5921241 |
PINE CREEK CONSTRUCTION LLC | BLA | R | 08/01/2018 | elevation show stucco on front of 1 car garage and entire back of garage, lath not installed / rear patio not poured, need to verify top of slab, weep screed must be a minimum of 1/2" above patio | BOBF | BOBF | | BLA | R | 5921226 |
PINE CREEK CONSTRUCTION LLC | BSP | P | 07/02/2018 | need to splice front deck to plans / pront porch trusses with posts okay, rear porch trusses with posts okay / rear deck frame with posts okay | BOBF | BOBF | | BSP | P | 5891724 |
PINE CREEK CONSTRUCTION LLC | BSP | P | 05/29/2018 | Piers ok | TIMOTHYS | TIMOTHYS | | BSP | P | 5857266 |
PINE CREEK CONSTRUCTION LLC | BFT | C | 05/23/2018 | | BOBF | BOBF | | BFT | C | 5852948 |
PINE CREEK CONSTRUCTION LLC | BFN | C | 05/23/2018 | open hole, 2000# and letter for footing, steel and eufer on file | BOBF | BOBF | | BFN | C | 5852945 |
PINE CREEK CONSTRUCTION LLC | BFD | C | 05/18/2018 | exterior and usable daylight at back of house, open hole on file 2000# | BOBF | BOBF | | BFD | C | 5850009 |
PINE CREEK CONSTRUCTION LLC | BFI | C | 05/18/2018 | R10 installed / | BOBF | BOBF | | BFI | C | 5850002 |
NASH ELECTRICAL SERVICES INC. | E= | C | 03/08/2019 | | BRET | BRET | | E= | C | 6128881 |
NASH ELECTRICAL SERVICES INC. | E= | R | 02/26/2019 | cannot use deck screws to support in-use cover and receptacle garage, strap riser, plug hole bottom of main disconnect, plug hole at a/c service receptacle, conduit for well pull must extend at least 18" below grade, cap future wires for range in sub panel, install all screws in panel covers, install arc shields on island receptacles or adjust boxes so they extend past wood panels, open box under vegetable sink, open lamp in front bedroom closet. verify breaker lock for oven unit note a/c pre-wire | BRET | BRET | | E= | R | 6118279 |
NASH ELECTRICAL SERVICES INC. | ES | C | 02/26/2019 | Residential Underground: 200-amp 3 Wire New Residence no action needed | BRET | BRET | | ES | C | 6118233 |
NASH ELECTRICAL SERVICES INC. | ES | R | 08/13/2018 | Residential Underground: plug hole bottom of main disconnect, add receptacle to front of home accessible from grade. porch receptacle doesn't meet code requirements. remember to call 2 inspections together on new home I added service inspection | BRET | BRET | | ES | R | 5932678 |
NASH ELECTRICAL SERVICES INC. | ER | C | 08/13/2018 | #* cu range, no mcc, no vac, | BRET | BRET | | ER | C | 5932674 |
NASH ELECTRICAL SERVICES INC. | EUG | C | 07/03/2018 | uf cable from structure to well head | BRET | BRET | | EUG | C | 5893302 |
NASH ELECTRICAL SERVICES INC. | EUG | C | 05/25/2018 | 4/0-4/0-4/0 | BRET | BRET | | EUG | C | 5856902 |
THE FURNACE GUY HEATING & COOLING | H= | C | 02/14/2019 | NOTES: FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C ROUGH COIL AND LINE SET X 1 | BENH | BENH | | H= | C | 6107174 |
THE FURNACE GUY HEATING & COOLING | H= | R | 12/10/2018 | NOT READY MECHANICAL ROOM LACKS COMBUSTION AIR, WATER HEATER ON LEFT IN MECHANICAL ROOM: SINGLE WALL VENT IS NOT ATTACHED TO BVENT AND NEEDS 6" CLEARANCE TO INSULATION, LAUNDRY ROOM IN BASEMENT NEEDS MAKE UP AIR, FIREPLACE MANTEL IN BASEMENT NEEDS TO BE 16" FROM TOP OF HOOD REFER TO PAGE 15 IN MANUFACTURERS INSTRUCTIONS FOR 8" MANTEL NOTES: FINISHED BASEMENT, SOLID DOOR TO MECHANICAL ROOM, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C ROUGH COIL AND LINE SET X 1 | BENH | BENH | | H= | R | 6048018 |
THORNTON PLUMBING & REPAIR, INC. | HC | C | 08/13/2018 | RELEASE METER | BENH | BENH | | HC | C | 5931584 |
THORNTON PLUMBING & REPAIR, INC. | HI | C | 08/13/2018 | 10 LB TEST OK, 1 1/2" MAIN, 2 FURNACE, 2 WATER HEATER, 3 FIREPLACE, 1 RANGE, 1 FIREPIT, 1 BBQ, 1 DRYER | BENH | BENH | | HI | C | 5931583 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 08/08/2018 | NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, A/C ROUGH COIL AND LINE SET X 1 | BENH | BENH | | HRR | C | 5927666 |
THORNTON PLUMBING & REPAIR, INC. | P= | C | 05/16/2019 | corrections made. NOTE: pvb ok | JOHNS | JOHNS | | P= | C | 6201154 |
THORNTON PLUMBING & REPAIR, INC. | P= | P | 05/15/2019 | no hot water @ mstr tub, set temps @ all tub / shwrs, need solid mission band @ kitchen drain / vent repair, **is back flow built into irrigation stub?, rest ok. NOTE: finished bsmnt, bsmnt laundry sink rough only (vtr), potable water certificate sent to scanning **INSPECTOR NOTE- note bfp @ i.s. @ next inspection | JOHNS | JOHNS | | P= | P | 6200445 |
THORNTON PLUMBING & REPAIR, INC. | P= | R | 04/16/2019 | no water pressure through out, need hammer arrestor and hi- loop at dishwasher, trap seal exceeds 4 inches at kitchen, missing full open valve at ejector discharge, need certificate of potable water, re- inspect all. | TAYLOR | TAYLOR | | P= | R | 6167036 |
THORNTON PLUMBING & REPAIR, INC. | PTO | C | 08/16/2018 | correction made | JOSEPHD | JOSEPHD | | PTO | C | 5936448 |
THORNTON PLUMBING & REPAIR, INC. | PTO | P | 08/15/2018 | not ready | JOSEPHD | JOSEPHD | | PTO | P | 5935197 |
THORNTON PLUMBING & REPAIR, INC. | PTO | P | 08/15/2018 | need to see water pipe sizing, rest ok see images floor flanges and shower drain | JOSEPHD | JOSEPHD | | PTO | P | 5934351 |
THORNTON PLUMBING & REPAIR, INC. | PTO | P | 08/14/2018 | water pipe under sized, need to anchor basement floor flanges, what type of shower drains are being used? dwv test ok note: finisehed basement, tempering in ceiling under master tub, aav @ veg sink, ejector vtr, | JOSEPHD | JOSEPHD | | PTO | P | 5933726 |
THORNTON PLUMBING & REPAIR, INC. | PWO | C | 07/25/2018 | will need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5913569 |
THORNTON PLUMBING & REPAIR, INC. | PWO | P | 07/03/2018 | ok to cover at house still need to see connection to well | JOSEPHD | JOSEPHD | | PWO | P | 5892454 |
THORNTON PLUMBING & REPAIR, INC. | PB | C | 05/30/2018 | correction made | JOSEPHD | JOSEPHD | | PB | C | 5859256 |
THORNTON PLUMBING & REPAIR, INC. | PB | P | 05/29/2018 | 2" back graded coming off 3" main right side of base, rest ok | JOSEPHD | JOSEPHD | | PB | P | 5857252 |
PINE CREEK CONSTRUCTION LLC | XBS | T | 08/09/2018 | PAID (REC#1525707): PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Revised elevations to reflect additional siding, provided deck/ porch framing plan. | BPHILLIPS | BPHILLIPS | | XBS | T | 5929211 |
PINE CREEK CONSTRUCTION LLC | XMS | T | 05/22/2018 | PAID (REC#1502048): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: REVISED HEATLOSS CALCULATIONS AND DUCT DESIGN FOR 2ND HEAT SYSTEM AND ZONING | JUSTINC | JUSTINC | | XMS | T | 5851737 |