HCC HOMES | B= | C | 03/12/2019 | | BOBF | BOBF | | B= | C | 6131960 |
HCC HOMES | B= | L | 03/11/2019 | call ahead was completed at 2:41, arrived at 3:06, waited until 3;12 no answer at door | BOBF | BOBF | | B= | L | 6130701 |
HCC HOMES | B= | R | 03/06/2019 | need to install air barriers over spray foam in floor bays in mech room / need to remove foam from b vent and create a minimum of 1" clearance, all spray foam MUST be removed from out side of B vent | BOBF | BOBF | | B= | R | 6125943 |
HCC HOMES | BSP | P | 03/01/2019 | ES report for spray foam insulation on file - ES report states states thermal barrier is required per section 4.3 of ES report provided / Need to provide 1" clearance around B vent for water heater to combustibles | JUSTINL | JUSTINL | | BSP | P | 6120985 |
HCC HOMES | B= | P | 02/27/2019 | Temp CO: partial building needed ( Expires: 3/29/2019 12:00:00 AM) | JANE | JANE | | B= | P | 6119541 |
HCC HOMES | B= | P | 02/27/2019 | 1. Missing posted address on house - To be 5" tall with 1/2" stroke / 2. Request ES report for spray foam used at rim of mech room to determine if thermal barrier is required and R value of foam at location - Spray foam applied on B bent for water heater in mech room - May need to remove foam to provide clearances to combustibles around B vent / 3. Missing air barrier at insulation in mech room / 4. Seal penetrations at gyp in garage lid // Finished basement / 2 Decks / AC installed -- Schedule a new Building Final when above items are complete. | JUSTINL | JUSTINL | | B= | P | 6119474 |
HCC HOMES | BLA | C | 12/14/2018 | Penetrations sealed | SHAUN | SHAUN | | BLA | C | 6053438 |
HCC HOMES | BLA | R | 12/13/2018 | Seal round all pipe and electrical boxes | SHAUN | SHAUN | | BLA | R | 6052235 |
HCC HOMES | BIN | C | 11/16/2018 | | BOBF | BOBF | | BIN | C | 6028521 |
HCC HOMES | BFR | C | 11/16/2018 | letter for king studs at east window of garage on file | BOBF | BOBF | | BFR | C | 6028519 |
HCC HOMES | BFR | P | 11/05/2018 | eng letter addressing items from original inspection / still need 2 kings each side of east window in garage, rest of frame okay per eng letter | BOBF | BOBF | | BFR | P | 6016292 |
HCC HOMES | BFR | R | 10/26/2018 | missing garage doors / floor joists details call for perlins on top of floor joists 2' oc throughout / need eng letter for stacked walls in stairway and in front room next to entry / h 2.5 at ledger to floor trusses where 2 x12 let in for upper deck / 2x6 bearing wall at stairway between 1st and 2nd floors, 3" sch 40 column below stee beam at entry / missing hardware each end of girder over stairway / provide eng letter for added windows in garage and next to stairs on upper level | BOBF | BOBF | | BFR | R | 6007801 |
HCC HOMES | BSP | P | 10/02/2018 | upper and lower deck frame with posts okay | BOBF | BOBF | | BSP | P | 5983322 |
HCC HOMES | BSP | P | 08/28/2018 | front porch with posts okay / post to beam at front porch okay | BOBF | BOBF | | BSP | P | 5948347 |
HCC HOMES | BFN | C | 05/21/2018 | | BOBF | BOBF | | BFN | C | 5850188 |
HCC HOMES | BFT | C | 05/21/2018 | | BOBF | BOBF | | BFT | C | 5850186 |
HCC HOMES | BSP | P | 05/18/2018 | open hole 1000#, design 1000#, letter for steel and eufer, and compaction report for pads on file | BOBF | BOBF | | BSP | P | 5849960 |
HCC HOMES | BFT | R | 04/30/2018 | no letter for compaction in plans tube, foundation still being compacted at piers while I was on site | BOBF | BOBF | | BFT | R | 5831524 |
HCC HOMES | BFN | T | 04/30/2018 | PAID (REC#1501012) no letter for foundation observation in plans tube, only approved plans | BOBF | BOBF | | BFN | T | 5831510 |
HCC HOMES | BFD | P | 04/26/2018 | need to complete BFT and BFN | LONNYS | LONNYS | | BFD | P | 5828230 |
HCC HOMES | BFN | P | 04/26/2018 | need foundation observation | LONNYS | LONNYS | | BFN | P | 5828226 |
HCC HOMES | BFT | P | 04/26/2018 | still need compaction report for exterior pads / received open hole 1000 PSF - entire / received footing observation | LONNYS | LONNYS | | BFT | P | 5828221 |
HCC HOMES | BFT | P | 04/24/2018 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 5825961 |
HCC HOMES | BFN | P | 04/24/2018 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 5825960 |
HCC HOMES | BFD | R | 04/24/2018 | need open hole to verify drain requirements / drain installed is exterior usable with out fall at south east corner / please note, will need compaction report for area where exterior pads are +/- 1 foot away from excavation cut | BOBF | BOBF | | BFD | R | 5825449 |
DUKES ELECTRIC, INC | E= | C | 02/19/2019 | no a/c | TOMC | TOMC | | E= | C | 6110985 |
DUKES ELECTRIC, INC | ER | C | 10/25/2018 | | TOMC | TOMC | | ER | C | 6005898 |
DUKES ELECTRIC, INC | ES | C | 10/24/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 6004457 |
DUKES ELECTRIC, INC | ER | R | 10/24/2018 | missing cover on recess can main level in front of powder room , main level guest room north wall receptacle spacing off , receptacle in wall master bedroom above fireplace , ? access to ufer after sheetrock ------ garage sub-panel 1 - #2 SER , 2 - #8 , upstairs sub-panel 1- #2 SER , 1 - #10 , basement sub-panel 1 - #2 SER , 1 - #10 , no mcc , no central vac , finished basement | TOMC | TOMC | | ER | R | 6004451 |
DUKES ELECTRIC, INC | EUG | C | 06/20/2018 | 250-250-3/0 | BRET | BRET | | EUG | C | 5880779 |
THE FURNACE GUY HEATING & COOLING | H= | C | 02/22/2019 | NOTES: FINISHED BASEMENT, HI/LOW GRILLE TO MECHANICAL ROOM, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, NO A/C | BENH | BENH | | H= | C | 6114416 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/22/2019 | DUCT LEAK REPORT ATTACHED, SEE IMAGES | BENH | BENH | | H= | P | 6113915 |
THE FURNACE GUY HEATING & COOLING | HC | C | 10/17/2018 | RELEASE METER | BENH | BENH | | HC | C | 5997218 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 10/17/2018 | | BENH | BENH | | HRR | C | 5997208 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 10/15/2018 | DRYER VENT ELBOW IN THE ATTIC IS 30 GAUGE, IT NEEDS TO BE 26 GAUGE, OUTSIDE AIR IS WITHIN 10 FEET OF FURNACE EXHAUST, MANUFACTURERS INSTRUCTIONS STATE THAT IF OUTSIDE AIR IS WITHIN 10 FEET OF EXHAUST, EXHAUST NEEDS TO BE 3 FEET HIGHER NOT VICE VERSA,B VENT FOR WATER HEATER NEEDS TO BE CAPPED OR INSTALLED TO WATER HEATER, BY FINAL NEED DAMPER IN OUTSIDE AIR IN ATTIC SYSTEM, REFER TO 403.5 IN 2009 IECC AND INSULATE OUTSIDE AIR TO RETURN TRUNK, BY FINAL NEED DUCT LEAK REPORT FOR ATTIC SYSTEM NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN X 2, NO A/C | BENH | BENH | | HRR | P | 5994603 |
ADEPT PLUMBING & HEATING LLC | HI | C | 09/28/2018 | BY FINAL NEED LETTER OF APPROVAL FOR 2 LB SYSTEM FROM BLACK HILLS AND REGULATOR IN PLACE, STENCILING ALREADY IN PLACE 10 LB TEST OK, #25 CSST(MEDIUM PRESSURE) 2 FURNACE, 2 WATER HEATER, 1 RANGE, 1 DRYER, 1 BBQ, 1 FIREPIT | BENH | BENH | | HI | C | 5979824 |
ADEPT PLUMBING & HEATING LLC | P= | C | 02/25/2019 | potable water cert received and sent to scanning per Jack A. ok for corrections made | JOHNS | JOHNS | | P= | C | 6116286 |
ADEPT PLUMBING & HEATING LLC | P= | P | 02/21/2019 | still need potable water cert, need dish washer set to verify secured high loop, caulk tub spout @ jack and jill upr bath, seal around upr mech hub drain, no water @ bsmnt lav, rest ok. NOTE: rp @ mech, finished bsmnt | JOHNS | JOHNS | | P= | P | 6113166 |
ADEPT PLUMBING & HEATING LLC | PTO | C | 10/19/2018 | note: finished basement, RP in mech, check well connection at final, aav @ upstairs mech room, wet bar, tempering at master tub by final | JOSEPHD | JOSEPHD | | PTO | C | 6000315 |
HOMEOWNER | PWO | C | 09/13/2018 | need certificate of potable water by final. | TAYLOR | TAYLOR | | PWO | C | 5964361 |
ADEPT PLUMBING & HEATING LLC | PB | C | 05/08/2018 | | JOSEPHD | JOSEPHD | | PB | C | 5838846 |