HOMEOWNER | B= | C | 12/04/2019 | engineer letter for rear deck framing on file - deck OK | LONNYS | LONNYS | | B= | C | 6416020 |
HOMEOWNER | BSP | R | 12/03/2019 | rear deck inspection - rear deck not built per approved design / as built has 3' cantilever - could not verify ledger connection - pier location or depth | LONNYS | LONNYS | | BSP | R | 6414641 |
HOMEOWNER | B= | P | 12/02/2019 | homeowner not on site at time of inspection - no inspection performed -- Schedule a new Building Final when above items are complete. | LONNYS | LONNYS | | B= | P | 6413046 |
HOMEOWNER | B= | R | 11/25/2019 | Rear deck framing not visible (deck low to ground and covered with snow) - no ledgerboard installed (deck anchored directly to building as seen at ends) - no footings visible (deck looks to be supported by concrete pyramid blocks on grade) - Stair handrail < 34" high (varies from 30" -34") | CHUCK | CHUCK | | B= | R | 6409547 |
HOMEOWNER | BSP | R | 11/22/2019 | Spoke with homowner/need deck spliced in. | BERTW | BERTW | | BSP | R | 6408162 |
HOMEOWNER | BSP | P | 09/06/2019 | Received engineers detail for deck frame - Inspection still needed | TIMOTHYS | TIMOTHYS | | BSP | P | 6327480 |
HOMEOWNER | BFN | C | 09/06/2019 | Received engineers observation letter for piers | TIMOTHYS | TIMOTHYS | | BFN | C | 6327478 |
HOMEOWNER | BE | C | 05/17/2019 | | RITA | RITA | | BE | C | 6202457 |
HOMEOWNER | B= | P | 11/20/2018 | still need to complete exterior cladding / grading incomplete on SE elevation / all other items OK -- Schedule a new Building Final when above items are complete. | LONNYS | LONNYS | | B= | P | 6030629 |
HOMEOWNER | B= | R | 10/19/2018 | exterior exposed OSB is not an approved exterior cladding / missing CO detector in hall / rear deck missing graspable handrail / rear deck missing landing at bottom. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | LONNYS | LONNYS | | B= | R | 5999983 |
HOMEOWNER | BIN | C | 08/22/2018 | | DALE | DALE | | BIN | C | 5943043 |
HOMEOWNER | BFR | C | 08/22/2018 | garage on separate permit | DALE | DALE | | BFR | C | 5943042 |
HOMEOWNER | BFR | P | 08/21/2018 | eng. received for studs and beam received / need garage inspected | DALE | DALE | | BFR | P | 5941311 |
HOMEOWNER | BFI | C | 08/21/2018 | eng. observation received | DALE | DALE | | BFI | C | 5941309 |
HOMEOWNER | BFT | C | 08/21/2018 | eng. observation received / soils received | DALE | DALE | | BFT | C | 5941307 |
HOMEOWNER | BFR | R | 08/20/2018 | complete bft bfi / missing 2 lat on T01 and T01A trusses / 45 brace gable ends / need 2-hts20 on porch trusses / garage not looked at at this time | DALE | DALE | | BFR | R | 5939848 |
HOMEOWNER | BFR | R | 08/16/2018 | need soils report , open hole, and pier observations to complete BFT / needs complete reinspection all trusses missing lateral bracing / all trusses missing hard wear to beams / gable ends missing strong backs / foam and fire block incomplete / all interior walls are not floating - light guage metal used in lieu of 2x4 framing / need to verify leger locks at exterior of posts / GARAGE FRAMING: truss lay out per approved plans / trusses missing all lateral bracing and hardwear / need to verify ledger locks to posts | LONNYS | LONNYS | | BFR | R | 5936263 |
HOMEOWNER | E= | C | 10/18/2018 | afci , gfci installed | TOMC | TOMC | | E= | C | 5999127 |
HOMEOWNER | ES | C | 10/18/2018 | Residential Underground: off grid house | TOMC | TOMC | | ES | C | 5999118 |
HOMEOWNER | E= | P | 10/12/2018 | move gfi from behind washer , all 120 volt 15 & 20 amp circuits ( except garage , unfinished and bathroom ) will have afci , gfci or a combination of both . the house checks out except the laundry/mech room | TOMC | TOMC | | E= | P | 5993842 |
HOMEOWNER | EP | P | 10/12/2018 | 200 ---no afci protection | TOMC | TOMC | | EP | P | 5993840 |
HOMEOWNER | ER | C | 08/15/2018 | | DEAN | DEAN | | ER | C | 5935411 |
HOMEOWNER | ER | P | 08/15/2018 | install power from solar to panel or install conduit | CRAIG | CRAIG | | ER | P | 5935223 |
HOMEOWNER | ER | R | 07/27/2018 | install well power ---------- install feeder to garage ----------- add smoke in hall way --------- make up switches and panel | CRAIG | CRAIG | | ER | R | 5917033 |
HOMEOWNER | ER | R | 07/18/2018 | not ready ------- had consultation with owner ------------- talked about Discussed AFCI/GFCI/TR requirements with owner. / dedicated 20 amp circuits ------------ need corrected plug spacing through out house -------------- install smokes ------------ make up all boxes ------------ strap all cable from boxes ------------ install panel and make up ------------- complete re inspect --------------- may need another consultation with owner | CRAIG | CRAIG | | ER | R | 5906889 |
HOMEOWNER | H= | C | 10/19/2018 | | BILLS | BILLS | | H= | C | 5999605 |
HOMEOWNER | H= | P | 10/12/2018 | NEED BACK FLOW PREVENTER AT BOILER, NEED T&P DRAIN TUBE INSTALLED ON DOMESTIC SIDE OF BOILER, T&P INSTALLED ON HEATING SIDE OF BOILER CAN NOT REDUCE IN SIZE. IF PEX IS TO BE USED FOR T&P RELIEF IT MUST BE SIZED UP 1 NOMINAL SIZE. NOTE: DIRECT VENT BOILER, RADIANT IN FLOOR HEAT, OPERABLE WINDOWS AT BATHROOMS, SOLID FUEL FREE STANDING FIREPLACE | BILLS | BILLS | | H= | P | 5993379 |
HOMEOWNER | HC | C | 08/15/2018 | RELEASE METER | BILLS | BILLS | | HC | C | 5934707 |
HOMEOWNER | HRR | C | 08/15/2018 | NOTE: DIRECT VENT BOILER, IN FLOOR RADIANT HEAT, SOLID FUEL FREE STANDING FIREPLACE | BILLS | BILLS | | HRR | C | 5934704 |
HOMEOWNER | HRR | P | 07/27/2018 | BOILER VENTS NEED TO BE CORRECT MATERIAL WITH CONTRASTING PRIMER/GLUE CONNECTIONS. CONSULTED WITH HOMEOWNERS ON VENT TERMINATION OPTIONS AND PRACTICES. | BILLS | BILLS | | HRR | P | 5916328 |
HOMEOWNER | HI | C | 07/20/2018 | 10LB TEST OK. 1" MAIN. 1 BOILER | BILLS | BILLS | | HI | C | 5909206 |
HOMEOWNER | HRR | P | 07/20/2018 | DRYER VENT NEEDS TO BE SUPPORTED EVERY 4', NEED TO SEE BOILER VENTS. NOTE: IN FLOOR RADIANT HEAT | BILLS | BILLS | | HRR | P | 5909203 |
HOMEOWNER | HI | L | 07/19/2018 | All doors locked. | RANDYB | RANDYB | | HI | L | 5908189 |
HOMEOWNER | HRR | L | 07/19/2018 | All doors locked. | RANDYB | RANDYB | | HRR | L | 5908184 |
CO. COMFORT HTG & AIR, INC. | HWP | P | 04/06/2018 | 60# test ok. insulation board ok. OK TO POUR SLAB. | PAULO | PAULO | | HWP | P | 5810575 |
HOMEOWNER | HWP | R | 04/05/2018 | low test. | PAULO | PAULO | | HWP | R | 5809089 |
HOMEOWNER | P= | C | 10/19/2018 | corrections made see images (vent & high loop) | JOSEPHD | JOSEPHD | | P= | C | 5999559 |
HOMEOWNER | P= | P | 10/18/2018 | still need hammer arrestor and hi loop at dishwasher, need verification at roof vent is connected in attic, can submit photos, other corrections made | JOSEPHD | JOSEPHD | | P= | P | 5998632 |
HOMEOWNER | PWO | C | 10/12/2018 | dirt raised by well head to meet depth | JOSEPHD | JOSEPHD | | PWO | C | 5993304 |
HOMEOWNER | P= | P | 10/12/2018 | need backflow at boiler, need proper plumbing vent flashing, need hammer arrestor and to see high loop at dishwasher, need t&p run from domestic water side of boiler, t&p for heating side can not reduce in size, rest ok note: potable water certification recived | JOSEPHD | JOSEPHD | | P= | P | 5993297 |
HOMEOWNER | PWO | P | 09/05/2018 | ok to cover at house, need to get more depth or cover around well head, will need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | P | 5955747 |
BEACON PLUMBING, LLC | PTO | C | 06/29/2018 | aav in wall for master lavs, still need pwo inspection | TED | TED | | PTO | C | 5889866 |
BEACON PLUMBING, LLC | PB | C | 03/22/2018 | still need pwo inspection | JOSEPHD | JOSEPHD | | PB | C | 5796144 |
HOMEOWNER | XBS | P | 11/22/2019 | PLAN SPLICE: (No Fee) by: DANM for Construction: 10' X 12' deck added to scope of work | DANM | DANM | | XBS | P | 6408514 |