HOMES BY MICHAEL HALL, LLC. | B= | C | 09/10/2018 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 5960030 |
HOMES BY MICHAEL HALL, LLC. | B= | P | 09/07/2018 | no a/c. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | NATHAN | NATHAN | | B= | P | 5958017 |
HOMES BY MICHAEL HALL, LLC. | BLA | C | 05/30/2018 | | NATHAN | NATHAN | | BLA | C | 5858763 |
HOMES BY MICHAEL HALL, LLC. | BIN | C | 05/09/2018 | walls and ceiling okay | NATHAN | NATHAN | | BIN | C | 5839557 |
HOMES BY MICHAEL HALL, LLC. | BFR | C | 05/08/2018 | header not on plans at the south of the front door, okay to insulate. | NATHAN | NATHAN | | BFR | C | 5838417 |
HOMES BY MICHAEL HALL, LLC. | BFI | C | 03/30/2018 | 2" RIGID 30" DEEP | NATHAN | NATHAN | | BFI | C | 5803661 |
HOMES BY MICHAEL HALL, LLC. | BFN | C | 03/30/2018 | Engineer letter for foundation -- Eufer noted / drain not required | NATHAN | NATHAN | | BFN | C | 5803660 |
HOMES BY MICHAEL HALL, LLC. | BFT | C | 03/30/2018 | Engineer letter for footing on file -- Open hole on file / | NATHAN | NATHAN | | BFT | C | 5803658 |
DOWNTOWN ELECTRIC AND LIGHTING INC | E= | C | 07/18/2018 | corrections, | GARYL | GARYL | | E= | C | 5906791 |
DOWNTOWN ELECTRIC AND LIGHTING INC | E= | R | 07/17/2018 | 1) recept in dining area within 6' of sink needs GFCI protection, 2) fill ditch or provide ladder for access to outside panel, 3) couldn't find ufer??? | GARYL | GARYL | | E= | R | 5904593 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ER | C | 05/03/2018 | | GARYL | GARYL | | ER | C | 5835039 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ES | C | 05/02/2018 | Residential Overhead: New 150 amp., 3-wire service | GARYL | GARYL | | ES | C | 5833899 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ER | R | 05/02/2018 | # 10 to dryer?? to short, and not installed/stapled correctly, looks like framers moved it, NOTES! expose ufer for final | GARYL | GARYL | | ER | R | 5833892 |
GENE'S HEATING AND AIR LLC | H= | C | 09/06/2018 | All corrections have been completed. | MARK | MARK | | H= | C | 5956392 |
ALPHALETE MECHANICAL LLC | H= | R | 09/04/2018 | On new construction, all mechanical subs fall under the mechanical final. In this case, Gene's. | MARK | MARK | | H= | R | 5953779 |
GENE'S HEATING AND AIR LLC | H= | P | 09/04/2018 | Need to undercut bedroom doors for return air path, need to give minimum 1" clearance around water heater vent at sheet rock, missing make up air to laundry. Note: Vented attic, no osa, no a/c. | MARK | MARK | | H= | P | 5953770 |
JR WHITNEY PLUMBING COMPANY | HO | C | 08/22/2018 | 10 LB Test okay. 1" PE from meter to house with tracer wire @ 175 feet. Good for 154,000 BTU's. | RANDYB | RANDYB | | HO | C | 5942084 |
GENE'S HEATING AND AIR LLC | HC | C | 05/07/2018 | RELEASE METER | MARK | MARK | | HC | C | 5838078 |
GENE'S HEATING AND AIR LLC | HRR | C | 05/07/2018 | No a/c. has osa to return, at final need access to attic to verify service switch at furnace. Note: Vented attic. | MARK | MARK | | HRR | C | 5838045 |
ALPHALETE MECHANICAL LLC | HI | C | 05/04/2018 | 10 lb test ok, 1 inch main, 1 furnace, 1 water heater. | TAYLOR | TAYLOR | | HI | C | 5836775 |
GENE'S HEATING AND AIR LLC | HRR | P | 05/02/2018 | Duct design does not match plan. missing 2 heat runs. Need proper reducer/increaser fitting at bath fan, need access to attic unit. | MARK | MARK | | HRR | P | 5833322 |
ALPHALETE MECHANICAL LLC | P= | C | 09/06/2018 | Corrections made, images uploaded from contractor. | DANR | DANR | | P= | C | 5956305 |
ALPHALETE MECHANICAL LLC | P= | P | 09/04/2018 | Trap guard water heater floor drain, need 6" clearance from pex to single connector at water heater, (pictures ok) rest ok, | DANR | DANR | | P= | P | 5953614 |
ALPHALETE MECHANICAL LLC | PTO | C | 04/24/2018 | CS UTILITIES TO INSPECT ALL OUTSIDE STRUCTURE DRAIN AND WATER LINES, corrections made, STILL NEED TO SEE WATER TIE IN AFTER METER @ EXISTING FRONT HOUSE, CAN VERIFY @ FINAL | JOHNS | JOHNS | | PTO | C | 5825068 |
ALPHALETE MECHANICAL LLC | PTO | P | 04/20/2018 | lost test @ washer box, rest ok. note: vtr (2), no irrigation stub, check water htr, expansion, and final water connections @ water entry @ final **NEED TO VERIFY HOUSE TIE IN @ WATER** | JOHNS | JOHNS | | PTO | P | 5822434 |
ALPHALETE MECHANICAL LLC | PTO | L | 04/19/2018 | field cancelled | JOHNS | JOHNS | | PTO | L | 5821112 |
ALPHALETE MECHANICAL LLC | PB | C | 04/04/2018 | waters looped under ground **NEED TO VERIFY EXISTING HOUSE TIE (AFTER WATER MTR) FOR NEW WATER LINE @ PTO** | JOHNS | JOHNS | | PB | C | 5807558 |
HOMES BY MICHAEL HALL, LLC. | XMS | T | 05/04/2018 | PAID (REC#1498371) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: mechanical splice 5-4-18 | TCRIPPEN | TCRIPPEN | | XMS | T | 5836778 |