DDR-33 | B= | C | 07/11/2018 | Window at master bath barricaded from interior with OSB until tempered window is installed / Final inspection corrections complete | JUSTINL | JUSTINL | | B= | C | 5898839 |
DDR-33 | BIN | C | 07/11/2018 | | JUSTINL | JUSTINL | | BIN | C | 5898838 |
DDR-33 | BFR | C | 07/11/2018 | Splice complete for added windows and rear deck / Engineer letter on file for garage narrow braced walls | JUSTINL | JUSTINL | | BFR | C | 5898837 |
DDR-33 | B= | T | 07/10/2018 | PAID (REC#1515280) 1. Still need to complete splice process for added windows and deck / 2. Still need to complete narrow braced wall inspection - Missing interior straps - exterior nailing covered and could not inspect ( Need to complete items 1 and 2 to complete frame) / 3. Missing posted address numbers / 4. Garage service door swings over landing - Door barricaded and rendered inoperable at time of inspection - Will need to inspect once corrected / 5. Riser height at rear deck bottom steps greater than 7 3/4" - Measure 8 3/4" / 6. Window at tub in master not tempered // Finished basement / Rear deck / AC installed | JUSTINL | JUSTINL | | B= | T | 5897852 |
DDR-33 | BSP | P | 06/18/2018 | Engineer letter for front porch framing and post cap hardware on file | JUSTINL | JUSTINL | | BSP | P | 5876942 |
DDR-33 | BLA | C | 06/11/2018 | Penetrations have been sealed and weep screeds have been corrected to 4 inches above unpaved surface. | TOMN | TOMN | | BLA | C | 5869952 |
DDR-33 | BLA | R | 05/24/2018 | Seal all penetrations on all elevations / Weep screeds on left side and right side of house need to be 4 inches above unpaved surfaces / Please correct and contact for re inspection | TOMN | TOMN | | BLA | R | 5854904 |
DDR-33 | BFD | C | 05/11/2018 | Engineer observation for drain on file | JUSTINL | JUSTINL | | BFD | C | 5841944 |
DDR-33 | BFN | C | 05/11/2018 | Engineer letter for foundation -- Eufer noted / Engineer observation for piers on file / Foundation design on file | JUSTINL | JUSTINL | | BFN | C | 5841943 |
DDR-33 | BFT | C | 05/11/2018 | Engineer letter for footing on file -- Open hole on file - 2000 PSF / Drain usable / 10% | JUSTINL | JUSTINL | | BFT | C | 5841939 |
DDR-33 | BIN | R | 05/09/2018 | Insulation OK pending completion of BFT, BFN, BFD, BFR / Request all foundation paperwork prior to further field inspections | JUSTINL | JUSTINL | | BIN | R | 5839741 |
DDR-33 | BFR | P | 05/09/2018 | 1. Request all foundation paperwork prior to any further inspections / 2. Front porch not framed per plan / 3. Missing 2nd H2.5 at I75 trusses at entry / 4. Splice for rear deck not on file - May need to complete splice process // Still to inspect garage narrow braced walls at later date as BSP / Other frame corrections complete | JUSTINL | JUSTINL | | BFR | P | 5839740 |
DDR-33 | BFR | R | 05/07/2018 | front porch lid not built per plan / front porch lid missing 2 H2.5s at garage common wall / need to splice in rear deck plan - deck OK per on site plan / girder truss 180 missing 3-2x4 post - 2 TBE4s and mts 20 EE in garage / missing third king left side of front window / missing the second H2.5 EE of several 175 - 176 AND 178 trusses / 175 trusses missing H2.5s at mid bearing in garage / missing roof jacks to dry in / strap top plates for both balloon framed walls in rear in middle and at corners / strap top plate break in master bath / wood shims in beam pocket next to mechanical room | LONNYS | LONNYS | | BFR | R | 5838145 |
DDR-33 | BFD | P | 03/21/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFD | P | 5795118 |
DDR-33 | BFT | P | 03/21/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5795117 |
DDR-33 | BFN | P | 03/21/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5795116 |
DEPAUL ELECTRIC | E= | C | 07/03/2018 | a/c installed--30 amp | TIMA | TIMA | | E= | C | 5893195 |
DEPAUL ELECTRIC | E= | R | 06/27/2018 | not ready---exterior not trimmed and other various things | TIMA | TIMA | | E= | R | 5887876 |
DEPAUL ELECTRIC | ER | C | 05/04/2018 | #6 AL to oven/range / No Cent Vac / Finished Basement / | TIMA | TIMA | | ER | C | 5836886 |
DEPAUL ELECTRIC | ES | C | 05/03/2018 | Residential Underground: 200 amp 3/w new res. needs meter set | TIMA | TIMA | | ES | C | 5835589 |
DEPAUL ELECTRIC | ER | R | 05/03/2018 | wires in air return basement hall soffit,wire out of wall in large basement bedroom above door | TIMA | TIMA | | ER | R | 5835587 |
DEPAUL ELECTRIC | EUG | C | 04/19/2018 | 250 urd | TOMC | TOMC | | EUG | C | 5821152 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/09/2018 | RECEIVED IMAGES FROM CONTRACTOR, SEE IMAGES. | MATTM | MATTM | | H= | C | 5896347 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 07/09/2018 | DRYER VENT CANNOT HAVE A SCREEN, REMOVE BOTH NAILS FROM DRYER VENT, PLEASE ENSURE BOTH ITEMS ARE TAKEN CARE OF BEFORE CALLING IN NEXT INSPECTION OR TRIP FEE WILL BE APPLIED. | MATTM | MATTM | | H= | R | 5896077 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/06/2018 | COIL EQUIPMENT CHANGE LETTER RECEIVED, SEE IMAGES. | MATTM | MATTM | | H= | P | 5894502 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/05/2018 | DRYER VENT TERMINATION CANNOT HAVE A SCREEN, REMOVE NAILS FROM DRYER VENT, GAS LEAK AT RANGE SHUT OFF---NOTIFIED GENERAL CONTRACTOR ON SITE, RECEIVED COIL CHANGE LETTER---WILL ATTACH TO PERMIT 7/6/18 NOTES: FINISHED BASEMENT, LOUVER DOOR TO MECHANICAL ROOM, NO OUTSIDE AIR TO FURNACE RETURN, A/C INSTALLED | MATTM | MATTM | | H= | P | 5893539 |
GLASER ENERGY GROUP INC. | HO | C | 05/16/2018 | NOTES: 10 LB TEST IS OK. 20' OF 1/2" PE WITH TRACER WIRE FROM THE PROPANE TANK TO THE REGULATOR. | JEFFB | JEFFB | | HO | C | 5846224 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 05/04/2018 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5836264 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 05/04/2018 | THE FURNACE SPECS ARE GOOD BUT THE A/C COIL NEEDS A CHANGE LETTER AT THE FINAL. ALSO THE BASEMENT BATHROOM HAS BEEN RELOCATED AS PER THE PRINTS. NOTES: NO DOORS TO THE FINISHED BASEMENT AND A/C ROUGH - LINES AND COIL. | JEFFB | JEFFB | | HRR | C | 5836260 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 05/01/2018 | NOTES: FIELD CANCELLED. | JEFFB | JEFFB | | HRR | R | 5832553 |
L & L GAS SHOP, LLC. | HI | C | 04/26/2018 | NOTES: 10 LB TEST IS OK. 1"MAIN FOR 1 - FURNACE, 1 - WATER HEATER, 1 - COOK TOP AND 2 - FIREPLACES. | JEFFB | JEFFB | | HI | C | 5828756 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 06/21/2018 | no irrigation stub, LP water htr | JOHNS | JOHNS | | P= | C | 5881583 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 05/02/2018 | Test ok, vtr all except bar sink, finish basement, tempering valve above man-o-block, no irrigation. | DANR | DANR | | PTO | C | 5833641 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 03/22/2018 | Test ok. | DANR | DANR | | PB | C | 5796243 |