MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | C | 11/01/2019 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 6385581 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | P | 10/31/2019 | Variance approved by Woodland Park Board of Review in images. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection N= by WP ENGINEERING is not Completed yet. | NICK | NICK | | B= | P | 6384872 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | P | 10/03/2019 | At time of inspection crawl space height is 8' from grade to floor joist at lowest spot and 7' 10" at highest location, max is 5' per RBC requirements / All other elements completed / All other aspects of final OK -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection N= by WP ENGINEERING is not Completed yet. | NICK | NICK | | B= | P | 6357097 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | B= | P | 07/10/2019 | Missing CO detectors / Need ladder to inspect attic / Need frame complete / Received eng. for steel brackets. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection N= by WP ENGINEERING is not Completed yet. | PARKER | PARKER | | B= | P | 6258611 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BIN | P | 08/14/2018 | Exterior wall insulation OK / Check attic and crawl space at final / Need frame complete | NICK | NICK | | BIN | P | 5933162 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFR | P | 08/14/2018 | Still need Eng for steel brackets in place of beam pockets / Crawl space ceiling height still at same height as previous inspection / All other items complete | NICK | NICK | | BFR | P | 5933158 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFR | P | 08/07/2018 | Need to install anchor bolts within 12" of sill plate breaks / Need to install roll blocking for F trusses / Need to install lateral bracing for F truss / Need to install lateral bracing for A2 and A3 trusses / Need to install draft stop throughout / Need Eng for use of steel plates in place of beam pockets per approved plans in crawl space / Crawl space height is 7'10" throughout from grade to bottom of floor joist, max is 5' per RBC requirements | NICK | NICK | | BFR | P | 5925898 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BLA | C | 07/17/2018 | | NICK | NICK | | BLA | C | 5904673 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFD | C | 07/17/2018 | No drain requirements on open hole report | NICK | NICK | | BFD | C | 5904672 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFN | C | 07/17/2018 | | NICK | NICK | | BFN | C | 5904670 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BSP | P | 06/28/2018 | Front and back porch frames OK / Need all Eng for footing/foundation / No inspection of drain done by RBD, will need Eng letter of observation | NICK | NICK | | BSP | P | 5888980 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFT | C | 05/25/2018 | Piers for back deck OK / Front porch pads and piers OK / Still need soils report to close out foundation / Backfilled at time of inspection, no inspection of drain done by RBD | NICK | NICK | | BFT | C | 5855971 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFN | P | 04/23/2018 | Foundation reinforcement OK per design / Open hole on file / #1500psf / Still need soils report / Still need to inspect all exterior piers and pads | NICK | NICK | | BFN | P | 5823928 |
MURPHY CONSTRUCTORS OF COLORADO SPRINGS, INC. | BFT | P | 04/17/2018 | J S2 pads not inspected at this time / Exterior piers ot inspected at this time / Footing forms and interior pads with reinforcement and eufer okay / Provide soils and open hole reports / Pour at own risk / | SHAUN | SHAUN | | BFT | P | 5818646 |
ELECTRIC TECH INC. | E= | C | 04/05/2019 | | JOHNN | JOHNN | | E= | C | 6157127 |
ELECTRIC TECH INC. | E= | R | 03/29/2019 | correction not made: bond to copper water line has been disconnected and is hanging in crawler, please re connect. | JOHNN | JOHNN | | E= | R | 6149559 |
ELECTRIC TECH INC. | E= | R | 03/27/2019 | house locked, no code, coach light still loose on front end of house, | JOHNN | JOHNN | | E= | R | 6146905 |
ELECTRIC TECH INC. | E= | R | 03/07/2019 | front coach light is very loose, outside outlets not working, where is gfci? circulation pump outlet not working, need inter syst bond term, porch outlet has large gap, cb panel missing 2 screws, crawler: nm cable laying in dirt, needs box, support nm cables to rafters, missing service outlet, bond copper water lines/ master bed rm missing switch plate, -------------------------------30 amp a/c,ok | JOHNN | JOHNN | | E= | R | 6127412 |
ELECTRIC TECH INC. | E= | L | 03/06/2019 | locked, no lock box code given, | JOHNN | JOHNN | | E= | L | 6126197 |
ELECTRIC TECH INC. | ER | C | 08/03/2018 | | JOHNN | JOHNN | | ER | C | 5924091 |
ELECTRIC TECH INC. | ES | C | 08/01/2018 | Residential Underground: 200-amp 3 Wire service, new res, no action needed | JOHNN | JOHNN | | ES | C | 5921400 |
ELECTRIC TECH INC. | ER | R | 08/01/2018 | cable is hanging outside of shower area, what is it for? has no box,----------------no mcc,rev ufer,#6al, | JOHNN | JOHNN | | ER | R | 5921399 |
ELECTRIC TECH INC. | EUG | C | 06/28/2018 | 4/0 al,4w | JOHNN | JOHNN | | EUG | C | 5889219 |
AIRTECH MECHANICAL, INC. | H= | C | 06/14/2019 | note direct vent equipment, a/c complete conditioned crawler | DAVIDH | DAVIDH | | H= | C | 6231439 |
AIRTECH MECHANICAL, INC. | H= | R | 04/30/2019 | water heater vent in mech rm requires two step process and purple primer is required also furnace termination is not complete note conditioned crawler , a/c complete | DAVIDH | DAVIDH | | H= | R | 6182423 |
DRUMMOND PLUMBING LLC | H= | R | 03/12/2019 | this is a 101 permit there is no heating final for the gas mech contractor is only one | DAVIDH | DAVIDH | | H= | R | 6131461 |
DRUMMOND PLUMBING LLC | HC | C | 09/28/2018 | release meter | DAVIDH | DAVIDH | | HC | C | 5980386 |
DRUMMOND PLUMBING LLC | HV | P | 08/06/2018 | water heater vent stubbed through to mech rm | DAVIDH | DAVIDH | | HV | P | 5924619 |
AIRTECH MECHANICAL, INC. | HRR | P | 08/03/2018 | water heater vent is still not done note direct vent furn conditioned crawler a/c line set and coil | DAVIDH | DAVIDH | | HRR | P | 5923098 |
DRUMMOND PLUMBING LLC | HI | C | 08/03/2018 | 10 lb test ok note 1 1/4" line 1 furn,w/h,range,fireplace,dryer | DAVIDH | DAVIDH | | HI | C | 5923080 |
AIRTECH MECHANICAL, INC. | HRR | R | 07/25/2018 | MISSING 5" TOE KICK IN BATH ROOM , OUTDOOR FIREPLACE, NOT SET,FURN VENT NOT RAN , KITCHEN HOOD NOT COMPLETE, BATH EXHAUST FANS NEED TO BE RAN INSULATED . ALSO NEED ANOTHER HANGER UNDER A/C EVAP COIL., ADD R/A TO CRAWLER | DAVIDH | DAVIDH | | HRR | R | 5913490 |
DRUMMOND PLUMBING LLC | P= | C | 03/18/2019 | corrections made see images (vent cap removed, tempering for master tub) | JOSEPHD | JOSEPHD | | P= | C | 6134892 |
DRUMMOND PLUMBING LLC | P= | P | 03/12/2019 | need tempering at master tub, need vent caps removed, rest ok note: no irrigation | JOSEPHD | JOSEPHD | | P= | P | 6131797 |
DRUMMOND PLUMBING LLC | PTO | C | 08/06/2018 | By final need vent and back-water valve for floor drain in crawl space, all other corrections made | SHANEN | SHANEN | | PTO | C | 5924573 |
DRUMMOND PLUMBING LLC | PTO | P | 08/03/2018 | re- grade vents and master shower drain, support all DWV and water lines through out to code, missing nail protection left master lav, need to vent floor drain at crawl space, lost test DWV at kitchen, s- trap at master tub, re- inspect all. | TAYLOR | TAYLOR | | PTO | P | 5923688 |