HOME RUN RESTORATIONS, INC. | B= | C | 10/03/2018 | serial # 17-M33519 / insignia # 33593 / unfinished basement, deck and stairs in | DALE | DALE | | B= | C | 5984711 |
HOME RUN RESTORATIONS, INC. | BIN | C | 09/24/2018 | | DALE | DALE | | BIN | C | 5974005 |
HOME RUN RESTORATIONS, INC. | BSP | P | 09/18/2018 | basement marriage line and deck frame ok | DALE | DALE | | BSP | P | 5967975 |
HOME RUN RESTORATIONS, INC. | BTD | C | 08/06/2018 | BTD okay / Foundation basement marriage wall not inspected at this time / Front porch framing not inspected t time | SHAUN | SHAUN | | BTD | C | 5925017 |
HOME RUN RESTORATIONS, INC. | BSP | R | 08/02/2018 | Foundation marriage wall doesn't match plans Headers, Trimmers, Kings and stud packs | SHAUN | SHAUN | | BSP | R | 5922042 |
HOME RUN RESTORATIONS, INC. | BFD | C | 07/10/2018 | | SCOTTS | SCOTTS | | BFD | C | 5897175 |
HOME RUN RESTORATIONS, INC. | BFN | C | 07/10/2018 | | SCOTTS | SCOTTS | | BFN | C | 5897174 |
HOME RUN RESTORATIONS, INC. | BFT | C | 07/10/2018 | soils report on file | SCOTTS | SCOTTS | | BFT | C | 5897173 |
HOME RUN RESTORATIONS, INC. | BFN | P | 07/05/2018 | complete BFT | SCOTTS | SCOTTS | | BFN | P | 5893389 |
HOME RUN RESTORATIONS, INC. | BFD | P | 07/05/2018 | provide 3rd party observation or schedule drain observation/complete BFT | SCOTTS | SCOTTS | | BFD | P | 5893388 |
HOME RUN RESTORATIONS, INC. | BFT | P | 07/05/2018 | provide soils report -- open excavation on file/footing observation on file/foundation observation on file -- foundation design on plan set/900 psf | SCOTTS | SCOTTS | | BFT | P | 5893382 |
HOME RUN RESTORATIONS, INC. | BFN | R | 07/02/2018 | see BFT notes | SCOTTS | SCOTTS | | BFN | R | 5891236 |
HOME RUN RESTORATIONS, INC. | BFT | R | 07/02/2018 | foundation poured prior to permit/contact Chief Bert Warchol -- 3rd party observations received via email | SCOTTS | SCOTTS | | BFT | R | 5891232 |
ADVANCE ELECTRIC | EP | C | 10/01/2018 | both 200 amp 4/w sub panels ok | CRAIG | CRAIG | | EP | C | 5981847 |
ADVANCE ELECTRIC | E= | C | 10/01/2018 | Irreversible UFER connection / unfinished basement / garage ok | CRAIG | CRAIG | | E= | C | 5981846 |
ADVANCE ELECTRIC | ES | C | 10/01/2018 | Residential Underground: 200 - amp 3 Wire new service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5981840 |
ADVANCE ELECTRIC | EUG | C | 08/29/2018 | 4 Wire URD from home to metal out-building due W. | JOSEPH | JOSEPH | | EUG | C | 5949621 |
ADVANCE ELECTRIC | ES | R | 08/15/2018 | At the service disconnect the grounding electrode conductor from ufer should terminate at service neutral terminal strip. You could also install a # 4 copper jumper from the equipment grounding conductor terminal strip to the service neutral terminal strip. This can be verified at final. | JOSEPH | JOSEPH | | ES | R | 5934773 |
ADVANCE ELECTRIC | ER | C | 08/15/2018 | Notes: Underground splice for service lateral good. -------- sub panel in basement and UFER good | JOSEPH | JOSEPH | | ER | C | 5934767 |
ADVANCE ELECTRIC | ES | R | 08/14/2018 | Not ready | JOSEPH | JOSEPH | | ES | R | 5933281 |
ADVANCE ELECTRIC | ER | R | 08/14/2018 | Not ready consultation only. ---------- Notes: Upstairs 200 amp sub panel good. | JOSEPH | JOSEPH | | ER | R | 5933277 |
WESTMAN HEATING AND REPAIR LLC. | H= | C | 09/21/2018 | no a/c | TED | TED | | H= | C | 5973426 |
WESTMAN HEATING AND REPAIR LLC. | HRR | C | 09/21/2018 | sealed combustion furnace, no a/c, electric water heater, unfinished basement (framing only), no doors to basement, 1 supply in basement | TED | TED | | HRR | C | 5973420 |
WESTMAN HEATING AND REPAIR LLC. | HO | C | 09/17/2018 | 10LB TEST OK. 30' OF 1/2" POLY PIPE WITH TRACER WIRE FROM TANK LOCATION TO REGULATOR LOCATION. | BILLS | BILLS | | HO | C | 5966675 |
WESTMAN HEATING AND REPAIR LLC. | HI | C | 09/17/2018 | 10LB TEST OK. 30' OF COUNTERSTRIKE EHD 25 FROM REGULATOR LOCATION TO FURNACE. | BILLS | BILLS | | HI | C | 5966672 |
DRUMMOND PLUMBING LLC | PWO | C | 09/21/2018 | line from pressure tank pit to house, yard hydrants backflow protected, certificate of potable water to scanning | TED | TED | | PWO | C | 5973435 |
DRUMMOND PLUMBING LLC | P= | C | 09/21/2018 | certificate of potable water to scanning, | TED | TED | | P= | C | 5973434 |
DRUMMOND PLUMBING LLC | PTO | C | 09/21/2018 | correction made | TED | TED | | PTO | C | 5973421 |
DRUMMOND PLUMBING LLC | PTO | P | 09/18/2018 | master shower drain back graded, need aav on furnace condensate drain, need to call in a pwo inspection (need to pot hole line from pressure tank pit to house ), note: unfinished basement, framed only, need certificate of potable water and backflow protection on yard hydrants by final | TED | TED | | PTO | P | 5969152 |
DRUMMOND PLUMBING LLC | PB | C | 07/06/2018 | ok, note: no water under footer or through wall at this time | TED | TED | | PB | C | 5895672 |
HOME RUN RESTORATIONS, INC. | XBS | T | 08/01/2018 | PAID (REC#1523094) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Revise basement to include garage, bearing wall and headers. | SHELLEY | SHELLEY | | XBS | T | 5920437 |