HOMEOWNER | B= | C | 11/25/2019 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 6409938 |
HOMEOWNER | B= | P | 03/21/2019 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 6139595 |
HOMEOWNER | BFT | C | 03/21/2019 | | NICK | NICK | | BFT | C | 6139584 |
HOMEOWNER | BIN | C | 11/01/2018 | WALLS AND CEILINGS | NATHAN | NATHAN | | BIN | C | 6013482 |
HOMEOWNER | BFN | C | 10/30/2018 | open excavation letter of file. | NATHAN | NATHAN | | BFN | C | 6010409 |
HOMEOWNER | BFR | C | 10/30/2018 | items corrected as inspected. | NATHAN | NATHAN | | BFR | C | 6010401 |
HOMEOWNER | BLA | C | 08/30/2018 | Lath OK / Entire perimeter of 2 story house | CHUCK | CHUCK | | BLA | C | 5950685 |
HOMEOWNER | BFT | P | 06/06/2018 | Strip footings not installed for exterior porches per approved plans, 2 12" wide 30" deep piers with 3 #4 vertical bars installed for back porch and 1 12" wide 30" deep with 3 #4 bars for front porch installed / Will need to splice plans to show new design / Still need open hole report / Grounding rod installed | NICK | NICK | | BFT | P | 5866688 |
HOMEOWNER | BFN | R | 04/20/2018 | no ufer | NATHAN | NATHAN | | BFN | R | 5823285 |
HOMEOWNER | BFT | P | 04/17/2018 | 1800 psf footer pad at interior will be at wall inspection | NATHAN | NATHAN | | BFT | P | 5819175 |
HOMEOWNER | E= | C | 03/19/2019 | no ac or no prewire | BRIAN | BRIAN | | E= | C | 6136913 |
HOMEOWNER | ER | C | 10/26/2018 | 20A circuit for bathroom receptacle installed, cans changed to IC rated where insulation will be installed / | MIGUEL | MIGUEL | | ER | C | 6007865 |
HOMEOWNER | ES | C | 10/26/2018 | Residential Overhead: 200A 3w new res ok to set meter / | MIGUEL | MIGUEL | | ES | C | 6007860 |
HOMEOWNER | ES | R | 10/18/2018 | Residential Overhead: 200A 3w using non service rated myers hub in factory opening of meter can---need to use factory hub w/ factory screws / | MIGUEL | MIGUEL | | ES | R | 5999165 |
HOMEOWNER | ER | R | 10/18/2018 | IR ufer, 2-10/3, no mcc-----need 20A circuit for bathroom receptacle on ground floor, cans are non IC rated, Discussed AFCI/GFCI/TR requirements with owner. note : 20A circuit for entire upstairs bathroom / | MIGUEL | MIGUEL | | ER | R | 5999143 |
HOMEOWNER | ES | R | 04/04/2018 | NEED TEMP POWER PERMIT -----WAITING FOR CSU TO LET ME KNOW ABOUT METER OR NO METER----100 AMP 3-W OVER HEAD | BRIAN | BRIAN | | ES | R | 5808090 |
HOMEOWNER | H= | C | 03/18/2019 | GAS FIREPLACE NOT INSTALLED AT TIME OF INSPECTION, GAS FIREPLACE WILL REQUIRE A SEPARATE PERMIT WHEN INSTALLED | MATTM | MATTM | | H= | C | 6135982 |
HOMEOWNER | H= | P | 03/07/2019 | BOILER VENT TERMINATION NEEDS TO BE COMPLETED TO MANUFACTURES INSTALLATION INSTRUCTIONS PAGES 23-25, BOILER VENT PIPES AT EXTERIOR NEED TO BE ASSEMBLED USING APPROVED PLUMBING METHODS WITH PRIMER AND GLUE, BOILER PRESSURE RELIEF DRAIN NEEDS TO BE AN APPROVED MATERIAL, GAS FIREPLACE NOT YET INSTALLED NOTES: DIRECT VENT BOILER FOR RADIANT HEAT WITH STORAGE TANK FOR POTABLE WATER, NO A/C | MATTM | MATTM | | H= | P | 6127183 |
HOMEOWNER | HC | C | 11/06/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 6017750 |
HOMEOWNER | HRR | C | 11/06/2018 | note: direct vent boiler for radiant heat with storage tank for hot potable water. | PAULO | PAULO | | HRR | C | 6017749 |
HOMEOWNER | HWP | C | 11/06/2018 | upper level hot water piping under live test, may cover piping at own risk. | PAULO | PAULO | | HWP | C | 6017746 |
HOMEOWNER | HRR | P | 10/29/2018 | need to mechanically fasten all bath fan exhaust duct joints and seal duct to fan exhaust collar. (STILL NEED AN HWP PRESSURE TEST AND INSPECTION TO UPPER LEVEL). note: direct vent boiler for radiant heat with storage tank for hot potable water. | PAULO | PAULO | | HRR | P | 6009113 |
O.M.A.G.M., INC. | HI | C | 10/23/2018 | 10# test ok. note: 3/4" main at 30' to 1- boiler and 1- cook top. | PAULO | PAULO | | HI | C | 6003254 |
HOMEOWNER | HWP | P | 06/06/2018 | Air test ok. | MARK | MARK | | HWP | P | 5866488 |
O.M.A.G.M., INC. | HI | P | 05/10/2018 | 10 lb test ok on 1" PS2 from mechanical to range. Still need to add boiler. | MARK | MARK | | HI | P | 5841303 |
O.M.A.G.M., INC. | HO | C | 05/10/2018 | 10 lb test ok on on 3/4" PE from future meter to fireplace. | MARK | MARK | | HO | C | 5841299 |
HOMEOWNER | P= | C | 03/20/2019 | corrections made | JOSEPHD | JOSEPHD | | P= | C | 6138032 |
HOMEOWNER | P= | P | 03/18/2019 | need to expose aav @ washer box, need hammer arrestor at dishwasher, main floor shower crossed, rest ok | JOSEPHD | JOSEPHD | | P= | P | 6136041 |
HOMEOWNER | PTO | C | 10/26/2018 | Correction made | SHANEN | SHANEN | | PTO | C | 6006788 |
HOMEOWNER | PTO | P | 10/25/2018 | Need to use approved primer on PVC joints, rest OK, AAV washer box, kitchen sink and second floor lav | SHANEN | SHANEN | | PTO | P | 6006630 |
HOMEOWNER | PB | C | 05/25/2018 | | SHANEN | SHANEN | | PB | C | 5855912 |
HOMEOWNER | XBS | T | 09/21/2018 | PAID (REC#1540046) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Provided pier details per inspector comments. | BPHILLIPS | BPHILLIPS | | XBS | T | 5973307 |