S. K. STEELE CONSTRUCTION COMPANY, INC. | B= | C | 09/20/2018 | no foundation components added no openex needed. a/c installed | NATHAN | NATHAN | | B= | C | 5971872 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | BLA | C | 07/10/2018 | | NICK | NICK | | BLA | C | 5898325 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | BIN | P | 06/18/2018 | Need ES report for spray foam used throughout / Insulation OK | NICK | NICK | | BIN | P | 5877817 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | BFR | P | 06/18/2018 | New Eng design on site for all framing items, need to splice into approved plans to complete frame | NICK | NICK | | BFR | P | 5877813 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | BFR | P | 05/31/2018 | address saddle at 14 LVL carrying 9 1/2" LVL at kitchen and address rafter bearing at rear wall of kitchen no headers and on interior slab, bolt at C8 channel with washer at splice, address headers at front wall that are concrete not per plan, okay to insulate | NATHAN | NATHAN | | BFR | P | 5861237 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | BFN | C | 05/31/2018 | EDIT 6-1 will need stamped open excavation, Engineers observation Letter on file / Foundation design on file / Soils report on file / | NATHAN | NATHAN | | BFN | C | 5861236 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | BFT | C | 05/31/2018 | Engineer letter for footing on file -- Open hole on file / | NATHAN | NATHAN | | BFT | C | 5861235 |
GADDIE ELECTRIC, INC. | E= | C | 09/19/2018 | receptacle added to right of range / | MIGUEL | MIGUEL | | E= | C | 5969975 |
GADDIE ELECTRIC, INC. | E= | R | 09/13/2018 | NO OUTLET ADDED TO RIGHT OF COOK TOP-----REMOVED DOOR TO GARAGE IN CORNER OF COUNTER INSTEAD / | MIGUEL | MIGUEL | | E= | R | 5964762 |
GADDIE ELECTRIC, INC. | E= | R | 08/28/2018 | NEED TO LAND THE GEC'S ON THE NEUTRAL BAR IN DISCONNECT---NEED ENCLOSED LIGHTS IN MASTER CLOSET---ADD OUTLET IN THE SPACE TO RIGHT OF THE COOK TOP-----40 AMP AC--OK | BRIAN | BRIAN | | E= | R | 5948605 |
GADDIE ELECTRIC, INC. | ES | C | 08/28/2018 | Residential Overhead: 150 AMP 3-W EXIST RES---OK NO ACTION NEEDED | BRIAN | BRIAN | | ES | C | 5948593 |
GADDIE ELECTRIC, INC. | ES | P | 08/20/2018 | Residential Underground: PRE RELEASE OK/ | GREGM | GREGM | | ES | P | 5938812 |
GADDIE ELECTRIC, INC. | EUG | C | 07/27/2018 | 2" pvc | TIMA | TIMA | | EUG | C | 5916176 |
GADDIE ELECTRIC, INC. | ER | C | 05/22/2018 | | BRIAN | BRIAN | | ER | C | 5852175 |
GADDIE ELECTRIC, INC. | ER | R | 05/17/2018 | NEED FEEDER OR RACEWAY FOR PANEL---IS THIS THE MAIN ?? IF SO CAN NOT HAVE IT ON INSIDE WALL ----UF IS NOT RATED TO BE IN CONCRETE WITH OUT SLEEVE --IT IS IN THE POOR-------ADD OUTLET ON OUTSIDE OF BACK DOOR---- | BRIAN | BRIAN | | ER | R | 5848605 |
PIKES PEAK PLUMBING, INC. | H= | C | 09/18/2018 | | MARK | MARK | | H= | C | 5968113 |
THE FURNACE GUY HEATING & COOLING | H= | C | 09/18/2018 | Vent has been corrected. | MARK | MARK | | H= | C | 5968112 |
THE FURNACE GUY HEATING & COOLING | H= | T | 09/17/2018 | PAID (REC#1537959): Vent still the same, not ready. Please make corrections before scheduling an inspection. Doors have been undercut. | MARK | MARK | | H= | T | 5966869 |
THE FURNACE GUY HEATING & COOLING | H= | T | 09/14/2018 | PAID (REC#1537453): Furnace vents do not meet mfg requirements. see pg 58,59,66. Bedroom doors need to be undercut for return air path as noted at lst final inspection. Too many trips, third inspection required fees apply. | MARK | MARK | | H= | T | 5965534 |
THE FURNACE GUY HEATING & COOLING | H= | P | 09/14/2018 | Performance test received. 9/14/18. | MARK | MARK | | H= | P | 5965129 |
THE FURNACE GUY HEATING & COOLING | H= | R | 09/10/2018 | Still do not have a completed HRR, not sure how or why a final was called in. Furnace vent is back graded and termination is too close to the gas regulator. Condenser pad needs to be min 3" above grade, I need to see a/c A coil specs as noted at rough. Need to see a supply in the laundry room, missing duct leak report, need to undercut bedroom doors for return air path. (Except master) Reinspaect all. | MARK | MARK | | H= | R | 5959538 |
PIKES PEAK PLUMBING, INC. | HI | C | 06/05/2018 | 10 lb test ok. Note: 3/4" main. Furnace, water heater and cook top. | MARK | MARK | | HI | C | 5865057 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 05/15/2018 | Missing heat to laundry, drop heat in master bedroom. By final need a/c coil specs, duct leak report. Note: Matching furnace is direct vented, need to verify a/c coil at re inspection or by final, has hi/lo grills for water heater combustion air. No osa per plans. Fireplace is solid fuel. | MARK | MARK | | HRR | P | 5845065 |
JOLLY PLUMBING & HEATING INC. | P= | C | 09/13/2018 | | TAYLOR | TAYLOR | | P= | C | 5963676 |
JOLLY PLUMBING & HEATING INC. | P= | P | 09/12/2018 | still need trap guard. | TAYLOR | TAYLOR | | P= | P | 5963196 |
JOLLY PLUMBING & HEATING INC. | P= | P | 09/11/2018 | waive trip fee, still missing trap guard at laundry room, support water service across bottom of wall, rest ok. | TAYLOR | TAYLOR | | P= | P | 5961757 |
JOLLY PLUMBING & HEATING INC. | P= | R | 09/10/2018 | no hot water, can not crimp HDPE pipe in mech room, need trap guard at laundry room, re- inspect all. | TAYLOR | TAYLOR | | P= | R | 5960493 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 05/09/2018 | Corrections made | SHANEN | SHANEN | | PTO | C | 5839644 |
JOLLY PLUMBING & HEATING INC. | PB | C | 05/07/2018 | | SHANEN | SHANEN | | PB | C | 5837198 |
JOLLY PLUMBING & HEATING INC. | PTO | P | 05/07/2018 | Low test on water distribution, need nail protection throughout, rest OK, AAV all | SHANEN | SHANEN | | PTO | P | 5837195 |
PIKES PEAK PLUMBING, INC. | XMS | T | 09/10/2018 | PAID (REC#1535349): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: see plan review approval comments | DALEH | DALEH | | XMS | T | 5959464 |
S. K. STEELE CONSTRUCTION COMPANY, INC. | XBS | P | 09/04/2018 | PLAN SPLICE: (No Fee) by: DANM for Construction: Updated insulation information on sections | DANM | DANM | | XBS | P | 5954506 |