MERRITT GENERAL CONTRACTORS, INC. | B= | C | 11/27/2018 | zoning complete | JANE | JANE | | B= | C | 6034613 |
MERRITT GENERAL CONTRACTORS, INC. | B= | P | 11/07/2018 | Temp CO: Pending the zoning final ( Expires: 12/7/2018 12:00:00 AM) | RITA | RITA | | B= | P | 6019217 |
MERRITT GENERAL CONTRACTORS, INC. | B= | P | 11/02/2018 | Building Final OK pending other Finals. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection HD= by HEALTHDEPT is not Completed yet, ANYTHING HVAC, LLC. Mechanical Final Inspection is not Completed yet, BRUNO'S MECHANICAL INC. Mechanical Final Inspection is not Completed yet, SYSTEMS ELECTRIC, INC. Electrical Final Inspection is not Completed yet. | RICHB | RICHB | | B= | P | 6014837 |
MERRITT GENERAL CONTRACTORS, INC. | BFR | P | 07/19/2018 | Interior shear OK / hold downs OK / still need Open Hole / plans reviewed onsite | RICHB | RICHB | | BFR | P | 5908673 |
MERRITT GENERAL CONTRACTORS, INC. | BFR | P | 06/05/2018 | Still need Open Hole / all exterior shear wall sheathing OK - still need to inspect hold-downs when ready / roof sheathing OK / plans reviewed onsite | RICHB | RICHB | | BFR | P | 5864833 |
MERRITT GENERAL CONTRACTORS, INC. | BFR | P | 06/01/2018 | Need Open Hole / shear wall Type 3 at South elevation - OSB sheathing OK, rest of wall not ready / discussed "trusses pending" status / discussed accessible elements / discussed hood wall framing requirements | RICHB | RICHB | | BFR | P | 5861756 |
MERRITT GENERAL CONTRACTORS, INC. | BFN | P | 04/10/2018 | Need Open Hole observation / no plans on file - inspected using cropped plans onsite / formwork & reinforcement OK per plans onsite / need plot plan to verify location | RICHB | RICHB | | BFN | P | 5812396 |
SYSTEMS ELECTRIC, INC. | E= | C | 11/05/2018 | rtu 1 --- 90 ---- rtu 2---50 --- cooler condencer's 15 amp fused at the condencer | CRAIGS | CRAIGS | | E= | C | 6016082 |
SYSTEMS ELECTRIC, INC. | E= | P | 10/18/2018 | all the work area --ok --bathrooms -ok---rtu/ roof ok----------------need 15 amp breaker one EF ---need 15 amp fuses in cooler and freezer ----need disconnects for blower fans in cooler and freezer----panel sch--panel filler---- | BRIAN | BRIAN | | E= | P | 5998981 |
SYSTEMS ELECTRIC, INC. | ER | P | 10/05/2018 | kitchen and food prep are above ceiling OK | CRAIGS | CRAIGS | | ER | P | 5987982 |
SYSTEMS ELECTRIC, INC. | ES | C | 10/02/2018 | Commercial Service: 400 AMP 4-W ---OK TO SET CT'S AND METER-----------------------------NOTE NEED TO REPLACE THE METAL LB WITH PLASTIC BY FINAL---- | BRIAN | BRIAN | | ES | C | 5983180 |
SYSTEMS ELECTRIC, INC. | ES | R | 10/01/2018 | Commercial Service: remove equipment ground from ct can to the panel ---make sure there are prints on site | CRAIGS | CRAIGS | | ES | R | 5982237 |
SYSTEMS ELECTRIC, INC. | EUG | P | 09/20/2018 | light poles and ditches west side OK | CRAIGS | CRAIGS | | EUG | P | 5971937 |
SYSTEMS ELECTRIC, INC. | EUG | P | 09/14/2018 | EAST SIDE POLE LIGHTS AND SIGN CONDUITS ok | CRAIGS | CRAIGS | | EUG | P | 5965384 |
SYSTEMS ELECTRIC, INC. | ER | P | 07/30/2018 | Hardlids: bathrooms, vestibule p | GARYL | GARYL | | ER | P | 5918201 |
SYSTEMS ELECTRIC, INC. | ER | P | 07/20/2018 | rest of walls okay | GARYL | GARYL | | ER | P | 5909914 |
SYSTEMS ELECTRIC, INC. | ER | P | 07/12/2018 | walls only, these walls not inspected, not ready: bathroom walls, drive up window a west side | GARYL | GARYL | | ER | P | 5901003 |
SYSTEMS ELECTRIC, INC. | EUG | P | 05/10/2018 | all slab work on inside of building | GARYL | GARYL | | EUG | P | 5841764 |
BRUNO'S MECHANICAL INC. | H= | C | 11/07/2018 | ALL FINAL CONNECTIONS ARE COMPLETE WITH TIE DOWNS WHERE NEEDED | JERRYF | JERRYF | | H= | C | 6018933 |
ANYTHING HVAC, LLC. | H= | C | 11/05/2018 | TAB REPORT RECEIVED - PERMIT CORRECTION MADE | JERRYF | JERRYF | | H= | C | 6015335 |
ANYTHING HVAC, LLC. | H= | P | 11/02/2018 | PARTIAL PENDING TAB REPORT AND ADDING 2 WATER HEATER VENTS TO PERMIT NOTES: AFTER CONSULT WITH SENIOR INSPECTOR NO HAND RAILS ARE REQUIRED | JERRYF | JERRYF | | H= | P | 6013790 |
ANYTHING HVAC, LLC. | H= | P | 11/01/2018 | DOOR HAS BEEN UNDER CUT AND GREASE FAN ACCESS OK - STILL NEED OTHER NOTES ADDRESSED | JERRYF | JERRYF | | H= | P | 6013375 |
ALNOR INC. | H= | C | 11/01/2018 | ICE MAKER AND CONDENSER | JERRYF | JERRYF | | H= | C | 6013370 |
ANYTHING HVAC, LLC. | H= | P | 10/30/2018 | PARTIAL PENDING THE FOLLOWING - TAB REPORT - SAFETY RAILS INSTALLED AT LARGE RTU AND EF 2 - UNDER CUT RESTROOM DOOR - CORRECT ACCESS TO EF2 FOR CLEANING - ADD 2 WATER HEATER VENTS TO PERMIT NOTES: INTERLOCKS ARE COMPLETE | JERRYF | JERRYF | | H= | P | 6010921 |
ANYTHING HVAC, LLC. | HV | C | 10/30/2018 | WATER HEATER VENTS | JERRYF | JERRYF | | HV | C | 6010918 |
ANYTHING HVAC, LLC. | H= | P | 09/26/2018 | ABOVE CEILING SA / RA AND RESTROOM EXHAUST OK - STILL NEED ALL CONTROLS - ROOF INSPECTION - INTERLOCKS - TAB REPORT - WATER HEATER MANUAL TO VERIFY VENTING | JERRYF | JERRYF | | H= | P | 5976716 |
ANYTHING HVAC, LLC. | HD | P | 09/10/2018 | LIGHT TEST OK ON 2 GREASE DUCTS OK FOR WRAP - CHECK ACCESS DOOR AT FUTURE INSPECTION | JERRYF | JERRYF | | HD | P | 5959894 |
ANYTHING HVAC, LLC. | HD | P | 08/15/2018 | GREASE DUCT LIGHT TEST OK ON 2 4' SECTIONS WITH 1 ELBOW - PERFORMED ON GROUND - STILL NEED ALL FINAL CONNECTIONS | JERRYF | JERRYF | | HD | P | 5934765 |
ANYTHING HVAC, LLC. | HD | P | 08/07/2018 | LIGHT TEST ON GREASE DUCT DROP FOR FAN OK FOR WRAP - HAD CONSULT ON PIZZA OVEN AND FRYER CLEARANCES TO WALLS | JERRYF | JERRYF | | HD | P | 5926416 |
BRUNO'S MECHANICAL INC. | HC | C | 07/19/2018 | RELEASE METER | JERRYF | JERRYF | | HC | C | 5908453 |
BRUNO'S MECHANICAL INC. | HI | C | 07/19/2018 | PRESSURE TEST AND PIPING OK PER PLAN / LINE TO PIZZA OVEN HAS BEEN UP SIZED TO 11/2" - AT FINAL VERIFY AND FINAL CONNECTIONS AND TIE DOWNS | JERRYF | JERRYF | | HI | C | 5908443 |
ANYTHING HVAC, LLC. | HD | P | 06/27/2018 | HOOD WALL FOR HOOD #1 OK FOR ZERO CLEARANCE HOOD - WILL VERIFY HOOD WALL #2 WHEN CONTRACTOR HAS INSTALL MANUAL FOR APPLIANCE UNDER HOOD HAS COMBUSTIBLE PIPING IN WALL - WILL NEED TO VERIFY CLEARANCES AT WALLS FROM APPLIANCES AT FUTURE INSPECTION - ((((ABOVE CEILING SA MAINS AND RUN OUTS OK FOR RTU 1 | JERRYF | JERRYF | | HD | P | 5887566 |
BRUNO'S MECHANICAL INC. | P= | C | 10/29/2018 | Ok. | DANR | DANR | | P= | C | 6008460 |
BRUNO'S MECHANICAL INC. | PTO | C | 10/29/2018 | Correction made. | DANR | DANR | | PTO | C | 6008455 |
BRUNO'S MECHANICAL INC. | P= | P | 10/25/2018 | Received letter from engineer for PVC and Service reduction. | JACK | JACK | | P= | P | 6005599 |
BRUNO'S MECHANICAL INC. | P= | P | 10/19/2018 | Need contractor on site for next inspection - to many items to list left list with G.C. - need PTO complete and all plan piping changes splices in - need material approval, RE-INSPECT ALL. | DANR | DANR | | P= | P | 6000002 |
BRUNO'S MECHANICAL INC. | PTO | P | 07/30/2018 | Need approved plans on site, need approval for pex and pvc piping, need approval for venting changes to aav at bar, vtr to close to air intake for rtu, cover at own risk. Note: at final check water entry and water heaters. | DANR | DANR | | PTO | P | 5917447 |
BRUNO'S MECHANICAL INC. | PTO | P | 06/15/2018 | This inspection for dwv and domestic water in wall and over head from bathrooms North, test ok, need engineer approval for pvc (dwv) and pex (domestic water) drawings P8.01 shows L copper (domestic water) and cast (dwv), need engineer approval for changing in ceiling tempering valves per drawing to under sink point of use, cover at own risk. Note: still need to check water entry and water heaters. | DANR | DANR | | PTO | P | 5875688 |
BRUNO'S MECHANICAL INC. | PB | C | 05/07/2018 | Test ok, Note: Need clean outs on horizontal dry vents, need approved drawings on site. | DANR | DANR | | PB | C | 5837357 |
BRUNO'S MECHANICAL INC. | PB | P | 04/30/2018 | still no approved plans on site, proceeded @ your own risk, ok for deep base risers @ g.w. and s.s. **STILL NEED LATERALS AND G.I. VENTS RAN INTO BLDG** | JOHNS | JOHNS | | PB | P | 5830626 |
BRUNO'S MECHANICAL INC. | PB | P | 04/17/2018 | no approved plans on site or in computer, cover @ your own risk, ok for s.s, g.w, and 1" water stubbed into bldg. note: outside grease interceptor | JOHNS | JOHNS | | PB | P | 5818560 |