COLORADO CUSTOM CONSTRUCTION LLC | B= | R | 11/16/2018 | Carbon monoxide alarms needed outside bedrooms / Provide paperwork from footer inspection / complete electrical and plumbing inspections. Additional Inspections Required (computer generated): COS PLUMBING LLC Plumbing Final Inspection is not Completed yet, TITAN ELECTRIC LLC Electrical Final Inspection is not Completed yet. | SHAUN | SHAUN | | B= | R | 6027917 |
COLORADO CUSTOM CONSTRUCTION LLC | BFT | P | 10/29/2018 | Center post footing pad inspection- Observed 24" x 24" x 8" deep footing form / Provide approved paperwork on size requirement of footing pad / Contractor states Geoquest stated 8" on depth / Inspection is partial pending approved paperwork | SHAUN | SHAUN | | BFT | P | 6008897 |
COLORADO CUSTOM CONSTRUCTION LLC | BIN | P | 07/24/2018 | Insulation OK pending frame complete | NICK | NICK | | BIN | P | 5911790 |
COLORADO CUSTOM CONSTRUCTION LLC | BFR | P | 07/20/2018 | Roof framing OK / Need to draft stop throughout / Need to inspect point load and pad at center of new roof beam per approved plans, not installed at time of inspection / Reviewed smokes and CO's / Need electrical complete | NICK | NICK | | BFR | P | 5909149 |
COLORADO CUSTOM CONSTRUCTION LLC | BFR | P | 06/29/2018 | Floor framing OK per design / Need to attach electrical permit / Reviewed smokes and CO's / Still need inspect all other framing | NICK | NICK | | BFR | P | 5889808 |
TITAN ELECTRIC LLC | E= | C | 11/20/2018 | pictures accepted of closed boxes / | MIGUEL | MIGUEL | | E= | C | 6030300 |
TITAN ELECTRIC LLC | E= | R | 11/16/2018 | storage area has 2 open boxes, need blank plates, ok to upload pics | JOHNN | JOHNN | | E= | R | 6028505 |
TITAN ELECTRIC LLC | ER | C | 07/23/2018 | | JOHNN | JOHNN | | ER | C | 5910373 |
TITAN ELECTRIC LLC | ER | R | 07/18/2018 | grd 3 plastic 3/0 boxes, ok to upload pics, do not put outlets above baseboard heaters, ---------front gable is existing except light, | JOHNN | JOHNN | | ER | R | 5907288 |
COS PLUMBING LLC | P= | C | 12/03/2018 | correction made see images anti-siphon | JOSEPHD | JOSEPHD | | P= | C | 6040620 |
COS PLUMBING LLC | P= | P | 11/16/2018 | Need anti-siphon protection for hand held sprayer at tub, rest OK | SHANEN | SHANEN | | P= | P | 6027794 |
COS PLUMBING LLC | PTO | C | 07/19/2018 | Corrections made, image received | SHANEN | SHANEN | | PTO | C | 5907447 |
COS PLUMBING LLC | PTO | P | 07/17/2018 | Re-grade trap arm at left lav, attach electrical permit per previous notes, water and drain tie-ins OK, AAV lavs | SHANEN | SHANEN | | PTO | P | 5904808 |
COS PLUMBING LLC | PTO | P | 06/15/2018 | Attach electrical permit to building permit, under floor DWV and water distribution OK, check tie-ins at next PTO inspection | SHANEN | SHANEN | | PTO | P | 5875964 |