VICEROY DEVELOPMENT, INC. | B= | C | 11/21/2018 | with a/c | NATHAN | NATHAN | | B= | C | 6032416 |
VICEROY DEVELOPMENT, INC. | BLA | C | 08/27/2018 | | NATHAN | NATHAN | | BLA | C | 5946738 |
VICEROY DEVELOPMENT, INC. | BIN | C | 08/20/2018 | | NATHAN | NATHAN | | BIN | C | 5939631 |
VICEROY DEVELOPMENT, INC. | BFR | C | 08/16/2018 | | NATHAN | NATHAN | | BFR | C | 5936633 |
VICEROY DEVELOPMENT, INC. | BFR | R | 08/15/2018 | canceled not ready | NATHAN | NATHAN | | BFR | R | 5935188 |
VICEROY DEVELOPMENT, INC. | BSP | P | 08/09/2018 | front deck pier okay | NATHAN | NATHAN | | BSP | P | 5929236 |
VICEROY DEVELOPMENT, INC. | BFT | C | 07/19/2018 | openex | NATHAN | NATHAN | | BFT | C | 5907403 |
VICEROY DEVELOPMENT, INC. | BFN | C | 07/19/2018 | soils | NATHAN | NATHAN | | BFN | C | 5907402 |
VICEROY DEVELOPMENT, INC. | BSP | P | 05/22/2018 | 3rd floor facing rated wall and rim okay | NATHAN | NATHAN | | BSP | P | 5852164 |
VICEROY DEVELOPMENT, INC. | BSP | P | 05/18/2018 | Inspection for interior side of 5/8 sheet rock per GA file NO WP 8105 for 2nd floor / Rock and nail pattern OK / Still need to inspect unit side of wall once rock installed | NICK | NICK | | BSP | P | 5849584 |
VICEROY DEVELOPMENT, INC. | BSP | P | 05/15/2018 | Inspection for 1st floor partition party wall / 5/8 rock on interior side of both walls OK / Nail pattern OK per GA file NO WP 8105 / Still need to inspect exterior side of rated walls 1st floor | NICK | NICK | | BSP | P | 5845666 |
VICEROY DEVELOPMENT, INC. | BFT | P | 05/15/2018 | Letter of observation on file from architect / Still need open hole / Still need soils report | NICK | NICK | | BFT | P | 5844732 |
VICEROY DEVELOPMENT, INC. | BFN | P | 05/15/2018 | Letter of observation on file from architect / Still need open hole / Still need soils report | NICK | NICK | | BFN | P | 5844731 |
VICEROY DEVELOPMENT, INC. | BFI | P | 04/27/2018 | 2" rigid 30" deep | NATHAN | NATHAN | | BFI | P | 5829682 |
WINTERS ELECTRIC, INC. | E= | C | 11/01/2018 | CORRECTIONS MADE----20A A/C OK---MCA 14.3, MOCP 25 / | MIGUEL | MIGUEL | | E= | C | 6012988 |
WINTERS ELECTRIC, INC. | E= | R | 10/31/2018 | 30A A/C ---MCA 14.3, MOCP 25 ---change breaker-----need power to upstairs bathroom receptacle between sinks / | MIGUEL | MIGUEL | | E= | R | 6012375 |
WINTERS ELECTRIC, INC. | ES | C | 08/10/2018 | Residential Underground: 150 AMP 3-W NEW RES ----OK TO SET METER---- | BRIAN | BRIAN | | ES | C | 5930308 |
WINTERS ELECTRIC, INC. | ER | C | 08/10/2018 | NO UFER ACCESS NEEDED--NO CV--- | BRIAN | BRIAN | | ER | C | 5930303 |
THE FURNACE GUY HEATING & COOLING | H= | C | 11/13/2018 | note: slab on grade, high outside combustion air to mechanical room, outside air to return, direct vent furnace, indirect vent water heater, a/c complete, received performance test, received change of equipment letter for furnace and coil. | PAULO | PAULO | | H= | C | 6023956 |
THE FURNACE GUY HEATING & COOLING | H= | P | 11/13/2018 | need installation manual for water heater on site for inspection, VERIFY IF CONDENSATE SHOULD BE INSTALLED TO WATER HEATER VENT. note: slab on grade, high outside combustion air to mechanical room, outside air to return, direct vent furnace, indirect vent water heater, a/c complete, received performance test, received change of equipment letter for furnace and coil. | PAULO | PAULO | | H= | P | 6023414 |
THE FURNACE GUY HEATING & COOLING | H= | P | 11/12/2018 | need to address the following-- installation manual for water heater on site for inspection, change of equipment letter for furnace and coil. VERIFY IF CONDENSATE SHOULD BE INSTALLED TO WATER HEATER VENT. note: slab on grade, high outside combustion air to mechanical room, outside air to return, direct vent furnace, indirect vent water heater, a/c complete, received performance test. | PAULO | PAULO | | H= | P | 6022743 |
THE FURNACE GUY HEATING & COOLING | H= | P | 11/12/2018 | need to address the following-- installation manual for water heater on site for inspection, water heater vent termination per manufactures installations, secondary drain or emergency shut off to coil (structural floor), change of equipment letter for furnace and coil. VERIFY IF CONDENSATE SHOULD BE INSTALLED TO WATER HEATER VENT. note: slab on grade, high outside combustion air to mechanical room, outside air to return, direct vent furnace, indirect vent water heater, a/c complete, received performance test. | PAULO | PAULO | | H= | P | 6022454 |
THE FURNACE GUY HEATING & COOLING | H= | P | 11/08/2018 | need to address the following-- installation manual for water heater on site for inspection, water heater vent termination per manufactures installations, secondary drain or emergency shut off to coil (structural floor), change of equipment letter for furnace and coil, performance test. VERIFY IF CONDENSATE SHOULD BE INSTALLED TO WATER HEATER VENT. note: slab on grade, high outside combustion air to mechanical room, outside air to return, direct vent furnace, indirect vent water heater, a/c complete. | PAULO | PAULO | | H= | P | 6020593 |
THE FURNACE GUY HEATING & COOLING | HC | C | 08/13/2018 | RELEASE METER | MARK | MARK | | HC | C | 5931739 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 08/13/2018 | Corrections made, still neew performance test and equipment change letter by final. | MARK | MARK | | HRR | C | 5931729 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 08/08/2018 | Need to pan off return on 2nd level at soffit, dryer vent must be supported every 4', missing bath fan on 2nd level and need to connect bath exhaust on 3rd level. By final need an equipment change letter for the furnace and coil. Performance test by final. Note: Furnace is direct vent, 6" high to outdoors for the water heater. a/c coil and line set, No osa | MARK | MARK | | HRR | P | 5928339 |
SPRINGS GAS, INC. | HI | C | 08/03/2018 | 10 LB Test okay. 1" Main. 1 Furnace. 1 Water heater. 1 Range. | RANDYB | RANDYB | | HI | C | 5923656 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | C | 11/06/2018 | Corrections made | SHANEN | SHANEN | | P= | C | 6016759 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | P | 11/05/2018 | Need to cap open laundry sink drain, repair leak above powder room, rest OK | SHANEN | SHANEN | | P= | P | 6015791 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | T | 11/02/2018 | PAID (REC#1553627): Install expansion device, cap open laundry sink drain, no water at left master lav, loose shower arm at master, rest OK, laundry sink rough-in only | SHANEN | SHANEN | | P= | T | 6014041 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | L | 11/01/2018 | Field canceled | SHANEN | SHANEN | | P= | L | 6012728 |
TRADITIONAL PLUMBING AND HEATING LLC | P= | R | 10/31/2018 | Not ready, WAIVED TRIP FEE` | SHANEN | SHANEN | | P= | R | 6011619 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | C | 07/19/2018 | AAV quad drain | SHANEN | SHANEN | | PTO | C | 5907569 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | R | 07/18/2018 | Not ready, no test or nail protection, waived trip fee | SHANEN | SHANEN | | PTO | R | 5906204 |
TRADITIONAL PLUMBING AND HEATING LLC | PTO | L | 07/17/2018 | Field canceled | SHANEN | SHANEN | | PTO | L | 5904706 |
TRADITIONAL PLUMBING AND HEATING LLC | PB | C | 05/04/2018 | | TAYLOR | TAYLOR | | PB | C | 5836720 |
TRADITIONAL PLUMBING AND HEATING LLC | PB | P | 05/02/2018 | stub in's ok. | TAYLOR | TAYLOR | | PB | P | 5833260 |
VICEROY DEVELOPMENT, INC. | XBS | T | 10/25/2018 | PAID (REC#1550923) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Revised GA listed assembly for party wall. | BPHILLIPS | BPHILLIPS | | XBS | T | 6006147 |