HI-POINT HOME BUILDERS, LLC | B= | C | 05/08/2019 | All other required Final inspections are complete. (This is a computer generated result) | PARKER | PARKER | | B= | C | 6192106 |
HI-POINT HOME BUILDERS, LLC | B= | P | 05/03/2019 | Items corrected. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | PARKER | PARKER | | B= | P | 6186416 |
HI-POINT HOME BUILDERS, LLC | B= | P | 04/30/2019 | Need to install graspable hand rail for garage steps / Over 4" opening at front porch guard rail / Need to finish nailing straps for stair stringers at front exterior entry steps / Need to install backing for underside of fire place pop out at exterior / All other elements for final OK -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 6182862 |
HI-POINT HOME BUILDERS, LLC | BSP | P | 04/05/2019 | 2 12" piers dug at front of house for landing, not on approved plans / Need to splice into approved plans | NICK | NICK | | BSP | P | 6156447 |
HI-POINT HOME BUILDERS, LLC | BFR | C | 01/07/2019 | Wood in beam pocket replaced with steel | SHAUN | SHAUN | | BFR | C | 6070464 |
HI-POINT HOME BUILDERS, LLC | BIN | P | 01/04/2019 | Insulation OK pending frame complete | NICK | NICK | | BIN | P | 6069182 |
HI-POINT HOME BUILDERS, LLC | BFR | P | 01/04/2019 | Still need to remove wood from beam pocket / All other items completed / Unfinished basement | NICK | NICK | | BFR | P | 6069169 |
HI-POINT HOME BUILDERS, LLC | BIN | R | 01/03/2019 | Need frame items completed ( clean out B vent chase and under fireplace and mechanical chase main level and wood in beam pockets ) / All insulation OK pending frame complete | NICK | NICK | | BIN | R | 6067429 |
HI-POINT HOME BUILDERS, LLC | BFR | P | 12/28/2018 | Need to clean out b vent chase / Still need to remove wood from beam pockets / Eng on file for use of H2.5A hardware in place of H2.5T / All other framing items completed / OK to insulate | NICK | NICK | | BFR | P | 6064999 |
HI-POINT HOME BUILDERS, LLC | BFR | R | 12/21/2018 | Unable to open plans on computer / No truss calcs on site for inspection / Need to inspect trusses / Need to install double H2.5T hangers for A06 both ends / Approved plans call for H2.5T hangers for all trusses, H2.5A hangers used for some trusses throughout, will need to install H2.5T hangers per approved Eng design or provide letter for use of H2.5A / Need to install LUS26 for stair landing / Need to install SDS screws for stair landing ledger / Need to remove wood from beam pockets / Need to strap all 4 corners of basement stair landing or install wedge anchors for ledger per approved plans | NICK | NICK | | BFR | R | 6061327 |
HI-POINT HOME BUILDERS, LLC | BIN | P | 12/21/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 6060161 |
HI-POINT HOME BUILDERS, LLC | BFD | C | 11/28/2018 | Image of drain tie in on file | NICK | NICK | | BFD | C | 6035991 |
HI-POINT HOME BUILDERS, LLC | BSP | P | 11/26/2018 | Eng on file for framing of headers in basement | NICK | NICK | | BSP | P | 6033183 |
HI-POINT HOME BUILDERS, LLC | BFD | P | 11/26/2018 | 3rd party observation on file for foundation drain / Still need to inspect connection to street or provide image of connection to street / | NICK | NICK | | BFD | P | 6033179 |
HI-POINT HOME BUILDERS, LLC | BSP | P | 09/25/2018 | front porch and posts, exterior straps at A note per plan | NATHAN | NATHAN | | BSP | P | 5976406 |
HI-POINT HOME BUILDERS, LLC | BFT | C | 05/21/2018 | Open hole on file / Eng letter of observation on file / #1800psf / Drain usable / Isolate and float / 10% grade | NICK | NICK | | BFT | C | 5850345 |
HI-POINT HOME BUILDERS, LLC | BFN | C | 05/21/2018 | Eng letter of observation on file / Soils on file | NICK | NICK | | BFN | C | 5850342 |
HI-POINT HOME BUILDERS, LLC | BFN | P | 05/04/2018 | Foundation design on file / Still need open hole, soils and Eng observation / Design is for #1500psf | NICK | NICK | | BFN | P | 5835718 |
HI-POINT HOME BUILDERS, LLC | BFD | P | 04/26/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5827984 |
HI-POINT HOME BUILDERS, LLC | BFT | P | 04/26/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5827983 |
HI-POINT HOME BUILDERS, LLC | BFN | P | 04/26/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5827982 |
ROWAN ELECTRIC LLC | E= | C | 03/27/2019 | A/C pre-wire / unfinished basement / | MIGUEL | MIGUEL | | E= | C | 6146028 |
ROWAN ELECTRIC LLC | ER | C | 12/07/2018 | fireplace ok / | MIGUEL | MIGUEL | | ER | C | 6046818 |
ROWAN ELECTRIC LLC | ES | C | 11/29/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter, new res | JOHNN | JOHNN | | ES | C | 6037521 |
ROWAN ELECTRIC LLC | ER | R | 11/29/2018 | fire place not installed,-------------------------no mcc,ir ufer,#6al, | JOHNN | JOHNN | | ER | R | 6037510 |
GENE'S HEATING AND AIR LLC | H= | C | 04/26/2019 | RECEIVED IMAGE OF CORRECTION FROM CONTRACTOR, SEE IMAGES. NOTES: UNFINISHED BASEMENT (3 SUPPLY 1 RETURN), OUTSIDE AIR TO FURNACE RETURN W/MOTORIZED DAMPER, DIRECT VENT FURNACE, A/C ROUGH LINESET, 1 FIREPLACE | MATTM | MATTM | | H= | C | 6178825 |
GENE'S HEATING AND AIR LLC | H= | P | 04/24/2019 | MISSING RETURN AIR PATH IN BASEMENT, OK TO ATTACH PICTURE TO NEXT INSPECTION REQUEST. NOTES: UNFINISHED BASEMENT (3 SUPPLY), OUTSIDE AIR TO FURNACE RETURN W/MOTORIZED DAMPER, DIRECT VENT FURNACE, A/C ROUGH LINESET, 1 FIREPLACE | MATTM | MATTM | | H= | P | 6177322 |
GENE'S HEATING AND AIR LLC | HC | C | 12/20/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 6060036 |
GENE'S HEATING AND AIR LLC | HRR | C | 12/20/2018 | NEEDED BY FINAL-- CLEARANCE TO COMBUSTIBLES FROM B-VENT IN BASEMENT. note: unfinished basement, outside air to return, direct vent furnace, no a/c. | PAULO | PAULO | | HRR | C | 6060035 |
GENE'S HEATING AND AIR LLC | HRR | R | 12/19/2018 | no access (locked) to home. | PAULO | PAULO | | HRR | R | 6058374 |
GENE'S HEATING AND AIR LLC | HRR | P | 12/13/2018 | missing supply air duct to upper level hallway per plans. NEEDED BY FINAL-- CLEARANCE TO COMBUSTIBLES FROM B-VENT IN BASEMENT. note: unfinished basement, outside air to return, direct vent furnace, no a/c. | PAULO | PAULO | | HRR | P | 6052462 |
PRECISION PLUMBING | HI | C | 12/06/2018 | 10# test ok. note: 1 1/4" main at 60' to 1- furnace, 1- water heater, 1- range, 1- fire place and 1- bbq. | PAULO | PAULO | | HI | C | 6045251 |
PRECISION PLUMBING | P= | C | 04/12/2019 | note: unfinished basement, pvb installed | JOSEPHD | JOSEPHD | | P= | C | 6163880 |
PRECISION PLUMBING | PTO | C | 11/02/2018 | Correction made | SHANEN | SHANEN | | PTO | C | 6014134 |
PRECISION PLUMBING | PTO | R | 10/25/2018 | Cannot wet vent water closet on second floor with kitchen sink on main level, correct and re-test, rest OK, unfinished basement, irrigation | SHANEN | SHANEN | | PTO | R | 6006631 |
PRECISION PLUMBING | PB | C | 06/19/2018 | | SHANEN | SHANEN | | PB | C | 5878486 |
HI-POINT HOME BUILDERS, LLC | XBS | T | 04/09/2019 | PAID (REC#1589454) PLAN SPLICE FEE: $50 by: DANM for Construction: Add landing for stairs | DANM | DANM | | XBS | T | 6160771 |